Intraoperative detection of parathyroid glands by autofluorescence identification using image-based system: report of 15 cases
Abstract Background A detection of parathyroid glands by the evaluation of their autofluorescence in the near-infrared spectrum is considered as a promising tool in addition to their visual verification. The aim of this study was to evaluate the role of near-infrared autofluorescence application by...
Main Authors: | Maksym Gorobeiko, Andrii Dinets |
---|---|
Format: | Article |
Language: | English |
Published: |
BMC
2021-08-01
|
Series: | Journal of Medical Case Reports |
Subjects: | |
Online Access: | https://doi.org/10.1186/s13256-021-03009-8 |
Similar Items
-
Parathyroid Autofluorescence—How Does It Affect Parathyroid and Thyroid Surgery? A 5 Year Experience
by: Roland Ladurner, et al.
Published: (2019-07-01) -
Intraoperative Autofluorescence and Indocyanine Green Angiography for the Detection and Preservation of Parathyroid Glands
by: Marco Stefano Demarchi, et al.
Published: (2020-03-01) -
Parathyroid identification by autofluorescence – preliminary report on five cases of surgery for primary hyperparathyroidism
by: Carlos Serra, et al.
Published: (2019-08-01) -
The Accuracy of Near Infrared Autofluorescence in Identifying Parathyroid Gland During Thyroid and Parathyroid Surgery: A Meta-Analysis
by: Bin Wang, et al.
Published: (2021-06-01) -
Intraoperative identification of parathyroid glands by autofluorescence on total thyroidectomy – Does it really reduces post-operative hypocalcemia?
by: Carlos Serra, et al.