OPTIMALISASI DIAMETER KAWAT UNTUK KOMPONEN SENSOR SUHU RENDAH BERBASIS SUSEPTIBILITAS

<p>Research has been carried out low-temperature sensors based magnetic susceptibility. The study was conducted in order to obtain the most appropriate wire diameter to be used as a low temperature sensor. As the sample used three solenoid with a wire diameter of 0.10 mm; 0.15 mm; and 0.20 mm....

Full description

Bibliographic Details
Main Authors: HALLEYNA WIDYASARI, MOH. TOIFUR
Format: Article
Language:Indonesian
Published: Lembaga Penelitian Universitas Indraprasta PGRI 2016-09-01
Series:Faktor Exacta
Online Access:http://journal.lppmunindra.ac.id/index.php/Faktor_Exacta/article/view/787
id doaj-793262367a9b4089bf1ffccf4c8a8831
record_format Article
spelling doaj-793262367a9b4089bf1ffccf4c8a88312020-11-25T01:52:53ZindLembaga Penelitian Universitas Indraprasta PGRIFaktor Exacta1979-276X2502-339X2016-09-019210911310.30998/faktorexacta.v9i2.787662OPTIMALISASI DIAMETER KAWAT UNTUK KOMPONEN SENSOR SUHU RENDAH BERBASIS SUSEPTIBILITASHALLEYNA WIDYASARIMOH. TOIFUR<p>Research has been carried out low-temperature sensors based magnetic susceptibility. The study was conducted in order to obtain the most appropriate wire diameter to be used as a low temperature sensor. As the sample used three solenoid with a wire diameter of 0.10 mm; 0.15 mm; and 0.20 mm. Experiments performed using the room temperature was varied from 157K until 253K. Data collection was performed on the multimaster current, the magnetic field induced by the gaussmeter, medium temperature with a digital thermocouple. Medium magnetic susceptibility values obtained by linear regression of data electric current and magnetic induction. Based on the analysis of the data it can be concluded solenoid with a wire diameter of 0.15 mm is most suitable solenoid is used as a temperature sensor cold. This sensor has a degree of linearity better and more sensitive than other sensors. Equation-temperature circuit followed by I is the current and T the temperature of the medium.<strong></strong></p>http://journal.lppmunindra.ac.id/index.php/Faktor_Exacta/article/view/787
collection DOAJ
language Indonesian
format Article
sources DOAJ
author HALLEYNA WIDYASARI
MOH. TOIFUR
spellingShingle HALLEYNA WIDYASARI
MOH. TOIFUR
OPTIMALISASI DIAMETER KAWAT UNTUK KOMPONEN SENSOR SUHU RENDAH BERBASIS SUSEPTIBILITAS
Faktor Exacta
author_facet HALLEYNA WIDYASARI
MOH. TOIFUR
author_sort HALLEYNA WIDYASARI
title OPTIMALISASI DIAMETER KAWAT UNTUK KOMPONEN SENSOR SUHU RENDAH BERBASIS SUSEPTIBILITAS
title_short OPTIMALISASI DIAMETER KAWAT UNTUK KOMPONEN SENSOR SUHU RENDAH BERBASIS SUSEPTIBILITAS
title_full OPTIMALISASI DIAMETER KAWAT UNTUK KOMPONEN SENSOR SUHU RENDAH BERBASIS SUSEPTIBILITAS
title_fullStr OPTIMALISASI DIAMETER KAWAT UNTUK KOMPONEN SENSOR SUHU RENDAH BERBASIS SUSEPTIBILITAS
title_full_unstemmed OPTIMALISASI DIAMETER KAWAT UNTUK KOMPONEN SENSOR SUHU RENDAH BERBASIS SUSEPTIBILITAS
title_sort optimalisasi diameter kawat untuk komponen sensor suhu rendah berbasis suseptibilitas
publisher Lembaga Penelitian Universitas Indraprasta PGRI
series Faktor Exacta
issn 1979-276X
2502-339X
publishDate 2016-09-01
description <p>Research has been carried out low-temperature sensors based magnetic susceptibility. The study was conducted in order to obtain the most appropriate wire diameter to be used as a low temperature sensor. As the sample used three solenoid with a wire diameter of 0.10 mm; 0.15 mm; and 0.20 mm. Experiments performed using the room temperature was varied from 157K until 253K. Data collection was performed on the multimaster current, the magnetic field induced by the gaussmeter, medium temperature with a digital thermocouple. Medium magnetic susceptibility values obtained by linear regression of data electric current and magnetic induction. Based on the analysis of the data it can be concluded solenoid with a wire diameter of 0.15 mm is most suitable solenoid is used as a temperature sensor cold. This sensor has a degree of linearity better and more sensitive than other sensors. Equation-temperature circuit followed by I is the current and T the temperature of the medium.<strong></strong></p>
url http://journal.lppmunindra.ac.id/index.php/Faktor_Exacta/article/view/787
work_keys_str_mv AT halleynawidyasari optimalisasidiameterkawatuntukkomponensensorsuhurendahberbasissuseptibilitas
AT mohtoifur optimalisasidiameterkawatuntukkomponensensorsuhurendahberbasissuseptibilitas
_version_ 1724992311612407808