Experimental Research on Bending Bearing Capability of Grouted Double Mortise-Tenon Joint for Prefabricated Metro Station Structure

The grouted mortise-tenon joint, invented as the connection between the large prefabricated elements, is the most important component in the prefabricated underground structures. This paper conducts analysis of load-carrying capacity performance and failure mode with 1 : 1 prototype test in key work...

Full description

Bibliographic Details
Main Authors: Xiuren Yang, Fang Lin, Meiqun Huang
Format: Article
Language:English
Published: Hindawi Limited 2021-01-01
Series:Advances in Civil Engineering
Online Access:http://dx.doi.org/10.1155/2021/6635409
id doaj-78acf2ef23a04046a95d4ee71612bbab
record_format Article
spelling doaj-78acf2ef23a04046a95d4ee71612bbab2021-03-29T00:08:51ZengHindawi LimitedAdvances in Civil Engineering1687-80942021-01-01202110.1155/2021/6635409Experimental Research on Bending Bearing Capability of Grouted Double Mortise-Tenon Joint for Prefabricated Metro Station StructureXiuren Yang0Fang Lin1Meiqun Huang2Beijing Urban Construction Design and Development Group Co., LtdBeijing Urban Construction Design and Development Group Co., LtdBeijing Urban Construction Design and Development Group Co., LtdThe grouted mortise-tenon joint, invented as the connection between the large prefabricated elements, is the most important component in the prefabricated underground structures. This paper conducts analysis of load-carrying capacity performance and failure mode with 1 : 1 prototype test in key working direction of different double mortise-tenon joint types for the prefabricated metro station. The resistance moment is developed and used to analyze the bending bearing characteristic curve, and the corresponding test results of each stage of the characteristic curve are described in detail. In addition, the bending bearing performance of different types of double-tenon joints under different load conditions is compared. The test results clarify the ultimate failure mode of double-tenon joint and the variable bearing capacity characteristics of the joint with the increase in axial load and explain the bearing performance of each stage. It is also found the auxiliary pretightening device is helpful to delay the appearance of cracks and improve the bearing capacity, especially when it is set on the tension side. The research results have important application value for the joint design of prefabricated metro station structures.http://dx.doi.org/10.1155/2021/6635409
collection DOAJ
language English
format Article
sources DOAJ
author Xiuren Yang
Fang Lin
Meiqun Huang
spellingShingle Xiuren Yang
Fang Lin
Meiqun Huang
Experimental Research on Bending Bearing Capability of Grouted Double Mortise-Tenon Joint for Prefabricated Metro Station Structure
Advances in Civil Engineering
author_facet Xiuren Yang
Fang Lin
Meiqun Huang
author_sort Xiuren Yang
title Experimental Research on Bending Bearing Capability of Grouted Double Mortise-Tenon Joint for Prefabricated Metro Station Structure
title_short Experimental Research on Bending Bearing Capability of Grouted Double Mortise-Tenon Joint for Prefabricated Metro Station Structure
title_full Experimental Research on Bending Bearing Capability of Grouted Double Mortise-Tenon Joint for Prefabricated Metro Station Structure
title_fullStr Experimental Research on Bending Bearing Capability of Grouted Double Mortise-Tenon Joint for Prefabricated Metro Station Structure
title_full_unstemmed Experimental Research on Bending Bearing Capability of Grouted Double Mortise-Tenon Joint for Prefabricated Metro Station Structure
title_sort experimental research on bending bearing capability of grouted double mortise-tenon joint for prefabricated metro station structure
publisher Hindawi Limited
series Advances in Civil Engineering
issn 1687-8094
publishDate 2021-01-01
description The grouted mortise-tenon joint, invented as the connection between the large prefabricated elements, is the most important component in the prefabricated underground structures. This paper conducts analysis of load-carrying capacity performance and failure mode with 1 : 1 prototype test in key working direction of different double mortise-tenon joint types for the prefabricated metro station. The resistance moment is developed and used to analyze the bending bearing characteristic curve, and the corresponding test results of each stage of the characteristic curve are described in detail. In addition, the bending bearing performance of different types of double-tenon joints under different load conditions is compared. The test results clarify the ultimate failure mode of double-tenon joint and the variable bearing capacity characteristics of the joint with the increase in axial load and explain the bearing performance of each stage. It is also found the auxiliary pretightening device is helpful to delay the appearance of cracks and improve the bearing capacity, especially when it is set on the tension side. The research results have important application value for the joint design of prefabricated metro station structures.
url http://dx.doi.org/10.1155/2021/6635409
work_keys_str_mv AT xiurenyang experimentalresearchonbendingbearingcapabilityofgrouteddoublemortisetenonjointforprefabricatedmetrostationstructure
AT fanglin experimentalresearchonbendingbearingcapabilityofgrouteddoublemortisetenonjointforprefabricatedmetrostationstructure
AT meiqunhuang experimentalresearchonbendingbearingcapabilityofgrouteddoublemortisetenonjointforprefabricatedmetrostationstructure
_version_ 1714761234051497984