Is Ahmed valve superior to Baerveldt implant as an aqueous shunt for the treatment of glaucoma?
Resumen INTRODUCCIÓN La derivación acuosa ha surgido como una técnica alternativa a la trabeculectomía, considerada la cirugía de elección en pacientes con glaucoma. Actualmente, se considera que la principal indicación de esta técnica es ante el fracaso de la trabeculectomía o en tipos de glaucom...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Medwave Estudios Limitada
2018-09-01
|
Series: | Medwave |
id |
doaj-788e296e24ef44a8b833a33793a315ba |
---|---|
record_format |
Article |
spelling |
doaj-788e296e24ef44a8b833a33793a315ba2020-11-25T00:13:46ZengMedwave Estudios LimitadaMedwave0717-63842018-09-011805e7238e723810.5867/medwave.2018.05.7238Is Ahmed valve superior to Baerveldt implant as an aqueous shunt for the treatment of glaucoma?Eduardo Pimentel0Jimena Schmidt1Facultad de Medicina, Pontificia Universidad Católica de Chile, Santiago, ChileProyecto Epistemonikos, Santiago, ChileResumen INTRODUCCIÓN La derivación acuosa ha surgido como una técnica alternativa a la trabeculectomía, considerada la cirugía de elección en pacientes con glaucoma. Actualmente, se considera que la principal indicación de esta técnica es ante el fracaso de la trabeculectomía o en tipos de glaucoma que tienen alto riesgo de fracasar. La válvula Ahmed y el implante Baerveldt son las derivaciones acuosas más utilizadas. Sin embargo, no está claro cuáles son las diferencias entre estas dos alternativas. MÉTODOS Para responder esta pregunta utilizamos Epistemonikos, la mayor base de datos de revisiones sistemáticas en salud a nivel mundial, la cual es mantenida mediante búsquedas en múltiples fuentes de información, incluyendo MEDLINE, EMBASE, Cochrane, entre otras. Extrajimos los datos desde las revisiones identificadas, reanalizamos los datos de los estudios primarios, realizamos un metanálisis y preparamos una tabla de resumen de los resultados utilizando el método GRADE. RESULTADOS Y CONCLUSIONES Identificamos cinco revisiones sistemáticas que en conjunto incluyeron 10 estudios primarios, de los cuales dos son ensayos aleatorizados. Concluimos que la válvula Ahmed probablemente logra una menor disminución de la presión intraocular; podría lograr un menor éxito calificado y probablemente necesita más reintervenciones que el implante Baerveldt. Respecto al perfil |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Eduardo Pimentel Jimena Schmidt |
spellingShingle |
Eduardo Pimentel Jimena Schmidt Is Ahmed valve superior to Baerveldt implant as an aqueous shunt for the treatment of glaucoma? Medwave |
author_facet |
Eduardo Pimentel Jimena Schmidt |
author_sort |
Eduardo Pimentel |
title |
Is Ahmed valve superior to Baerveldt implant as an aqueous shunt for the treatment of glaucoma? |
title_short |
Is Ahmed valve superior to Baerveldt implant as an aqueous shunt for the treatment of glaucoma? |
title_full |
Is Ahmed valve superior to Baerveldt implant as an aqueous shunt for the treatment of glaucoma? |
title_fullStr |
Is Ahmed valve superior to Baerveldt implant as an aqueous shunt for the treatment of glaucoma? |
title_full_unstemmed |
Is Ahmed valve superior to Baerveldt implant as an aqueous shunt for the treatment of glaucoma? |
title_sort |
is ahmed valve superior to baerveldt implant as an aqueous shunt for the treatment of glaucoma? |
publisher |
Medwave Estudios Limitada |
series |
Medwave |
issn |
0717-6384 |
publishDate |
2018-09-01 |
description |
Resumen
INTRODUCCIÓN
La derivación acuosa ha surgido como una técnica alternativa a la trabeculectomía, considerada la cirugía de elección en pacientes con glaucoma. Actualmente, se considera que la principal indicación de esta técnica es ante el fracaso de la trabeculectomía o en tipos de glaucoma que tienen alto riesgo de fracasar. La válvula Ahmed y el implante Baerveldt son las derivaciones acuosas más utilizadas. Sin embargo, no está claro cuáles son las diferencias entre estas dos alternativas.
MÉTODOS
Para responder esta pregunta utilizamos Epistemonikos, la mayor base de datos de revisiones sistemáticas en salud a nivel mundial, la cual es mantenida mediante búsquedas en múltiples fuentes de información, incluyendo MEDLINE, EMBASE, Cochrane, entre otras. Extrajimos los datos desde las revisiones identificadas, reanalizamos los datos de los estudios primarios, realizamos un metanálisis y preparamos una tabla de resumen de los resultados utilizando el método GRADE.
RESULTADOS Y CONCLUSIONES
Identificamos cinco revisiones sistemáticas que en conjunto incluyeron 10 estudios primarios, de los cuales dos son ensayos aleatorizados. Concluimos que la válvula Ahmed probablemente logra una menor disminución de la presión intraocular; podría lograr un menor éxito calificado y probablemente necesita más reintervenciones que el implante Baerveldt. Respecto al perfil |
work_keys_str_mv |
AT eduardopimentel isahmedvalvesuperiortobaerveldtimplantasanaqueousshuntforthetreatmentofglaucoma AT jimenaschmidt isahmedvalvesuperiortobaerveldtimplantasanaqueousshuntforthetreatmentofglaucoma |
_version_ |
1725393103801548800 |