Is Ahmed valve superior to Baerveldt implant as an aqueous shunt for the treatment of glaucoma?

Resumen INTRODUCCIÓN La derivación acuosa ha surgido como una técnica alternativa a la trabeculectomía, considerada la cirugía de elección en pacientes con glaucoma. Actualmente, se considera que la principal indicación de esta técnica es ante el fracaso de la trabeculectomía o en tipos de glaucom...

Full description

Bibliographic Details
Main Authors: Eduardo Pimentel, Jimena Schmidt
Format: Article
Language:English
Published: Medwave Estudios Limitada 2018-09-01
Series:Medwave
id doaj-788e296e24ef44a8b833a33793a315ba
record_format Article
spelling doaj-788e296e24ef44a8b833a33793a315ba2020-11-25T00:13:46ZengMedwave Estudios LimitadaMedwave0717-63842018-09-011805e7238e723810.5867/medwave.2018.05.7238Is Ahmed valve superior to Baerveldt implant as an aqueous shunt for the treatment of glaucoma?Eduardo Pimentel0Jimena Schmidt1Facultad de Medicina, Pontificia Universidad Católica de Chile, Santiago, ChileProyecto Epistemonikos, Santiago, ChileResumen INTRODUCCIÓN La derivación acuosa ha surgido como una técnica alternativa a la trabeculectomía, considerada la cirugía de elección en pacientes con glaucoma. Actualmente, se considera que la principal indicación de esta técnica es ante el fracaso de la trabeculectomía o en tipos de glaucoma que tienen alto riesgo de fracasar. La válvula Ahmed y el implante Baerveldt son las derivaciones acuosas más utilizadas. Sin embargo, no está claro cuáles son las diferencias entre estas dos alternativas. MÉTODOS Para responder esta pregunta utilizamos Epistemonikos, la mayor base de datos de revisiones sistemáticas en salud a nivel mundial, la cual es mantenida mediante búsquedas en múltiples fuentes de información, incluyendo MEDLINE, EMBASE, Cochrane, entre otras. Extrajimos los datos desde las revisiones identificadas, reanalizamos los datos de los estudios primarios, realizamos un metanálisis y preparamos una tabla de resumen de los resultados utilizando el método GRADE. RESULTADOS Y CONCLUSIONES Identificamos cinco revisiones sistemáticas que en conjunto incluyeron 10 estudios primarios, de los cuales dos son ensayos aleatorizados. Concluimos que la válvula Ahmed probablemente logra una menor disminución de la presión intraocular; podría lograr un menor éxito calificado y probablemente necesita más reintervenciones que el implante Baerveldt. Respecto al perfil
collection DOAJ
language English
format Article
sources DOAJ
author Eduardo Pimentel
Jimena Schmidt
spellingShingle Eduardo Pimentel
Jimena Schmidt
Is Ahmed valve superior to Baerveldt implant as an aqueous shunt for the treatment of glaucoma?
Medwave
author_facet Eduardo Pimentel
Jimena Schmidt
author_sort Eduardo Pimentel
title Is Ahmed valve superior to Baerveldt implant as an aqueous shunt for the treatment of glaucoma?
title_short Is Ahmed valve superior to Baerveldt implant as an aqueous shunt for the treatment of glaucoma?
title_full Is Ahmed valve superior to Baerveldt implant as an aqueous shunt for the treatment of glaucoma?
title_fullStr Is Ahmed valve superior to Baerveldt implant as an aqueous shunt for the treatment of glaucoma?
title_full_unstemmed Is Ahmed valve superior to Baerveldt implant as an aqueous shunt for the treatment of glaucoma?
title_sort is ahmed valve superior to baerveldt implant as an aqueous shunt for the treatment of glaucoma?
publisher Medwave Estudios Limitada
series Medwave
issn 0717-6384
publishDate 2018-09-01
description Resumen INTRODUCCIÓN La derivación acuosa ha surgido como una técnica alternativa a la trabeculectomía, considerada la cirugía de elección en pacientes con glaucoma. Actualmente, se considera que la principal indicación de esta técnica es ante el fracaso de la trabeculectomía o en tipos de glaucoma que tienen alto riesgo de fracasar. La válvula Ahmed y el implante Baerveldt son las derivaciones acuosas más utilizadas. Sin embargo, no está claro cuáles son las diferencias entre estas dos alternativas. MÉTODOS Para responder esta pregunta utilizamos Epistemonikos, la mayor base de datos de revisiones sistemáticas en salud a nivel mundial, la cual es mantenida mediante búsquedas en múltiples fuentes de información, incluyendo MEDLINE, EMBASE, Cochrane, entre otras. Extrajimos los datos desde las revisiones identificadas, reanalizamos los datos de los estudios primarios, realizamos un metanálisis y preparamos una tabla de resumen de los resultados utilizando el método GRADE. RESULTADOS Y CONCLUSIONES Identificamos cinco revisiones sistemáticas que en conjunto incluyeron 10 estudios primarios, de los cuales dos son ensayos aleatorizados. Concluimos que la válvula Ahmed probablemente logra una menor disminución de la presión intraocular; podría lograr un menor éxito calificado y probablemente necesita más reintervenciones que el implante Baerveldt. Respecto al perfil
work_keys_str_mv AT eduardopimentel isahmedvalvesuperiortobaerveldtimplantasanaqueousshuntforthetreatmentofglaucoma
AT jimenaschmidt isahmedvalvesuperiortobaerveldtimplantasanaqueousshuntforthetreatmentofglaucoma
_version_ 1725393103801548800