Frequency-resolved analysis of coherent oscillations of local cerebral blood volume, measured with near-infrared spectroscopy, and systemic arterial pressure in healthy human subjects.
We report a study on twenty-two healthy human subjects of the dynamic relationship between cerebral hemoglobin concentration ([HbT]), measured with near-infrared spectroscopy (NIRS) in the prefrontal cortex, and systemic arterial blood pressure (ABP), measured with finger plethysmography. [HbT] is a...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Public Library of Science (PLoS)
2019-01-01
|
Series: | PLoS ONE |
Online Access: | https://doi.org/10.1371/journal.pone.0211710 |
id |
doaj-77f47ef906c047c1b6217f79840ced66 |
---|---|
record_format |
Article |
spelling |
doaj-77f47ef906c047c1b6217f79840ced662021-03-03T20:53:27ZengPublic Library of Science (PLoS)PLoS ONE1932-62032019-01-01142e021171010.1371/journal.pone.0211710Frequency-resolved analysis of coherent oscillations of local cerebral blood volume, measured with near-infrared spectroscopy, and systemic arterial pressure in healthy human subjects.Kristen TgavalekosThao PhamNishanth KrishnamurthyAngelo SassaroliSergio FantiniWe report a study on twenty-two healthy human subjects of the dynamic relationship between cerebral hemoglobin concentration ([HbT]), measured with near-infrared spectroscopy (NIRS) in the prefrontal cortex, and systemic arterial blood pressure (ABP), measured with finger plethysmography. [HbT] is a measure of local cerebral blood volume (CBV). We induced hemodynamic oscillations at discrete frequencies in the range 0.04-0.20 Hz with cyclic inflation and deflation of pneumatic cuffs wrapped around the subject's thighs. We modeled the transfer function of ABP and [HbT] in terms of effective arterial (K(a)) and venous (K(v)) compliances, and a cerebral autoregulation time constant (τ(AR)). The mean values (± standard errors) of these parameters across the twenty-two subjects were K(a) = 0.01 ± 0.01 μM/mmHg, K(v) = 0.09 ± 0.05 μM/mmHg, and τ(AR) = 2.2 ± 1.3 s. Spatially resolved measurements in a subset of eight subjects reveal a spatial variability of these parameters that may exceed the inter-subject variability at a set location. This study sheds some light onto the role that ABP and cerebral blood flow (CBF) play in the dynamics of [HbT] measured with NIRS, and paves the way for new non-invasive optical studies of cerebral blood flow and cerebral autoregulation.https://doi.org/10.1371/journal.pone.0211710 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Kristen Tgavalekos Thao Pham Nishanth Krishnamurthy Angelo Sassaroli Sergio Fantini |
spellingShingle |
Kristen Tgavalekos Thao Pham Nishanth Krishnamurthy Angelo Sassaroli Sergio Fantini Frequency-resolved analysis of coherent oscillations of local cerebral blood volume, measured with near-infrared spectroscopy, and systemic arterial pressure in healthy human subjects. PLoS ONE |
author_facet |
Kristen Tgavalekos Thao Pham Nishanth Krishnamurthy Angelo Sassaroli Sergio Fantini |
author_sort |
Kristen Tgavalekos |
title |
Frequency-resolved analysis of coherent oscillations of local cerebral blood volume, measured with near-infrared spectroscopy, and systemic arterial pressure in healthy human subjects. |
title_short |
Frequency-resolved analysis of coherent oscillations of local cerebral blood volume, measured with near-infrared spectroscopy, and systemic arterial pressure in healthy human subjects. |
title_full |
Frequency-resolved analysis of coherent oscillations of local cerebral blood volume, measured with near-infrared spectroscopy, and systemic arterial pressure in healthy human subjects. |
title_fullStr |
Frequency-resolved analysis of coherent oscillations of local cerebral blood volume, measured with near-infrared spectroscopy, and systemic arterial pressure in healthy human subjects. |
title_full_unstemmed |
Frequency-resolved analysis of coherent oscillations of local cerebral blood volume, measured with near-infrared spectroscopy, and systemic arterial pressure in healthy human subjects. |
title_sort |
frequency-resolved analysis of coherent oscillations of local cerebral blood volume, measured with near-infrared spectroscopy, and systemic arterial pressure in healthy human subjects. |
publisher |
Public Library of Science (PLoS) |
series |
PLoS ONE |
issn |
1932-6203 |
publishDate |
2019-01-01 |
description |
We report a study on twenty-two healthy human subjects of the dynamic relationship between cerebral hemoglobin concentration ([HbT]), measured with near-infrared spectroscopy (NIRS) in the prefrontal cortex, and systemic arterial blood pressure (ABP), measured with finger plethysmography. [HbT] is a measure of local cerebral blood volume (CBV). We induced hemodynamic oscillations at discrete frequencies in the range 0.04-0.20 Hz with cyclic inflation and deflation of pneumatic cuffs wrapped around the subject's thighs. We modeled the transfer function of ABP and [HbT] in terms of effective arterial (K(a)) and venous (K(v)) compliances, and a cerebral autoregulation time constant (τ(AR)). The mean values (± standard errors) of these parameters across the twenty-two subjects were K(a) = 0.01 ± 0.01 μM/mmHg, K(v) = 0.09 ± 0.05 μM/mmHg, and τ(AR) = 2.2 ± 1.3 s. Spatially resolved measurements in a subset of eight subjects reveal a spatial variability of these parameters that may exceed the inter-subject variability at a set location. This study sheds some light onto the role that ABP and cerebral blood flow (CBF) play in the dynamics of [HbT] measured with NIRS, and paves the way for new non-invasive optical studies of cerebral blood flow and cerebral autoregulation. |
url |
https://doi.org/10.1371/journal.pone.0211710 |
work_keys_str_mv |
AT kristentgavalekos frequencyresolvedanalysisofcoherentoscillationsoflocalcerebralbloodvolumemeasuredwithnearinfraredspectroscopyandsystemicarterialpressureinhealthyhumansubjects AT thaopham frequencyresolvedanalysisofcoherentoscillationsoflocalcerebralbloodvolumemeasuredwithnearinfraredspectroscopyandsystemicarterialpressureinhealthyhumansubjects AT nishanthkrishnamurthy frequencyresolvedanalysisofcoherentoscillationsoflocalcerebralbloodvolumemeasuredwithnearinfraredspectroscopyandsystemicarterialpressureinhealthyhumansubjects AT angelosassaroli frequencyresolvedanalysisofcoherentoscillationsoflocalcerebralbloodvolumemeasuredwithnearinfraredspectroscopyandsystemicarterialpressureinhealthyhumansubjects AT sergiofantini frequencyresolvedanalysisofcoherentoscillationsoflocalcerebralbloodvolumemeasuredwithnearinfraredspectroscopyandsystemicarterialpressureinhealthyhumansubjects |
_version_ |
1714820019856080896 |