Reliability of measurements of rat lateral gastrocnemius architectural parameters obtained from ultrasound biomicroscopic images.

This study used ultrasound biomicroscopy (UBM) to quantify the pennation angle (PA) and muscle thickness (MT) of rat skeletal muscle and evaluated the reliability and reproducibility of the method by statistical analysis, determining the coefficient of variation (CV), intraclass correlation coeffici...

Full description

Bibliographic Details
Main Authors: Carolina Carneiro Peixinho, Natália Santos da Fonseca Martins, Liliam Fernandes de Oliveira, João Carlos Machado
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2014-01-01
Series:PLoS ONE
Online Access:http://europepmc.org/articles/PMC3914850?pdf=render
id doaj-7799b67ec27443a484d5e933c007af4c
record_format Article
spelling doaj-7799b67ec27443a484d5e933c007af4c2020-11-24T21:45:08ZengPublic Library of Science (PLoS)PLoS ONE1932-62032014-01-0192e8769110.1371/journal.pone.0087691Reliability of measurements of rat lateral gastrocnemius architectural parameters obtained from ultrasound biomicroscopic images.Carolina Carneiro PeixinhoNatália Santos da Fonseca MartinsLiliam Fernandes de OliveiraJoão Carlos MachadoThis study used ultrasound biomicroscopy (UBM) to quantify the pennation angle (PA) and muscle thickness (MT) of rat skeletal muscle and evaluated the reliability and reproducibility of the method by statistical analysis, determining the coefficient of variation (CV), intraclass correlation coefficient (ICC) and typical error of measurement. A UBM system with a center frequency of 40 MHz was used to acquire images of the right lateral gastrocnemius of ten male Wistar rats on two different days and with two ankle positions (90° or 150°). Two independent measurements of the PA and MT were randomly performed in each of three picture frames. The analysis resulted in CVs of 10.47% and 4.81% for the PA and the MT, respectively, for the ankle at 90° and 9.24% and 5.98% for the ankle at 150°. Additionally, the ICC values ranged from 0.75 to 0.92 for the PA and 0.57 to 0.99 for the MT. Statistically significant differences between the ankle positions were observed for the PA (p = 0.00013). The reliability of the PA and MT measurements for the rat right lateral gastrocnemius, determined from the ultrasound biomicroscopy images, was high (>0.90) for the methodology proposed. This finding indicates the potential of ultrasound biomicroscopy for quantitative muscle characterization and the longitudinal examination of tissue adaptation to different conditions of use, disease and rehabilitation.http://europepmc.org/articles/PMC3914850?pdf=render
collection DOAJ
language English
format Article
sources DOAJ
author Carolina Carneiro Peixinho
Natália Santos da Fonseca Martins
Liliam Fernandes de Oliveira
João Carlos Machado
spellingShingle Carolina Carneiro Peixinho
Natália Santos da Fonseca Martins
Liliam Fernandes de Oliveira
João Carlos Machado
Reliability of measurements of rat lateral gastrocnemius architectural parameters obtained from ultrasound biomicroscopic images.
PLoS ONE
author_facet Carolina Carneiro Peixinho
Natália Santos da Fonseca Martins
Liliam Fernandes de Oliveira
João Carlos Machado
author_sort Carolina Carneiro Peixinho
title Reliability of measurements of rat lateral gastrocnemius architectural parameters obtained from ultrasound biomicroscopic images.
title_short Reliability of measurements of rat lateral gastrocnemius architectural parameters obtained from ultrasound biomicroscopic images.
title_full Reliability of measurements of rat lateral gastrocnemius architectural parameters obtained from ultrasound biomicroscopic images.
title_fullStr Reliability of measurements of rat lateral gastrocnemius architectural parameters obtained from ultrasound biomicroscopic images.
title_full_unstemmed Reliability of measurements of rat lateral gastrocnemius architectural parameters obtained from ultrasound biomicroscopic images.
title_sort reliability of measurements of rat lateral gastrocnemius architectural parameters obtained from ultrasound biomicroscopic images.
publisher Public Library of Science (PLoS)
series PLoS ONE
issn 1932-6203
publishDate 2014-01-01
description This study used ultrasound biomicroscopy (UBM) to quantify the pennation angle (PA) and muscle thickness (MT) of rat skeletal muscle and evaluated the reliability and reproducibility of the method by statistical analysis, determining the coefficient of variation (CV), intraclass correlation coefficient (ICC) and typical error of measurement. A UBM system with a center frequency of 40 MHz was used to acquire images of the right lateral gastrocnemius of ten male Wistar rats on two different days and with two ankle positions (90° or 150°). Two independent measurements of the PA and MT were randomly performed in each of three picture frames. The analysis resulted in CVs of 10.47% and 4.81% for the PA and the MT, respectively, for the ankle at 90° and 9.24% and 5.98% for the ankle at 150°. Additionally, the ICC values ranged from 0.75 to 0.92 for the PA and 0.57 to 0.99 for the MT. Statistically significant differences between the ankle positions were observed for the PA (p = 0.00013). The reliability of the PA and MT measurements for the rat right lateral gastrocnemius, determined from the ultrasound biomicroscopy images, was high (>0.90) for the methodology proposed. This finding indicates the potential of ultrasound biomicroscopy for quantitative muscle characterization and the longitudinal examination of tissue adaptation to different conditions of use, disease and rehabilitation.
url http://europepmc.org/articles/PMC3914850?pdf=render
work_keys_str_mv AT carolinacarneiropeixinho reliabilityofmeasurementsofratlateralgastrocnemiusarchitecturalparametersobtainedfromultrasoundbiomicroscopicimages
AT nataliasantosdafonsecamartins reliabilityofmeasurementsofratlateralgastrocnemiusarchitecturalparametersobtainedfromultrasoundbiomicroscopicimages
AT liliamfernandesdeoliveira reliabilityofmeasurementsofratlateralgastrocnemiusarchitecturalparametersobtainedfromultrasoundbiomicroscopicimages
AT joaocarlosmachado reliabilityofmeasurementsofratlateralgastrocnemiusarchitecturalparametersobtainedfromultrasoundbiomicroscopicimages
_version_ 1725906399644352512