Assessment of cardiac diastolic function in infants of diabetic mothers using tissue Doppler echocardiography

Abstract Background Limited number of studies evaluated cardiac diastolic function in infants of diabetic mothers using tissue Doppler imaging. The aim of this study was to evaluate diastolic parameters in full-term infants of diabetic mothers compared to healthy full-term neonates using both conven...

Full description

Bibliographic Details
Main Authors: Alaa A. Sobeih, Magdy M. A. Sakr, Rehab K. Abolmaaty
Format: Article
Language:English
Published: SpringerOpen 2020-04-01
Series:Egyptian Pediatric Association Gazette
Subjects:
Online Access:http://link.springer.com/article/10.1186/s43054-020-00021-3
id doaj-779475e39aa64d63bf18479ecbcbcc07
record_format Article
spelling doaj-779475e39aa64d63bf18479ecbcbcc072020-11-25T02:10:47ZengSpringerOpenEgyptian Pediatric Association Gazette2090-99422020-04-016811810.1186/s43054-020-00021-3Assessment of cardiac diastolic function in infants of diabetic mothers using tissue Doppler echocardiographyAlaa A. Sobeih0Magdy M. A. Sakr1Rehab K. Abolmaaty2Pediatric Cardiology Unit, Department of Pediatrics, Faculty of Medicine, Cairo UniversityDepartment of Pediatrics, Faculty of Medicine, Al-Azhar University (Damietta)Neonatal Intensive Care Unit, El-Nasr HospitalAbstract Background Limited number of studies evaluated cardiac diastolic function in infants of diabetic mothers using tissue Doppler imaging. The aim of this study was to evaluate diastolic parameters in full-term infants of diabetic mothers compared to healthy full-term neonates using both conventional echocardiography and tissue Doppler imaging. This study is a comparative study. Fifty consecutive infants of diabetic mothers (cases) in the first 3 days of life: 25 neonates with poor maternal glycemic control (Hemoglobin A1c > 7.5 g/dl) and 25 neonates with good maternal glycemic control (Hemoglobin A1c ≤ 7.5 g/dl). Thirty healthy full-term infants of non-diabetic mothers with age and sex matching were included as controls. The studied groups were assessed by conventional pulsed wave Doppler and tissue Doppler imaging. Results Among pulsed wave Doppler parameters, cases had lower values than controls as regards mitral E velocity, mitral E/A ratio, tricuspid E velocity, and tricuspid E/A ratio, while neonates with poor maternal glycemic control had lower values than those with good maternal glycemic control as regards mitral E/A ratio, tricuspid E velocity, and tricuspid E/A ratio as well as higher mitral A velocity (denoting more diastolic dysfunction). Similarly, among tissue Doppler parameters, cases had lower values than controls as regards septal E' velocity, E'/A' ratio, left ventricular E' velocity, E'/A' ratio, and right ventricular E' velocity as well as higher septal A' velocity, left ventricular A' velocity, and right ventricular A' velocity, while neonates with poor maternal glycemic control had lower values than those with good maternal glycemic control as regards septal E' velocity, E'/A' ratio, left ventricular E' velocity, E'/A' ratio, and right ventricular E' velocity, as well as higher left ventricular A' velocity (denoting more diastolic dysfunction). Tissue Doppler was able to detect higher number of neonates with left ventricular diastolic dysfunction than conventional pulsed wave Doppler. Conclusions Tissue Doppler imaging was found to be able to detect diastolic dysfunction early in infants of diabetic mothers specifically as regards the left ventricle. Tissue Doppler imaging should be considered an integral part of cardiac function assessment in infants of diabetic mothers.http://link.springer.com/article/10.1186/s43054-020-00021-3Diastolic dysfunctionDiastolic functionInfant of diabetic motherMyocardial performance indexTei indexTissue Doppler imaging
collection DOAJ
language English
format Article
sources DOAJ
author Alaa A. Sobeih
Magdy M. A. Sakr
Rehab K. Abolmaaty
spellingShingle Alaa A. Sobeih
Magdy M. A. Sakr
Rehab K. Abolmaaty
Assessment of cardiac diastolic function in infants of diabetic mothers using tissue Doppler echocardiography
Egyptian Pediatric Association Gazette
Diastolic dysfunction
Diastolic function
Infant of diabetic mother
Myocardial performance index
Tei index
Tissue Doppler imaging
author_facet Alaa A. Sobeih
Magdy M. A. Sakr
Rehab K. Abolmaaty
author_sort Alaa A. Sobeih
title Assessment of cardiac diastolic function in infants of diabetic mothers using tissue Doppler echocardiography
title_short Assessment of cardiac diastolic function in infants of diabetic mothers using tissue Doppler echocardiography
title_full Assessment of cardiac diastolic function in infants of diabetic mothers using tissue Doppler echocardiography
title_fullStr Assessment of cardiac diastolic function in infants of diabetic mothers using tissue Doppler echocardiography
title_full_unstemmed Assessment of cardiac diastolic function in infants of diabetic mothers using tissue Doppler echocardiography
title_sort assessment of cardiac diastolic function in infants of diabetic mothers using tissue doppler echocardiography
publisher SpringerOpen
series Egyptian Pediatric Association Gazette
issn 2090-9942
publishDate 2020-04-01
description Abstract Background Limited number of studies evaluated cardiac diastolic function in infants of diabetic mothers using tissue Doppler imaging. The aim of this study was to evaluate diastolic parameters in full-term infants of diabetic mothers compared to healthy full-term neonates using both conventional echocardiography and tissue Doppler imaging. This study is a comparative study. Fifty consecutive infants of diabetic mothers (cases) in the first 3 days of life: 25 neonates with poor maternal glycemic control (Hemoglobin A1c > 7.5 g/dl) and 25 neonates with good maternal glycemic control (Hemoglobin A1c ≤ 7.5 g/dl). Thirty healthy full-term infants of non-diabetic mothers with age and sex matching were included as controls. The studied groups were assessed by conventional pulsed wave Doppler and tissue Doppler imaging. Results Among pulsed wave Doppler parameters, cases had lower values than controls as regards mitral E velocity, mitral E/A ratio, tricuspid E velocity, and tricuspid E/A ratio, while neonates with poor maternal glycemic control had lower values than those with good maternal glycemic control as regards mitral E/A ratio, tricuspid E velocity, and tricuspid E/A ratio as well as higher mitral A velocity (denoting more diastolic dysfunction). Similarly, among tissue Doppler parameters, cases had lower values than controls as regards septal E' velocity, E'/A' ratio, left ventricular E' velocity, E'/A' ratio, and right ventricular E' velocity as well as higher septal A' velocity, left ventricular A' velocity, and right ventricular A' velocity, while neonates with poor maternal glycemic control had lower values than those with good maternal glycemic control as regards septal E' velocity, E'/A' ratio, left ventricular E' velocity, E'/A' ratio, and right ventricular E' velocity, as well as higher left ventricular A' velocity (denoting more diastolic dysfunction). Tissue Doppler was able to detect higher number of neonates with left ventricular diastolic dysfunction than conventional pulsed wave Doppler. Conclusions Tissue Doppler imaging was found to be able to detect diastolic dysfunction early in infants of diabetic mothers specifically as regards the left ventricle. Tissue Doppler imaging should be considered an integral part of cardiac function assessment in infants of diabetic mothers.
topic Diastolic dysfunction
Diastolic function
Infant of diabetic mother
Myocardial performance index
Tei index
Tissue Doppler imaging
url http://link.springer.com/article/10.1186/s43054-020-00021-3
work_keys_str_mv AT alaaasobeih assessmentofcardiacdiastolicfunctionininfantsofdiabeticmothersusingtissuedopplerechocardiography
AT magdymasakr assessmentofcardiacdiastolicfunctionininfantsofdiabeticmothersusingtissuedopplerechocardiography
AT rehabkabolmaaty assessmentofcardiacdiastolicfunctionininfantsofdiabeticmothersusingtissuedopplerechocardiography
_version_ 1724917491740704768