Consideration Factors in Application of Thermocouple Sensors for RCS Temperature Instrumentation

Because of harsh radiated environmental conditions, it is necessary to use thermocouples (TCs) in the temperature instrumentation channels of a reactor coolant system (RCS) in an integrated pressurized water reactor vessel. Conventionally, resistance temperature detectors (RTDs) have been adopted fo...

Full description

Bibliographic Details
Main Authors: Hwang Inkoo, Cheon Sewoo, Park Wonman
Format: Article
Language:English
Published: EDP Sciences 2020-01-01
Series:EPJ Web of Conferences
Subjects:
Online Access:https://www.epj-conferences.org/articles/epjconf/pdf/2020/01/epjconf_animma2019_03005.pdf
id doaj-776f0ead66ba4bacaa9a848414d7f1d6
record_format Article
spelling doaj-776f0ead66ba4bacaa9a848414d7f1d62021-08-02T16:03:53ZengEDP SciencesEPJ Web of Conferences2100-014X2020-01-012250300510.1051/epjconf/202022503005epjconf_animma2019_03005Consideration Factors in Application of Thermocouple Sensors for RCS Temperature InstrumentationHwang InkooCheon SewooPark WonmanBecause of harsh radiated environmental conditions, it is necessary to use thermocouples (TCs) in the temperature instrumentation channels of a reactor coolant system (RCS) in an integrated pressurized water reactor vessel. Conventionally, resistance temperature detectors (RTDs) have been adopted for RCS temperature measurement. Therefore, we have conducted an analysis and review of instrumentation error factors in the measurement circuits of RTD and TC sensors to specify the influence on measurement accuracy for application of TCs instead of RTDs for RCS temperature instrumentation. From the review and analysis results, it is anticipated that a measurement accuracy deterioration would be an issue and that a drift range should be investigated for the anticipated operational temperature conditions.https://www.epj-conferences.org/articles/epjconf/pdf/2020/01/epjconf_animma2019_03005.pdfrtd measurement circuitstc accuracy
collection DOAJ
language English
format Article
sources DOAJ
author Hwang Inkoo
Cheon Sewoo
Park Wonman
spellingShingle Hwang Inkoo
Cheon Sewoo
Park Wonman
Consideration Factors in Application of Thermocouple Sensors for RCS Temperature Instrumentation
EPJ Web of Conferences
rtd measurement circuits
tc accuracy
author_facet Hwang Inkoo
Cheon Sewoo
Park Wonman
author_sort Hwang Inkoo
title Consideration Factors in Application of Thermocouple Sensors for RCS Temperature Instrumentation
title_short Consideration Factors in Application of Thermocouple Sensors for RCS Temperature Instrumentation
title_full Consideration Factors in Application of Thermocouple Sensors for RCS Temperature Instrumentation
title_fullStr Consideration Factors in Application of Thermocouple Sensors for RCS Temperature Instrumentation
title_full_unstemmed Consideration Factors in Application of Thermocouple Sensors for RCS Temperature Instrumentation
title_sort consideration factors in application of thermocouple sensors for rcs temperature instrumentation
publisher EDP Sciences
series EPJ Web of Conferences
issn 2100-014X
publishDate 2020-01-01
description Because of harsh radiated environmental conditions, it is necessary to use thermocouples (TCs) in the temperature instrumentation channels of a reactor coolant system (RCS) in an integrated pressurized water reactor vessel. Conventionally, resistance temperature detectors (RTDs) have been adopted for RCS temperature measurement. Therefore, we have conducted an analysis and review of instrumentation error factors in the measurement circuits of RTD and TC sensors to specify the influence on measurement accuracy for application of TCs instead of RTDs for RCS temperature instrumentation. From the review and analysis results, it is anticipated that a measurement accuracy deterioration would be an issue and that a drift range should be investigated for the anticipated operational temperature conditions.
topic rtd measurement circuits
tc accuracy
url https://www.epj-conferences.org/articles/epjconf/pdf/2020/01/epjconf_animma2019_03005.pdf
work_keys_str_mv AT hwanginkoo considerationfactorsinapplicationofthermocouplesensorsforrcstemperatureinstrumentation
AT cheonsewoo considerationfactorsinapplicationofthermocouplesensorsforrcstemperatureinstrumentation
AT parkwonman considerationfactorsinapplicationofthermocouplesensorsforrcstemperatureinstrumentation
_version_ 1721230130655789056