Consideration Factors in Application of Thermocouple Sensors for RCS Temperature Instrumentation
Because of harsh radiated environmental conditions, it is necessary to use thermocouples (TCs) in the temperature instrumentation channels of a reactor coolant system (RCS) in an integrated pressurized water reactor vessel. Conventionally, resistance temperature detectors (RTDs) have been adopted fo...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
EDP Sciences
2020-01-01
|
Series: | EPJ Web of Conferences |
Subjects: | |
Online Access: | https://www.epj-conferences.org/articles/epjconf/pdf/2020/01/epjconf_animma2019_03005.pdf |
id |
doaj-776f0ead66ba4bacaa9a848414d7f1d6 |
---|---|
record_format |
Article |
spelling |
doaj-776f0ead66ba4bacaa9a848414d7f1d62021-08-02T16:03:53ZengEDP SciencesEPJ Web of Conferences2100-014X2020-01-012250300510.1051/epjconf/202022503005epjconf_animma2019_03005Consideration Factors in Application of Thermocouple Sensors for RCS Temperature InstrumentationHwang InkooCheon SewooPark WonmanBecause of harsh radiated environmental conditions, it is necessary to use thermocouples (TCs) in the temperature instrumentation channels of a reactor coolant system (RCS) in an integrated pressurized water reactor vessel. Conventionally, resistance temperature detectors (RTDs) have been adopted for RCS temperature measurement. Therefore, we have conducted an analysis and review of instrumentation error factors in the measurement circuits of RTD and TC sensors to specify the influence on measurement accuracy for application of TCs instead of RTDs for RCS temperature instrumentation. From the review and analysis results, it is anticipated that a measurement accuracy deterioration would be an issue and that a drift range should be investigated for the anticipated operational temperature conditions.https://www.epj-conferences.org/articles/epjconf/pdf/2020/01/epjconf_animma2019_03005.pdfrtd measurement circuitstc accuracy |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Hwang Inkoo Cheon Sewoo Park Wonman |
spellingShingle |
Hwang Inkoo Cheon Sewoo Park Wonman Consideration Factors in Application of Thermocouple Sensors for RCS Temperature Instrumentation EPJ Web of Conferences rtd measurement circuits tc accuracy |
author_facet |
Hwang Inkoo Cheon Sewoo Park Wonman |
author_sort |
Hwang Inkoo |
title |
Consideration Factors in Application of Thermocouple Sensors for RCS Temperature Instrumentation |
title_short |
Consideration Factors in Application of Thermocouple Sensors for RCS Temperature Instrumentation |
title_full |
Consideration Factors in Application of Thermocouple Sensors for RCS Temperature Instrumentation |
title_fullStr |
Consideration Factors in Application of Thermocouple Sensors for RCS Temperature Instrumentation |
title_full_unstemmed |
Consideration Factors in Application of Thermocouple Sensors for RCS Temperature Instrumentation |
title_sort |
consideration factors in application of thermocouple sensors for rcs temperature instrumentation |
publisher |
EDP Sciences |
series |
EPJ Web of Conferences |
issn |
2100-014X |
publishDate |
2020-01-01 |
description |
Because of harsh radiated environmental conditions, it is necessary to use thermocouples (TCs) in the temperature instrumentation channels of a reactor coolant system (RCS) in an integrated pressurized water reactor vessel. Conventionally, resistance temperature detectors (RTDs) have been adopted for RCS temperature measurement.
Therefore, we have conducted an analysis and review of instrumentation error factors in the measurement circuits of RTD and TC sensors to specify the influence on measurement accuracy for application of TCs instead of RTDs for RCS temperature instrumentation.
From the review and analysis results, it is anticipated that a measurement accuracy deterioration would be an issue and that a drift range should be investigated for the anticipated operational temperature conditions. |
topic |
rtd measurement circuits tc accuracy |
url |
https://www.epj-conferences.org/articles/epjconf/pdf/2020/01/epjconf_animma2019_03005.pdf |
work_keys_str_mv |
AT hwanginkoo considerationfactorsinapplicationofthermocouplesensorsforrcstemperatureinstrumentation AT cheonsewoo considerationfactorsinapplicationofthermocouplesensorsforrcstemperatureinstrumentation AT parkwonman considerationfactorsinapplicationofthermocouplesensorsforrcstemperatureinstrumentation |