Optimalisasi Citra Rekonstruksi Multiplanar Pada Ct Wrist Joint Dengan Perubahan Slice Thickness Dan Reconstruction Interval
The purpose of this study was to determain the value of slice thickness and reconstruction interval in which are able to produce an optimal image.Type of research is an experimental research with observational approach. Data retrieval is done by scanning with Scan 64 Slice MSCT in the wrist joint. V...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | Indonesian |
Published: |
UPPM, Poltekkes Kemenkes Semarang
2015-08-01
|
Series: | Jurnal Riset Kesehatan |
Subjects: | |
Online Access: | http://ejournal.poltekkes-smg.ac.id/ojs/index.php/jrk/article/view/203 |
id |
doaj-7753d6bccb354375aa1a814c8dc857f4 |
---|---|
record_format |
Article |
spelling |
doaj-7753d6bccb354375aa1a814c8dc857f42020-11-25T02:07:09ZindUPPM, Poltekkes Kemenkes SemarangJurnal Riset Kesehatan2252-50682461-10262015-08-012230731110.31983/jrk.v2i2.203175Optimalisasi Citra Rekonstruksi Multiplanar Pada Ct Wrist Joint Dengan Perubahan Slice Thickness Dan Reconstruction IntervalBagus Dwi Handoko0Jeffri Ardiyanto1Panji Wibowo Nurcahyo2Technic of Radiodiagnostic and Radiotherapy Department, Polytechnic Health Ministry of SemarangTechnic of Radiodiagnostic and Radiotherapy Department, Polytechnic Health Ministry of SemarangTechnic of Radiodiagnostic and Radiotherapy Department, Polytechnic Health Ministry of SemarangThe purpose of this study was to determain the value of slice thickness and reconstruction interval in which are able to produce an optimal image.Type of research is an experimental research with observational approach. Data retrieval is done by scanning with Scan 64 Slice MSCT in the wrist joint. Variations combination of slice thickness and interval Reconstruction by 9 (nine) times the variation of slice thickness between 0,5 mm, 1,0 mm, 1,5 mm and Reconstruction interval between 0,5, 1,0, 1,5.The results showed that to obtain optimal visualization of soft tissue and bone on MSCT scan examination Wrist Joint variation of slice thickness 0,5 mm and 1.5 Reconstruction interval can be selected. these variations produce optimal image quality with lower noise,http://ejournal.poltekkes-smg.ac.id/ojs/index.php/jrk/article/view/203MPR, slice thicknessReconstruction intervalCT Wrist Joint |
collection |
DOAJ |
language |
Indonesian |
format |
Article |
sources |
DOAJ |
author |
Bagus Dwi Handoko Jeffri Ardiyanto Panji Wibowo Nurcahyo |
spellingShingle |
Bagus Dwi Handoko Jeffri Ardiyanto Panji Wibowo Nurcahyo Optimalisasi Citra Rekonstruksi Multiplanar Pada Ct Wrist Joint Dengan Perubahan Slice Thickness Dan Reconstruction Interval Jurnal Riset Kesehatan MPR, slice thickness Reconstruction interval CT Wrist Joint |
author_facet |
Bagus Dwi Handoko Jeffri Ardiyanto Panji Wibowo Nurcahyo |
author_sort |
Bagus Dwi Handoko |
title |
Optimalisasi Citra Rekonstruksi Multiplanar Pada Ct Wrist Joint Dengan Perubahan Slice Thickness Dan Reconstruction Interval |
title_short |
Optimalisasi Citra Rekonstruksi Multiplanar Pada Ct Wrist Joint Dengan Perubahan Slice Thickness Dan Reconstruction Interval |
title_full |
Optimalisasi Citra Rekonstruksi Multiplanar Pada Ct Wrist Joint Dengan Perubahan Slice Thickness Dan Reconstruction Interval |
title_fullStr |
Optimalisasi Citra Rekonstruksi Multiplanar Pada Ct Wrist Joint Dengan Perubahan Slice Thickness Dan Reconstruction Interval |
title_full_unstemmed |
Optimalisasi Citra Rekonstruksi Multiplanar Pada Ct Wrist Joint Dengan Perubahan Slice Thickness Dan Reconstruction Interval |
title_sort |
optimalisasi citra rekonstruksi multiplanar pada ct wrist joint dengan perubahan slice thickness dan reconstruction interval |
publisher |
UPPM, Poltekkes Kemenkes Semarang |
series |
Jurnal Riset Kesehatan |
issn |
2252-5068 2461-1026 |
publishDate |
2015-08-01 |
description |
The purpose of this study was to determain the value of slice thickness and reconstruction interval in which are able to produce an optimal image.Type of research is an experimental research with observational approach. Data retrieval is done by scanning with Scan 64 Slice MSCT in the wrist joint. Variations combination of slice thickness and interval Reconstruction by 9 (nine) times the variation of slice thickness between 0,5 mm, 1,0 mm, 1,5 mm and Reconstruction interval between 0,5, 1,0, 1,5.The results showed that to obtain optimal visualization of soft tissue and bone on MSCT scan examination Wrist Joint variation of slice thickness 0,5 mm and 1.5 Reconstruction interval can be selected. these variations produce optimal image quality with lower noise, |
topic |
MPR, slice thickness Reconstruction interval CT Wrist Joint |
url |
http://ejournal.poltekkes-smg.ac.id/ojs/index.php/jrk/article/view/203 |
work_keys_str_mv |
AT bagusdwihandoko optimalisasicitrarekonstruksimultiplanarpadactwristjointdenganperubahanslicethicknessdanreconstructioninterval AT jeffriardiyanto optimalisasicitrarekonstruksimultiplanarpadactwristjointdenganperubahanslicethicknessdanreconstructioninterval AT panjiwibowonurcahyo optimalisasicitrarekonstruksimultiplanarpadactwristjointdenganperubahanslicethicknessdanreconstructioninterval |
_version_ |
1724930873500893184 |