Boussignac CPAP system for brain death confirmation with apneic test in case of acute lung injury/adult respiratory distress syndrome – series of cases

Andrzej Wieczorek,1 Tomasz Gaszynski2 1Department of Anesthesia and Intensive Care, Medical University of Lodz, Lodz, Poland; 2Department of Emergency Medicine and Disaster Medicine, Medical University of Lodz, Lodz, Poland Introduction: There are some patients with severe respiratory disturbances...

Full description

Bibliographic Details
Main Authors: Wieczorek A, Gaszynski T
Format: Article
Language:English
Published: Dove Medical Press 2015-06-01
Series:Therapeutics and Clinical Risk Management
Online Access:http://www.dovepress.com/boussignac-cpap-system-for-brain-death-confirmation-with-apneic-test-i-peer-reviewed-article-TCRM
id doaj-76f8b5665db24dd2ac14060e0d895bb0
record_format Article
spelling doaj-76f8b5665db24dd2ac14060e0d895bb02020-11-25T00:41:52ZengDove Medical PressTherapeutics and Clinical Risk Management1178-203X2015-06-012015default96196522200Boussignac CPAP system for brain death confirmation with apneic test in case of acute lung injury/adult respiratory distress syndrome – series of casesWieczorek AGaszynski TAndrzej Wieczorek,1 Tomasz Gaszynski2 1Department of Anesthesia and Intensive Care, Medical University of Lodz, Lodz, Poland; 2Department of Emergency Medicine and Disaster Medicine, Medical University of Lodz, Lodz, Poland Introduction: There are some patients with severe respiratory disturbances like adult respiratory distress syndrome (ARDS) and suspicion of brain death, for whom typical performance of the apneic test is difficult to complete because of quick desaturation and rapid deterioration without effective ventilation. To avoid failure of brain death confirmation and possible loss of organ donation another approach to apneic test is needed. We present two cases of patients with clinical symptoms of brain death, with lung pathology (acute lung injury, ARDS, lung embolism and lung infection), in whom apneic tests for recognizing brain death were difficult to perform. During typical performance of apneic test involving the use of oxygen catheter for apneic oxygenation we observed severe desaturation with growing hypotension and hemodynamic destabilization. But with the use of Boussignac CPAP system all necessary tests were successfully completed, confirming the patient’s brain death, which gave us the opportunity to perform procedures for organ donation. The main reason of apneic test difficulties was severe gas exchange disturbances secondary to ARDS. Thus lack of positive end expiratory pressure during classical performance of apneic test leads to quick desaturation and rapid hemodynamic deterioration, limiting the observation period below dedicated at least 10-minute interval.  Conclusion: The Boussignac CPAP system may be an effective tool for performing transparent apneic test in case of serious respiratory disturbances, especially in the form of acute lung injury or ARDS. Keywords: brain death, organ donor, ARDS, ALI, Boussignac CPAPhttp://www.dovepress.com/boussignac-cpap-system-for-brain-death-confirmation-with-apneic-test-i-peer-reviewed-article-TCRM
collection DOAJ
language English
format Article
sources DOAJ
author Wieczorek A
Gaszynski T
spellingShingle Wieczorek A
Gaszynski T
Boussignac CPAP system for brain death confirmation with apneic test in case of acute lung injury/adult respiratory distress syndrome – series of cases
Therapeutics and Clinical Risk Management
author_facet Wieczorek A
Gaszynski T
author_sort Wieczorek A
title Boussignac CPAP system for brain death confirmation with apneic test in case of acute lung injury/adult respiratory distress syndrome – series of cases
title_short Boussignac CPAP system for brain death confirmation with apneic test in case of acute lung injury/adult respiratory distress syndrome – series of cases
title_full Boussignac CPAP system for brain death confirmation with apneic test in case of acute lung injury/adult respiratory distress syndrome – series of cases
title_fullStr Boussignac CPAP system for brain death confirmation with apneic test in case of acute lung injury/adult respiratory distress syndrome – series of cases
title_full_unstemmed Boussignac CPAP system for brain death confirmation with apneic test in case of acute lung injury/adult respiratory distress syndrome – series of cases
title_sort boussignac cpap system for brain death confirmation with apneic test in case of acute lung injury/adult respiratory distress syndrome – series of cases
publisher Dove Medical Press
series Therapeutics and Clinical Risk Management
issn 1178-203X
publishDate 2015-06-01
description Andrzej Wieczorek,1 Tomasz Gaszynski2 1Department of Anesthesia and Intensive Care, Medical University of Lodz, Lodz, Poland; 2Department of Emergency Medicine and Disaster Medicine, Medical University of Lodz, Lodz, Poland Introduction: There are some patients with severe respiratory disturbances like adult respiratory distress syndrome (ARDS) and suspicion of brain death, for whom typical performance of the apneic test is difficult to complete because of quick desaturation and rapid deterioration without effective ventilation. To avoid failure of brain death confirmation and possible loss of organ donation another approach to apneic test is needed. We present two cases of patients with clinical symptoms of brain death, with lung pathology (acute lung injury, ARDS, lung embolism and lung infection), in whom apneic tests for recognizing brain death were difficult to perform. During typical performance of apneic test involving the use of oxygen catheter for apneic oxygenation we observed severe desaturation with growing hypotension and hemodynamic destabilization. But with the use of Boussignac CPAP system all necessary tests were successfully completed, confirming the patient’s brain death, which gave us the opportunity to perform procedures for organ donation. The main reason of apneic test difficulties was severe gas exchange disturbances secondary to ARDS. Thus lack of positive end expiratory pressure during classical performance of apneic test leads to quick desaturation and rapid hemodynamic deterioration, limiting the observation period below dedicated at least 10-minute interval.  Conclusion: The Boussignac CPAP system may be an effective tool for performing transparent apneic test in case of serious respiratory disturbances, especially in the form of acute lung injury or ARDS. Keywords: brain death, organ donor, ARDS, ALI, Boussignac CPAP
url http://www.dovepress.com/boussignac-cpap-system-for-brain-death-confirmation-with-apneic-test-i-peer-reviewed-article-TCRM
work_keys_str_mv AT wieczoreka boussignaccpapsystemforbraindeathconfirmationwithapneictestincaseofacutelunginjuryadultrespiratorydistresssyndromenbspndashnbspseriesofcases
AT gaszynskit boussignaccpapsystemforbraindeathconfirmationwithapneictestincaseofacutelunginjuryadultrespiratorydistresssyndromenbspndashnbspseriesofcases
_version_ 1716128120246894592