Evaluation of the Correlation between Intracranial Pressures Measured by Schiotz Tonometer and Computed Tomography Scan Findings in Craniotomy Patients before Dura Opening
Background: We evaluated the correlation between intracranial pressure (ICP) measured by Schiotz tonometer and computed tomography (CT) scan findings in craniotomy patients. Methods: This cross-sectional study was performed in Alzahra Hospital in Isfahan from 2010 to 2011. We included the elective...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | fas |
Published: |
Vesnu Publications
2012-12-01
|
Series: | مجله دانشکده پزشکی اصفهان |
Online Access: | http://jims.mui.ac.ir/index.php/jims/article/view/2009 |
id |
doaj-769e25c66d3f40d7a559b7d0e662890f |
---|---|
record_format |
Article |
spelling |
doaj-769e25c66d3f40d7a559b7d0e662890f2020-11-25T01:09:10ZfasVesnu Publications مجله دانشکده پزشکی اصفهان1027-75951735-854X2012-12-0130212181318171190Evaluation of the Correlation between Intracranial Pressures Measured by Schiotz Tonometer and Computed Tomography Scan Findings in Craniotomy Patients before Dura OpeningMehrdad Masoudifar0Reyhanak Talakoub1Payam Ebrahimifar2Assistant Professor, Department of Anesthesiology, School of Medicine, Isfahan University of Medical Sciences, Isfahan, IranAssociate Professor, Department of Anesthesiology, School of Medicine, Isfahan University of Medical Sciences, Isfahan, IranStudent of Medicine, School of Medicine AND Student Research Committee, Isfahan University of Medical Sciences, Isfahan, IranBackground: We evaluated the correlation between intracranial pressure (ICP) measured by Schiotz tonometer and computed tomography (CT) scan findings in craniotomy patients. Methods: This cross-sectional study was performed in Alzahra Hospital in Isfahan from 2010 to 2011. We included the elective craniotomy patients aged 18-64 years with the American Society of Anesthesiologists (ASA) physical status I or II. After being evaluated by CT scan, ICP was studied with Schiotz tonometer in Burr hole before dura opening. Findings: 58 patients (mean age: 44.37 ± 11.53 years) scheduled for elective craniotomy were included in the study. There were 36 males (62.1%) and 22 females (37.9%). The results showed significant correlation between ICP measured by Schiotz tonometer and by CT scan (r = 0.913, P < 0.001). Conclusion: This study showed that Schiotz tonometer could consider as a safe and reliable alternative to CT scan in ICP evaluation. Keywords: Intracranial pressure, Schiotz tonometer, X-ray computed tomographyhttp://jims.mui.ac.ir/index.php/jims/article/view/2009 |
collection |
DOAJ |
language |
fas |
format |
Article |
sources |
DOAJ |
author |
Mehrdad Masoudifar Reyhanak Talakoub Payam Ebrahimifar |
spellingShingle |
Mehrdad Masoudifar Reyhanak Talakoub Payam Ebrahimifar Evaluation of the Correlation between Intracranial Pressures Measured by Schiotz Tonometer and Computed Tomography Scan Findings in Craniotomy Patients before Dura Opening مجله دانشکده پزشکی اصفهان |
author_facet |
Mehrdad Masoudifar Reyhanak Talakoub Payam Ebrahimifar |
author_sort |
Mehrdad Masoudifar |
title |
Evaluation of the Correlation between Intracranial Pressures Measured by Schiotz Tonometer and Computed Tomography Scan Findings in Craniotomy Patients before Dura Opening |
title_short |
Evaluation of the Correlation between Intracranial Pressures Measured by Schiotz Tonometer and Computed Tomography Scan Findings in Craniotomy Patients before Dura Opening |
title_full |
Evaluation of the Correlation between Intracranial Pressures Measured by Schiotz Tonometer and Computed Tomography Scan Findings in Craniotomy Patients before Dura Opening |
title_fullStr |
Evaluation of the Correlation between Intracranial Pressures Measured by Schiotz Tonometer and Computed Tomography Scan Findings in Craniotomy Patients before Dura Opening |
title_full_unstemmed |
Evaluation of the Correlation between Intracranial Pressures Measured by Schiotz Tonometer and Computed Tomography Scan Findings in Craniotomy Patients before Dura Opening |
title_sort |
evaluation of the correlation between intracranial pressures measured by schiotz tonometer and computed tomography scan findings in craniotomy patients before dura opening |
publisher |
Vesnu Publications |
series |
مجله دانشکده پزشکی اصفهان |
issn |
1027-7595 1735-854X |
publishDate |
2012-12-01 |
description |
Background: We evaluated the correlation between intracranial pressure (ICP) measured by Schiotz tonometer and computed tomography (CT) scan findings in craniotomy patients.
Methods: This cross-sectional study was performed in Alzahra Hospital in Isfahan from 2010 to 2011. We included the elective craniotomy patients aged 18-64 years with the American Society of Anesthesiologists (ASA) physical status I or II. After being evaluated by CT scan, ICP was studied with Schiotz tonometer in Burr hole before dura opening.
Findings: 58 patients (mean age: 44.37 ± 11.53 years) scheduled for elective craniotomy were included in the study. There were 36 males (62.1%) and 22 females (37.9%). The results showed significant correlation between ICP measured by Schiotz tonometer and by CT scan (r = 0.913, P < 0.001).
Conclusion: This study showed that Schiotz tonometer could consider as a safe and reliable alternative to CT scan in ICP evaluation.
Keywords: Intracranial pressure, Schiotz tonometer, X-ray computed tomography |
url |
http://jims.mui.ac.ir/index.php/jims/article/view/2009 |
work_keys_str_mv |
AT mehrdadmasoudifar evaluationofthecorrelationbetweenintracranialpressuresmeasuredbyschiotztonometerandcomputedtomographyscanfindingsincraniotomypatientsbeforeduraopening AT reyhanaktalakoub evaluationofthecorrelationbetweenintracranialpressuresmeasuredbyschiotztonometerandcomputedtomographyscanfindingsincraniotomypatientsbeforeduraopening AT payamebrahimifar evaluationofthecorrelationbetweenintracranialpressuresmeasuredbyschiotztonometerandcomputedtomographyscanfindingsincraniotomypatientsbeforeduraopening |
_version_ |
1725179631793864704 |