Investigation of Coliform Removal from Drinking Water by Electrolysis

Introduction & Objective: The practice of eliminating pathogenic microorganisms in water dates back to ancient times. The most common methods for water disinfection are using chemicals, Ozonation, Ultra Violet ray, Membrane Processes and etc. There has been considerable interest in disinfection...

Full description

Bibliographic Details
Main Authors: Alireza Rahmani, Mohammadreza Samarghandi
Format: Article
Language:fas
Published: Hamadan University of Medical Sciences 2008-09-01
Series:پزشکی بالینی ابن سینا
Subjects:
Online Access:http://sjh.umsha.ac.ir/article-1-373-en.html
id doaj-7689e71634364b88a7861b9fcfa6c9f0
record_format Article
spelling doaj-7689e71634364b88a7861b9fcfa6c9f02020-11-25T04:10:45ZfasHamadan University of Medical Sciencesپزشکی بالینی ابن سینا2588-722X2588-72382008-09-011526065Investigation of Coliform Removal from Drinking Water by ElectrolysisAlireza Rahmani0Mohammadreza Samarghandi1 Introduction & Objective: The practice of eliminating pathogenic microorganisms in water dates back to ancient times. The most common methods for water disinfection are using chemicals, Ozonation, Ultra Violet ray, Membrane Processes and etc. There has been considerable interest in disinfection of water by using electrochemical methods in recent years. The main purpose of this study is to conduct experimental investigation of water disinfection by using the electrolysis method. Inactivation and killing Coliform in polluted waters was investigated by different voltage, electrodes (Al, St and Cu) and distance between electrodes. Materials & Methods: The polluted water was prepared by adding a colony of coliform growth on EMB in raw water. Experiments were done similarly via the same electrolyzes time, electrodes distance and voltage intensity for all types of combinations of electrodes respectively. Results: The experimental results show that the removal efficiency depends on the voltage and electrodes material. From the experiments carried out at 10 V. and at current intensity of 135 mA, it was found that five-minute period was sufficient for disinfecting water using Stainless Steel electrodes. Conclusion: Due to the results, the electrochemical methods can be proposed as a promising cleaning and purifying method for water disinfection.http://sjh.umsha.ac.ir/article-1-373-en.htmlcoliformdisinfectionelectrolysiswater treatment
collection DOAJ
language fas
format Article
sources DOAJ
author Alireza Rahmani
Mohammadreza Samarghandi
spellingShingle Alireza Rahmani
Mohammadreza Samarghandi
Investigation of Coliform Removal from Drinking Water by Electrolysis
پزشکی بالینی ابن سینا
coliform
disinfection
electrolysis
water treatment
author_facet Alireza Rahmani
Mohammadreza Samarghandi
author_sort Alireza Rahmani
title Investigation of Coliform Removal from Drinking Water by Electrolysis
title_short Investigation of Coliform Removal from Drinking Water by Electrolysis
title_full Investigation of Coliform Removal from Drinking Water by Electrolysis
title_fullStr Investigation of Coliform Removal from Drinking Water by Electrolysis
title_full_unstemmed Investigation of Coliform Removal from Drinking Water by Electrolysis
title_sort investigation of coliform removal from drinking water by electrolysis
publisher Hamadan University of Medical Sciences
series پزشکی بالینی ابن سینا
issn 2588-722X
2588-7238
publishDate 2008-09-01
description Introduction & Objective: The practice of eliminating pathogenic microorganisms in water dates back to ancient times. The most common methods for water disinfection are using chemicals, Ozonation, Ultra Violet ray, Membrane Processes and etc. There has been considerable interest in disinfection of water by using electrochemical methods in recent years. The main purpose of this study is to conduct experimental investigation of water disinfection by using the electrolysis method. Inactivation and killing Coliform in polluted waters was investigated by different voltage, electrodes (Al, St and Cu) and distance between electrodes. Materials & Methods: The polluted water was prepared by adding a colony of coliform growth on EMB in raw water. Experiments were done similarly via the same electrolyzes time, electrodes distance and voltage intensity for all types of combinations of electrodes respectively. Results: The experimental results show that the removal efficiency depends on the voltage and electrodes material. From the experiments carried out at 10 V. and at current intensity of 135 mA, it was found that five-minute period was sufficient for disinfecting water using Stainless Steel electrodes. Conclusion: Due to the results, the electrochemical methods can be proposed as a promising cleaning and purifying method for water disinfection.
topic coliform
disinfection
electrolysis
water treatment
url http://sjh.umsha.ac.ir/article-1-373-en.html
work_keys_str_mv AT alirezarahmani investigationofcoliformremovalfromdrinkingwaterbyelectrolysis
AT mohammadrezasamarghandi investigationofcoliformremovalfromdrinkingwaterbyelectrolysis
_version_ 1724419384696373248