Response in Ambient Low Temperature Plasma Ionization Compared to Electrospray and Atmospheric Pressure Chemical Ionization for Mass Spectrometry

Modern technical evolution made mass spectrometry (MS) an absolute must for analytical chemistry in terms of application range, detection limits and speed. When it comes to mass spectrometric detection, one of the critical steps is to ionize the analyte and bring it into the gas phase. Several ioniz...

Full description

Bibliographic Details
Main Authors: Andreas Kiontke, Susan Billig, Claudia Birkemeyer
Format: Article
Language:English
Published: Hindawi Limited 2018-01-01
Series:International Journal of Analytical Chemistry
Online Access:http://dx.doi.org/10.1155/2018/5647536
id doaj-7611151ba8ce453796e20e5add8825be
record_format Article
spelling doaj-7611151ba8ce453796e20e5add8825be2020-11-25T00:40:02ZengHindawi LimitedInternational Journal of Analytical Chemistry1687-87601687-87792018-01-01201810.1155/2018/56475365647536Response in Ambient Low Temperature Plasma Ionization Compared to Electrospray and Atmospheric Pressure Chemical Ionization for Mass SpectrometryAndreas Kiontke0Susan Billig1Claudia Birkemeyer2Research Group of Mass Spectrometry at the Faculty of Chemistry and Mineralogy, University of Leipzig, Linnéstr. 3, 04103 Leipzig, GermanyResearch Group of Mass Spectrometry at the Faculty of Chemistry and Mineralogy, University of Leipzig, Linnéstr. 3, 04103 Leipzig, GermanyResearch Group of Mass Spectrometry at the Faculty of Chemistry and Mineralogy, University of Leipzig, Linnéstr. 3, 04103 Leipzig, GermanyModern technical evolution made mass spectrometry (MS) an absolute must for analytical chemistry in terms of application range, detection limits and speed. When it comes to mass spectrometric detection, one of the critical steps is to ionize the analyte and bring it into the gas phase. Several ionization techniques were developed for this purpose among which electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) are two of the most frequently applied atmospheric pressure methods to ionize target compounds from liquid matrices or solutions. Moreover, recent efforts in the emerging field of “ambient” MS enable the applicability of newly developed atmospheric pressure techniques to solid matrices, greatly simplifying the analysis of samples with MS and anticipating, to ease the required or even leave out any sample preparation and enable analysis at ambient conditions, outside the instrument itself. These developments greatly extend the range of applications of modern mass spectrometry (MS). Ambient methods comprise many techniques; a particular prominent group is, however, the plasma-based methods. Although ambient MS is a rather new field of research, the interest in further developing the corresponding techniques and enhancing their performance is very strong due to their simplicity and often low cost of manufacturing. A precondition for improving the performance of such ion sources is a profound understanding how ionization works and which parameters determine signal response. Therefore, we review relevant compound characteristics for ionization with the two traditional methods ESI and APCI and compare those with one of the most frequently employed representatives of the plasma-based methods, i.e., low temperature plasma ionization. We present a detailed analysis in which compound characteristics are most beneficial for the response of aromatic nitrogen-containing compounds with these three methods and provide evidence that desorption characteristics appear to have the main common, general impact on signal response. In conclusion, our report provides a very useful resource to the optimization of instrumental conditions with respect to most important requirements of the three ionization techniques and, at the same time, for future developments in the field of ambient ionization.http://dx.doi.org/10.1155/2018/5647536
collection DOAJ
language English
format Article
sources DOAJ
author Andreas Kiontke
Susan Billig
Claudia Birkemeyer
spellingShingle Andreas Kiontke
Susan Billig
Claudia Birkemeyer
Response in Ambient Low Temperature Plasma Ionization Compared to Electrospray and Atmospheric Pressure Chemical Ionization for Mass Spectrometry
International Journal of Analytical Chemistry
author_facet Andreas Kiontke
Susan Billig
Claudia Birkemeyer
author_sort Andreas Kiontke
title Response in Ambient Low Temperature Plasma Ionization Compared to Electrospray and Atmospheric Pressure Chemical Ionization for Mass Spectrometry
title_short Response in Ambient Low Temperature Plasma Ionization Compared to Electrospray and Atmospheric Pressure Chemical Ionization for Mass Spectrometry
title_full Response in Ambient Low Temperature Plasma Ionization Compared to Electrospray and Atmospheric Pressure Chemical Ionization for Mass Spectrometry
title_fullStr Response in Ambient Low Temperature Plasma Ionization Compared to Electrospray and Atmospheric Pressure Chemical Ionization for Mass Spectrometry
title_full_unstemmed Response in Ambient Low Temperature Plasma Ionization Compared to Electrospray and Atmospheric Pressure Chemical Ionization for Mass Spectrometry
title_sort response in ambient low temperature plasma ionization compared to electrospray and atmospheric pressure chemical ionization for mass spectrometry
publisher Hindawi Limited
series International Journal of Analytical Chemistry
issn 1687-8760
1687-8779
publishDate 2018-01-01
description Modern technical evolution made mass spectrometry (MS) an absolute must for analytical chemistry in terms of application range, detection limits and speed. When it comes to mass spectrometric detection, one of the critical steps is to ionize the analyte and bring it into the gas phase. Several ionization techniques were developed for this purpose among which electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) are two of the most frequently applied atmospheric pressure methods to ionize target compounds from liquid matrices or solutions. Moreover, recent efforts in the emerging field of “ambient” MS enable the applicability of newly developed atmospheric pressure techniques to solid matrices, greatly simplifying the analysis of samples with MS and anticipating, to ease the required or even leave out any sample preparation and enable analysis at ambient conditions, outside the instrument itself. These developments greatly extend the range of applications of modern mass spectrometry (MS). Ambient methods comprise many techniques; a particular prominent group is, however, the plasma-based methods. Although ambient MS is a rather new field of research, the interest in further developing the corresponding techniques and enhancing their performance is very strong due to their simplicity and often low cost of manufacturing. A precondition for improving the performance of such ion sources is a profound understanding how ionization works and which parameters determine signal response. Therefore, we review relevant compound characteristics for ionization with the two traditional methods ESI and APCI and compare those with one of the most frequently employed representatives of the plasma-based methods, i.e., low temperature plasma ionization. We present a detailed analysis in which compound characteristics are most beneficial for the response of aromatic nitrogen-containing compounds with these three methods and provide evidence that desorption characteristics appear to have the main common, general impact on signal response. In conclusion, our report provides a very useful resource to the optimization of instrumental conditions with respect to most important requirements of the three ionization techniques and, at the same time, for future developments in the field of ambient ionization.
url http://dx.doi.org/10.1155/2018/5647536
work_keys_str_mv AT andreaskiontke responseinambientlowtemperatureplasmaionizationcomparedtoelectrosprayandatmosphericpressurechemicalionizationformassspectrometry
AT susanbillig responseinambientlowtemperatureplasmaionizationcomparedtoelectrosprayandatmosphericpressurechemicalionizationformassspectrometry
AT claudiabirkemeyer responseinambientlowtemperatureplasmaionizationcomparedtoelectrosprayandatmosphericpressurechemicalionizationformassspectrometry
_version_ 1725291819949883392