Genetically Encoded Voltage Indicators Are Illuminating Subcellular Physiology of the Axon

Everything we see and do is regulated by electrical signals in our nerves and muscle. Ion channels are crucial for sensing and generating electrical signals. Two voltage-dependent conductances, Na+ and K+, form the bedrock of the electrical impulse in the brain known as the action potential. Several...

Full description

Bibliographic Details
Main Authors: Lauren C. Panzera, Michael B. Hoppa
Format: Article
Language:English
Published: Frontiers Media S.A. 2019-03-01
Series:Frontiers in Cellular Neuroscience
Subjects:
Online Access:https://www.frontiersin.org/article/10.3389/fncel.2019.00052/full
id doaj-75ec04ea866c4ea7b653ead215d2eac6
record_format Article
spelling doaj-75ec04ea866c4ea7b653ead215d2eac62020-11-24T23:48:33ZengFrontiers Media S.A.Frontiers in Cellular Neuroscience1662-51022019-03-011310.3389/fncel.2019.00052443630Genetically Encoded Voltage Indicators Are Illuminating Subcellular Physiology of the AxonLauren C. PanzeraMichael B. HoppaEverything we see and do is regulated by electrical signals in our nerves and muscle. Ion channels are crucial for sensing and generating electrical signals. Two voltage-dependent conductances, Na+ and K+, form the bedrock of the electrical impulse in the brain known as the action potential. Several classes of mammalian neurons express combinations of nearly 100 different varieties of these two voltage-dependent channels and their subunits. Not surprisingly, this variability orchestrates a diversity of action potential shapes and firing patterns that have been studied in detail at neural somata. A remarkably understudied phenomena exists in subcellular compartments of the axon, where action potentials initiate synaptic transmission. Ion channel research was catalyzed by the invention of glass electrodes to measure electrical signals in cell membranes, however, progress in the field of neurobiology has been stymied by the fact that most axons in the mammalian CNS are far too small and delicate for measuring ion channel function with electrodes. These quantitative measurements of membrane voltage can be achieved within the axon using light. A revolution of optical voltage sensors has enabled exploring important questions of how ion channels regulate axon physiology and synaptic transmission. In this review we will consider advantages and disadvantages of different fluorescent voltage indicators and discuss particularly relevant questions that these indicators can elucidate for understanding the crucial relationship between action potentials and synaptic transmission.https://www.frontiersin.org/article/10.3389/fncel.2019.00052/fullgenetically encoded voltage indicatorsaxonsynaptic transmissionvoltageaction potentials
collection DOAJ
language English
format Article
sources DOAJ
author Lauren C. Panzera
Michael B. Hoppa
spellingShingle Lauren C. Panzera
Michael B. Hoppa
Genetically Encoded Voltage Indicators Are Illuminating Subcellular Physiology of the Axon
Frontiers in Cellular Neuroscience
genetically encoded voltage indicators
axon
synaptic transmission
voltage
action potentials
author_facet Lauren C. Panzera
Michael B. Hoppa
author_sort Lauren C. Panzera
title Genetically Encoded Voltage Indicators Are Illuminating Subcellular Physiology of the Axon
title_short Genetically Encoded Voltage Indicators Are Illuminating Subcellular Physiology of the Axon
title_full Genetically Encoded Voltage Indicators Are Illuminating Subcellular Physiology of the Axon
title_fullStr Genetically Encoded Voltage Indicators Are Illuminating Subcellular Physiology of the Axon
title_full_unstemmed Genetically Encoded Voltage Indicators Are Illuminating Subcellular Physiology of the Axon
title_sort genetically encoded voltage indicators are illuminating subcellular physiology of the axon
publisher Frontiers Media S.A.
series Frontiers in Cellular Neuroscience
issn 1662-5102
publishDate 2019-03-01
description Everything we see and do is regulated by electrical signals in our nerves and muscle. Ion channels are crucial for sensing and generating electrical signals. Two voltage-dependent conductances, Na+ and K+, form the bedrock of the electrical impulse in the brain known as the action potential. Several classes of mammalian neurons express combinations of nearly 100 different varieties of these two voltage-dependent channels and their subunits. Not surprisingly, this variability orchestrates a diversity of action potential shapes and firing patterns that have been studied in detail at neural somata. A remarkably understudied phenomena exists in subcellular compartments of the axon, where action potentials initiate synaptic transmission. Ion channel research was catalyzed by the invention of glass electrodes to measure electrical signals in cell membranes, however, progress in the field of neurobiology has been stymied by the fact that most axons in the mammalian CNS are far too small and delicate for measuring ion channel function with electrodes. These quantitative measurements of membrane voltage can be achieved within the axon using light. A revolution of optical voltage sensors has enabled exploring important questions of how ion channels regulate axon physiology and synaptic transmission. In this review we will consider advantages and disadvantages of different fluorescent voltage indicators and discuss particularly relevant questions that these indicators can elucidate for understanding the crucial relationship between action potentials and synaptic transmission.
topic genetically encoded voltage indicators
axon
synaptic transmission
voltage
action potentials
url https://www.frontiersin.org/article/10.3389/fncel.2019.00052/full
work_keys_str_mv AT laurencpanzera geneticallyencodedvoltageindicatorsareilluminatingsubcellularphysiologyoftheaxon
AT michaelbhoppa geneticallyencodedvoltageindicatorsareilluminatingsubcellularphysiologyoftheaxon
_version_ 1725485629891936256