Influence of microkeratome parameters on the stromal bed and flap edge quality in laser in situ keratomileusis

Jens Heichel,1 Frank Wilhelm,2 Kathleen S Kunert,3 Rabea Schlueter,4 Ute Stuhltraeger,1 Thomas Hammer5 1Department of Ophthalmology, University Hospital of Martin Luther University Halle/Wittenberg, Halle (Saale), Germany; 2Augen im Zentrum, Greifswald, Germany; 3Department of Ophthalmology, Helios...

Full description

Bibliographic Details
Main Authors: Heichel J, Wilhelm F, Kunert KS, Schlueter R, Stuhltraeger U, Hammer T
Format: Article
Language:English
Published: Dove Medical Press 2013-12-01
Series:Clinical Ophthalmology
Online Access:http://www.dovepress.com/influence-of-microkeratome-parameters-on-the-stromal-bed-and-flap-edge-a15305
id doaj-7546aad27451417cb9b3c70a77ffabb2
record_format Article
spelling doaj-7546aad27451417cb9b3c70a77ffabb22020-11-24T23:30:15ZengDove Medical PressClinical Ophthalmology1177-54832013-12-012014default616915305Influence of microkeratome parameters on the stromal bed and flap edge quality in laser in situ keratomileusisHeichel JWilhelm FKunert KSSchlueter RStuhltraeger UHammer T Jens Heichel,1 Frank Wilhelm,2 Kathleen S Kunert,3 Rabea Schlueter,4 Ute Stuhltraeger,1 Thomas Hammer5 1Department of Ophthalmology, University Hospital of Martin Luther University Halle/Wittenberg, Halle (Saale), Germany; 2Augen im Zentrum, Greifswald, Germany; 3Department of Ophthalmology, Helios Klinikum Erfurt, Erfurt, Germany; 4Institute of Microbiology, Ernst-Moritz-Arndt-University, Greifswald, Germany; 5Augenzentrum Frohe Zukunft, Halle (Saale), Germany Purpose: Femtosecond lasers have become the standard for laser-assisted in situ keratomileusis (LASIK) flap creation, but advanced mechanical microkeratomes are still an alternative, more cost-effective way to create the flap. The SCHWIND Carriazo-Pendular microkeratome is one of the most commonly used microkeratomes. The influence of different cutting parameters (head-advance speeds, cutting heads) on morphology of LASIK cuts was investigated. Setting: Experimental study performed at the University Eye Hospital of the Martin Luther University Halle/Wittenberg, Halle (Saale), Germany. Methods: The Carriazo-Pendular microkeratome was used on freshly enucleated porcine eyes for lamellar keratotomy. After flap removal, the cutting edge and stromal bed were evaluated from scanning electron micrographs using an individualized scoring system. Four different settings of microkeratome parameters were compared. For each setting, eight cuts were evaluated (n=32). Results: Different oscillation frequencies and head-advance speeds did not influence the cutting qualities. A higher oscillation/feed rate ratio seemed to be advantageous for a smoother interface. Concerning different cuttings heads, a deeper keratotomy led to sharper cutting edges. The thinner the flap, the more irregularities in the stromal bed appeared. Complications did not occur. Conclusion: The Carriazo-Pendular microkeratome is a safe tool with which to create a LASIK flap and is a good alternative to a costly femtosecond laser. Deeper keratotomies, as well as the use of a higher oscillation/feed rate quotient, improve the cutting quality. Keywords: laser-assisted in situ keratomileusis (LASIK), microkeratome, stromal bed quality, surface regularity, Descemet's stripping automated endothelial keratoplasty (DSAEK), scanning electron microscopy (SEM)http://www.dovepress.com/influence-of-microkeratome-parameters-on-the-stromal-bed-and-flap-edge-a15305
collection DOAJ
language English
format Article
sources DOAJ
author Heichel J
Wilhelm F
Kunert KS
Schlueter R
Stuhltraeger U
Hammer T
spellingShingle Heichel J
Wilhelm F
Kunert KS
Schlueter R
Stuhltraeger U
Hammer T
Influence of microkeratome parameters on the stromal bed and flap edge quality in laser in situ keratomileusis
Clinical Ophthalmology
author_facet Heichel J
Wilhelm F
Kunert KS
Schlueter R
Stuhltraeger U
Hammer T
author_sort Heichel J
title Influence of microkeratome parameters on the stromal bed and flap edge quality in laser in situ keratomileusis
title_short Influence of microkeratome parameters on the stromal bed and flap edge quality in laser in situ keratomileusis
title_full Influence of microkeratome parameters on the stromal bed and flap edge quality in laser in situ keratomileusis
title_fullStr Influence of microkeratome parameters on the stromal bed and flap edge quality in laser in situ keratomileusis
title_full_unstemmed Influence of microkeratome parameters on the stromal bed and flap edge quality in laser in situ keratomileusis
title_sort influence of microkeratome parameters on the stromal bed and flap edge quality in laser in situ keratomileusis
publisher Dove Medical Press
series Clinical Ophthalmology
issn 1177-5483
publishDate 2013-12-01
description Jens Heichel,1 Frank Wilhelm,2 Kathleen S Kunert,3 Rabea Schlueter,4 Ute Stuhltraeger,1 Thomas Hammer5 1Department of Ophthalmology, University Hospital of Martin Luther University Halle/Wittenberg, Halle (Saale), Germany; 2Augen im Zentrum, Greifswald, Germany; 3Department of Ophthalmology, Helios Klinikum Erfurt, Erfurt, Germany; 4Institute of Microbiology, Ernst-Moritz-Arndt-University, Greifswald, Germany; 5Augenzentrum Frohe Zukunft, Halle (Saale), Germany Purpose: Femtosecond lasers have become the standard for laser-assisted in situ keratomileusis (LASIK) flap creation, but advanced mechanical microkeratomes are still an alternative, more cost-effective way to create the flap. The SCHWIND Carriazo-Pendular microkeratome is one of the most commonly used microkeratomes. The influence of different cutting parameters (head-advance speeds, cutting heads) on morphology of LASIK cuts was investigated. Setting: Experimental study performed at the University Eye Hospital of the Martin Luther University Halle/Wittenberg, Halle (Saale), Germany. Methods: The Carriazo-Pendular microkeratome was used on freshly enucleated porcine eyes for lamellar keratotomy. After flap removal, the cutting edge and stromal bed were evaluated from scanning electron micrographs using an individualized scoring system. Four different settings of microkeratome parameters were compared. For each setting, eight cuts were evaluated (n=32). Results: Different oscillation frequencies and head-advance speeds did not influence the cutting qualities. A higher oscillation/feed rate ratio seemed to be advantageous for a smoother interface. Concerning different cuttings heads, a deeper keratotomy led to sharper cutting edges. The thinner the flap, the more irregularities in the stromal bed appeared. Complications did not occur. Conclusion: The Carriazo-Pendular microkeratome is a safe tool with which to create a LASIK flap and is a good alternative to a costly femtosecond laser. Deeper keratotomies, as well as the use of a higher oscillation/feed rate quotient, improve the cutting quality. Keywords: laser-assisted in situ keratomileusis (LASIK), microkeratome, stromal bed quality, surface regularity, Descemet's stripping automated endothelial keratoplasty (DSAEK), scanning electron microscopy (SEM)
url http://www.dovepress.com/influence-of-microkeratome-parameters-on-the-stromal-bed-and-flap-edge-a15305
work_keys_str_mv AT heichelj influenceofmicrokeratomeparametersonthestromalbedandflapedgequalityinlaserinsitukeratomileusis
AT wilhelmf influenceofmicrokeratomeparametersonthestromalbedandflapedgequalityinlaserinsitukeratomileusis
AT kunertks influenceofmicrokeratomeparametersonthestromalbedandflapedgequalityinlaserinsitukeratomileusis
AT schlueterr influenceofmicrokeratomeparametersonthestromalbedandflapedgequalityinlaserinsitukeratomileusis
AT stuhltraegeru influenceofmicrokeratomeparametersonthestromalbedandflapedgequalityinlaserinsitukeratomileusis
AT hammert influenceofmicrokeratomeparametersonthestromalbedandflapedgequalityinlaserinsitukeratomileusis
_version_ 1725542052279615488