Evaluating the Hemodynamical Response of a Cardiovascular System under Support of a Continuous Flow Left Ventricular Assist Device via Numerical Modeling and Simulations

Dilated cardiomyopathy is the most common type of the heart failure which can be characterized by impaired ventricular contractility. Mechanical circulatory support devices were introduced into practice for the heart failure patients to bridge the time between the decision to transplant and the actu...

Full description

Bibliographic Details
Main Authors: Selim Bozkurt, Koray K. Safak
Format: Article
Language:English
Published: Hindawi Limited 2013-01-01
Series:Computational and Mathematical Methods in Medicine
Online Access:http://dx.doi.org/10.1155/2013/986430
id doaj-753adb8db8d2491d842194582844ac8c
record_format Article
spelling doaj-753adb8db8d2491d842194582844ac8c2020-11-25T00:55:12ZengHindawi LimitedComputational and Mathematical Methods in Medicine1748-670X1748-67182013-01-01201310.1155/2013/986430986430Evaluating the Hemodynamical Response of a Cardiovascular System under Support of a Continuous Flow Left Ventricular Assist Device via Numerical Modeling and SimulationsSelim Bozkurt0Koray K. Safak1Department of Mechanical Engineering, Yeditepe University, 34755 Kadikoy, Istanbul, TurkeyDepartment of Mechanical Engineering, Yeditepe University, 34755 Kadikoy, Istanbul, TurkeyDilated cardiomyopathy is the most common type of the heart failure which can be characterized by impaired ventricular contractility. Mechanical circulatory support devices were introduced into practice for the heart failure patients to bridge the time between the decision to transplant and the actual transplantation which is not sufficient due to the state of donor organ supply. In this study, the hemodynamic response of a cardiovascular system that includes a dilated cardiomyopathic heart under support of a newly developed continuous flow left ventricular assist device—Heart Turcica Axial—was evaluated employing computer simulations. For the evaluation, a numerical model which describes the pressure-flow rate relations of Heart Turcica Axial, a cardiovascular system model describing the healthy and pathological hemodynamics, and a baroreflex model regulating the heart rate were used. Heart Turcica Axial was operated between 8000 rpm and 11000 rpm speeds with 1000 rpm increments for assessing the pump performance and response of the cardiovascular system. The results also give an insight about the range of the possible operating speeds of Heart Turcica Axial in a clinical application. Based on the findings, operating speed of Heart Turcica Axial should be between 10000 rpm and 11000 rpm.http://dx.doi.org/10.1155/2013/986430
collection DOAJ
language English
format Article
sources DOAJ
author Selim Bozkurt
Koray K. Safak
spellingShingle Selim Bozkurt
Koray K. Safak
Evaluating the Hemodynamical Response of a Cardiovascular System under Support of a Continuous Flow Left Ventricular Assist Device via Numerical Modeling and Simulations
Computational and Mathematical Methods in Medicine
author_facet Selim Bozkurt
Koray K. Safak
author_sort Selim Bozkurt
title Evaluating the Hemodynamical Response of a Cardiovascular System under Support of a Continuous Flow Left Ventricular Assist Device via Numerical Modeling and Simulations
title_short Evaluating the Hemodynamical Response of a Cardiovascular System under Support of a Continuous Flow Left Ventricular Assist Device via Numerical Modeling and Simulations
title_full Evaluating the Hemodynamical Response of a Cardiovascular System under Support of a Continuous Flow Left Ventricular Assist Device via Numerical Modeling and Simulations
title_fullStr Evaluating the Hemodynamical Response of a Cardiovascular System under Support of a Continuous Flow Left Ventricular Assist Device via Numerical Modeling and Simulations
title_full_unstemmed Evaluating the Hemodynamical Response of a Cardiovascular System under Support of a Continuous Flow Left Ventricular Assist Device via Numerical Modeling and Simulations
title_sort evaluating the hemodynamical response of a cardiovascular system under support of a continuous flow left ventricular assist device via numerical modeling and simulations
publisher Hindawi Limited
series Computational and Mathematical Methods in Medicine
issn 1748-670X
1748-6718
publishDate 2013-01-01
description Dilated cardiomyopathy is the most common type of the heart failure which can be characterized by impaired ventricular contractility. Mechanical circulatory support devices were introduced into practice for the heart failure patients to bridge the time between the decision to transplant and the actual transplantation which is not sufficient due to the state of donor organ supply. In this study, the hemodynamic response of a cardiovascular system that includes a dilated cardiomyopathic heart under support of a newly developed continuous flow left ventricular assist device—Heart Turcica Axial—was evaluated employing computer simulations. For the evaluation, a numerical model which describes the pressure-flow rate relations of Heart Turcica Axial, a cardiovascular system model describing the healthy and pathological hemodynamics, and a baroreflex model regulating the heart rate were used. Heart Turcica Axial was operated between 8000 rpm and 11000 rpm speeds with 1000 rpm increments for assessing the pump performance and response of the cardiovascular system. The results also give an insight about the range of the possible operating speeds of Heart Turcica Axial in a clinical application. Based on the findings, operating speed of Heart Turcica Axial should be between 10000 rpm and 11000 rpm.
url http://dx.doi.org/10.1155/2013/986430
work_keys_str_mv AT selimbozkurt evaluatingthehemodynamicalresponseofacardiovascularsystemundersupportofacontinuousflowleftventricularassistdevicevianumericalmodelingandsimulations
AT korayksafak evaluatingthehemodynamicalresponseofacardiovascularsystemundersupportofacontinuousflowleftventricularassistdevicevianumericalmodelingandsimulations
_version_ 1725231408685776896