Experimental Study on Pressure Distribution and Flow Coefficient of Globe Valve

In this study, the pressure distribution and flow coefficient of a globe valve are investigated with a series of experiments conducted in a flow test loop. The experiments are performed on a three-inch model test valve from an eight-inch ANSI (American National Standards Institute) B16.11—Class 2500...

Full description

Bibliographic Details
Main Authors: Quang Khai Nguyen, Kwang Hyo Jung, Gang Nam Lee, Sung Bu Suh, Peter To
Format: Article
Language:English
Published: MDPI AG 2020-07-01
Series:Processes
Subjects:
Online Access:https://www.mdpi.com/2227-9717/8/7/875
Description
Summary:In this study, the pressure distribution and flow coefficient of a globe valve are investigated with a series of experiments conducted in a flow test loop. The experiments are performed on a three-inch model test valve from an eight-inch ANSI (American National Standards Institute) B16.11—Class 2500# prototype globe valve with various pump speeds and full range of valve openings. Both inherent and installed flow characteristics are measured, and the results show that the flow coefficient depends not only on the valve geometry and valve opening but also on the Reynolds number. When the Reynolds number exceeds a certain value, the flow coefficients are stable. In addition, the pressures at different positions in the upstream and the downstream of the valve are measured and compared with recommendation per ANSI/ISA-75.01 standard. The results show that, in single-phase flow, the discrepancies in pressure between different measurement locations within close range of 10 nominal diameter from the valve are inconsiderable.