Effects of the Sn100 kVp Tube Voltage Mode on the Radiation Dose and Image Quality of Dual-Source Computed Tomography Pulmonary Angiography

Wei-Guo Zhang,1,* Jia-Ping Liu,2,* Xiu-Qin Jia,1 Ji-Yang Zhang,1 Xiang-Nan Li,1 Qi Yang1 1Department of Radiology, Beijing Chaoyang Hospital, Capital Medical University, Beijing, 100020, People’s Republic of China; 2Department of Radiology, Beijing Xiongke Hospital, Capital Medical Univers...

Full description

Bibliographic Details
Main Authors: Zhang WG, Liu JP, Jia XQ, Zhang JY, Li XN, Yang Q
Format: Article
Language:English
Published: Dove Medical Press 2021-03-01
Series:International Journal of General Medicine
Subjects:
Online Access:https://www.dovepress.com/effects-of-the-sn100-kvp-tube-voltage-mode-on-the-radiation-dose-and-i-peer-reviewed-article-IJGM
id doaj-7490926b3e2344978bf211afa7f67fe4
record_format Article
spelling doaj-7490926b3e2344978bf211afa7f67fe42021-03-28T19:57:49ZengDove Medical PressInternational Journal of General Medicine1178-70742021-03-01Volume 141033103963397Effects of the Sn100 kVp Tube Voltage Mode on the Radiation Dose and Image Quality of Dual-Source Computed Tomography Pulmonary AngiographyZhang WGLiu JPJia XQZhang JYLi XNYang QWei-Guo Zhang,1,* Jia-Ping Liu,2,* Xiu-Qin Jia,1 Ji-Yang Zhang,1 Xiang-Nan Li,1 Qi Yang1 1Department of Radiology, Beijing Chaoyang Hospital, Capital Medical University, Beijing, 100020, People’s Republic of China; 2Department of Radiology, Beijing Xiongke Hospital, Capital Medical University, Beijing, 100049, People’s Republic of China*These authors contributed equally to this workCorrespondence: Qi YangDepartment of Radiology, Beijing Chaoyang Hospital, Capital Medical University, No. 8 Gongti South Road, Chaoyang District, Beijing, 100020, People’s Republic of ChinaTel/Fax +86-85231928Email qiyang856@163.comObjective: This study aimed to investigate the effects of the Sn100 kVp tube voltage mode on the image quality and radiation dose of computed tomography pulmonary angiography (CTPA).Methods: A total of 145 patients who underwent CTPA were randomly divided into five groups: control group (120 kVp, 150 mAs), test group A (Sn100 kVp, 270 mAs), test group B (120 kVp, 30 mAs), test group C (70 kVp, 150 mAs), and test group D (80 kVp, 70 mAs). After image post-processing, the image quality and radiation dose of each group were analyzed.Results: The computed tomography values of images in the four test groups were more than 250 HU, which met the criteria for diagnosis. The signal-to-noise ratio and contrast-to-noise ratio of the images in the four test groups were lower than those in the control group. The radiation dose in each test group was lower than in the control group. The radiation dose was lowest in test group A.Conclusion: The Sn100 kVp energy spectrum purification protocol can meet the requirements for clinical diagnosis, ensure image quality, and reduce the dose of radiation that patients receive.Keywords: Sn100 kVp, CTPA, radiation dose, pulmonary embolism, dual-source CThttps://www.dovepress.com/effects-of-the-sn100-kvp-tube-voltage-mode-on-the-radiation-dose-and-i-peer-reviewed-article-IJGMsn100 kvpctparadiation dosepulmonary embolismdual-source ct
collection DOAJ
language English
format Article
sources DOAJ
author Zhang WG
Liu JP
Jia XQ
Zhang JY
Li XN
Yang Q
spellingShingle Zhang WG
Liu JP
Jia XQ
Zhang JY
Li XN
Yang Q
Effects of the Sn100 kVp Tube Voltage Mode on the Radiation Dose and Image Quality of Dual-Source Computed Tomography Pulmonary Angiography
International Journal of General Medicine
sn100 kvp
ctpa
radiation dose
pulmonary embolism
dual-source ct
author_facet Zhang WG
Liu JP
Jia XQ
Zhang JY
Li XN
Yang Q
author_sort Zhang WG
title Effects of the Sn100 kVp Tube Voltage Mode on the Radiation Dose and Image Quality of Dual-Source Computed Tomography Pulmonary Angiography
title_short Effects of the Sn100 kVp Tube Voltage Mode on the Radiation Dose and Image Quality of Dual-Source Computed Tomography Pulmonary Angiography
title_full Effects of the Sn100 kVp Tube Voltage Mode on the Radiation Dose and Image Quality of Dual-Source Computed Tomography Pulmonary Angiography
title_fullStr Effects of the Sn100 kVp Tube Voltage Mode on the Radiation Dose and Image Quality of Dual-Source Computed Tomography Pulmonary Angiography
title_full_unstemmed Effects of the Sn100 kVp Tube Voltage Mode on the Radiation Dose and Image Quality of Dual-Source Computed Tomography Pulmonary Angiography
title_sort effects of the sn100 kvp tube voltage mode on the radiation dose and image quality of dual-source computed tomography pulmonary angiography
publisher Dove Medical Press
series International Journal of General Medicine
issn 1178-7074
publishDate 2021-03-01
description Wei-Guo Zhang,1,* Jia-Ping Liu,2,* Xiu-Qin Jia,1 Ji-Yang Zhang,1 Xiang-Nan Li,1 Qi Yang1 1Department of Radiology, Beijing Chaoyang Hospital, Capital Medical University, Beijing, 100020, People’s Republic of China; 2Department of Radiology, Beijing Xiongke Hospital, Capital Medical University, Beijing, 100049, People’s Republic of China*These authors contributed equally to this workCorrespondence: Qi YangDepartment of Radiology, Beijing Chaoyang Hospital, Capital Medical University, No. 8 Gongti South Road, Chaoyang District, Beijing, 100020, People’s Republic of ChinaTel/Fax +86-85231928Email qiyang856@163.comObjective: This study aimed to investigate the effects of the Sn100 kVp tube voltage mode on the image quality and radiation dose of computed tomography pulmonary angiography (CTPA).Methods: A total of 145 patients who underwent CTPA were randomly divided into five groups: control group (120 kVp, 150 mAs), test group A (Sn100 kVp, 270 mAs), test group B (120 kVp, 30 mAs), test group C (70 kVp, 150 mAs), and test group D (80 kVp, 70 mAs). After image post-processing, the image quality and radiation dose of each group were analyzed.Results: The computed tomography values of images in the four test groups were more than 250 HU, which met the criteria for diagnosis. The signal-to-noise ratio and contrast-to-noise ratio of the images in the four test groups were lower than those in the control group. The radiation dose in each test group was lower than in the control group. The radiation dose was lowest in test group A.Conclusion: The Sn100 kVp energy spectrum purification protocol can meet the requirements for clinical diagnosis, ensure image quality, and reduce the dose of radiation that patients receive.Keywords: Sn100 kVp, CTPA, radiation dose, pulmonary embolism, dual-source CT
topic sn100 kvp
ctpa
radiation dose
pulmonary embolism
dual-source ct
url https://www.dovepress.com/effects-of-the-sn100-kvp-tube-voltage-mode-on-the-radiation-dose-and-i-peer-reviewed-article-IJGM
work_keys_str_mv AT zhangwg effectsofthesn100kvptubevoltagemodeontheradiationdoseandimagequalityofdualsourcecomputedtomographypulmonaryangiography
AT liujp effectsofthesn100kvptubevoltagemodeontheradiationdoseandimagequalityofdualsourcecomputedtomographypulmonaryangiography
AT jiaxq effectsofthesn100kvptubevoltagemodeontheradiationdoseandimagequalityofdualsourcecomputedtomographypulmonaryangiography
AT zhangjy effectsofthesn100kvptubevoltagemodeontheradiationdoseandimagequalityofdualsourcecomputedtomographypulmonaryangiography
AT lixn effectsofthesn100kvptubevoltagemodeontheradiationdoseandimagequalityofdualsourcecomputedtomographypulmonaryangiography
AT yangq effectsofthesn100kvptubevoltagemodeontheradiationdoseandimagequalityofdualsourcecomputedtomographypulmonaryangiography
_version_ 1724199509518450688