Effects of the Sn100 kVp Tube Voltage Mode on the Radiation Dose and Image Quality of Dual-Source Computed Tomography Pulmonary Angiography
Wei-Guo Zhang,1,* Jia-Ping Liu,2,* Xiu-Qin Jia,1 Ji-Yang Zhang,1 Xiang-Nan Li,1 Qi Yang1 1Department of Radiology, Beijing Chaoyang Hospital, Capital Medical University, Beijing, 100020, People’s Republic of China; 2Department of Radiology, Beijing Xiongke Hospital, Capital Medical Univers...
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Dove Medical Press
2021-03-01
|
Series: | International Journal of General Medicine |
Subjects: | |
Online Access: | https://www.dovepress.com/effects-of-the-sn100-kvp-tube-voltage-mode-on-the-radiation-dose-and-i-peer-reviewed-article-IJGM |
id |
doaj-7490926b3e2344978bf211afa7f67fe4 |
---|---|
record_format |
Article |
spelling |
doaj-7490926b3e2344978bf211afa7f67fe42021-03-28T19:57:49ZengDove Medical PressInternational Journal of General Medicine1178-70742021-03-01Volume 141033103963397Effects of the Sn100 kVp Tube Voltage Mode on the Radiation Dose and Image Quality of Dual-Source Computed Tomography Pulmonary AngiographyZhang WGLiu JPJia XQZhang JYLi XNYang QWei-Guo Zhang,1,* Jia-Ping Liu,2,* Xiu-Qin Jia,1 Ji-Yang Zhang,1 Xiang-Nan Li,1 Qi Yang1 1Department of Radiology, Beijing Chaoyang Hospital, Capital Medical University, Beijing, 100020, People’s Republic of China; 2Department of Radiology, Beijing Xiongke Hospital, Capital Medical University, Beijing, 100049, People’s Republic of China*These authors contributed equally to this workCorrespondence: Qi YangDepartment of Radiology, Beijing Chaoyang Hospital, Capital Medical University, No. 8 Gongti South Road, Chaoyang District, Beijing, 100020, People’s Republic of ChinaTel/Fax +86-85231928Email qiyang856@163.comObjective: This study aimed to investigate the effects of the Sn100 kVp tube voltage mode on the image quality and radiation dose of computed tomography pulmonary angiography (CTPA).Methods: A total of 145 patients who underwent CTPA were randomly divided into five groups: control group (120 kVp, 150 mAs), test group A (Sn100 kVp, 270 mAs), test group B (120 kVp, 30 mAs), test group C (70 kVp, 150 mAs), and test group D (80 kVp, 70 mAs). After image post-processing, the image quality and radiation dose of each group were analyzed.Results: The computed tomography values of images in the four test groups were more than 250 HU, which met the criteria for diagnosis. The signal-to-noise ratio and contrast-to-noise ratio of the images in the four test groups were lower than those in the control group. The radiation dose in each test group was lower than in the control group. The radiation dose was lowest in test group A.Conclusion: The Sn100 kVp energy spectrum purification protocol can meet the requirements for clinical diagnosis, ensure image quality, and reduce the dose of radiation that patients receive.Keywords: Sn100 kVp, CTPA, radiation dose, pulmonary embolism, dual-source CThttps://www.dovepress.com/effects-of-the-sn100-kvp-tube-voltage-mode-on-the-radiation-dose-and-i-peer-reviewed-article-IJGMsn100 kvpctparadiation dosepulmonary embolismdual-source ct |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Zhang WG Liu JP Jia XQ Zhang JY Li XN Yang Q |
spellingShingle |
Zhang WG Liu JP Jia XQ Zhang JY Li XN Yang Q Effects of the Sn100 kVp Tube Voltage Mode on the Radiation Dose and Image Quality of Dual-Source Computed Tomography Pulmonary Angiography International Journal of General Medicine sn100 kvp ctpa radiation dose pulmonary embolism dual-source ct |
author_facet |
Zhang WG Liu JP Jia XQ Zhang JY Li XN Yang Q |
author_sort |
Zhang WG |
title |
Effects of the Sn100 kVp Tube Voltage Mode on the Radiation Dose and Image Quality of Dual-Source Computed Tomography Pulmonary Angiography |
title_short |
Effects of the Sn100 kVp Tube Voltage Mode on the Radiation Dose and Image Quality of Dual-Source Computed Tomography Pulmonary Angiography |
title_full |
Effects of the Sn100 kVp Tube Voltage Mode on the Radiation Dose and Image Quality of Dual-Source Computed Tomography Pulmonary Angiography |
title_fullStr |
Effects of the Sn100 kVp Tube Voltage Mode on the Radiation Dose and Image Quality of Dual-Source Computed Tomography Pulmonary Angiography |
title_full_unstemmed |
Effects of the Sn100 kVp Tube Voltage Mode on the Radiation Dose and Image Quality of Dual-Source Computed Tomography Pulmonary Angiography |
title_sort |
effects of the sn100 kvp tube voltage mode on the radiation dose and image quality of dual-source computed tomography pulmonary angiography |
publisher |
Dove Medical Press |
series |
International Journal of General Medicine |
issn |
1178-7074 |
publishDate |
2021-03-01 |
description |
Wei-Guo Zhang,1,* Jia-Ping Liu,2,* Xiu-Qin Jia,1 Ji-Yang Zhang,1 Xiang-Nan Li,1 Qi Yang1 1Department of Radiology, Beijing Chaoyang Hospital, Capital Medical University, Beijing, 100020, People’s Republic of China; 2Department of Radiology, Beijing Xiongke Hospital, Capital Medical University, Beijing, 100049, People’s Republic of China*These authors contributed equally to this workCorrespondence: Qi YangDepartment of Radiology, Beijing Chaoyang Hospital, Capital Medical University, No. 8 Gongti South Road, Chaoyang District, Beijing, 100020, People’s Republic of ChinaTel/Fax +86-85231928Email qiyang856@163.comObjective: This study aimed to investigate the effects of the Sn100 kVp tube voltage mode on the image quality and radiation dose of computed tomography pulmonary angiography (CTPA).Methods: A total of 145 patients who underwent CTPA were randomly divided into five groups: control group (120 kVp, 150 mAs), test group A (Sn100 kVp, 270 mAs), test group B (120 kVp, 30 mAs), test group C (70 kVp, 150 mAs), and test group D (80 kVp, 70 mAs). After image post-processing, the image quality and radiation dose of each group were analyzed.Results: The computed tomography values of images in the four test groups were more than 250 HU, which met the criteria for diagnosis. The signal-to-noise ratio and contrast-to-noise ratio of the images in the four test groups were lower than those in the control group. The radiation dose in each test group was lower than in the control group. The radiation dose was lowest in test group A.Conclusion: The Sn100 kVp energy spectrum purification protocol can meet the requirements for clinical diagnosis, ensure image quality, and reduce the dose of radiation that patients receive.Keywords: Sn100 kVp, CTPA, radiation dose, pulmonary embolism, dual-source CT |
topic |
sn100 kvp ctpa radiation dose pulmonary embolism dual-source ct |
url |
https://www.dovepress.com/effects-of-the-sn100-kvp-tube-voltage-mode-on-the-radiation-dose-and-i-peer-reviewed-article-IJGM |
work_keys_str_mv |
AT zhangwg effectsofthesn100kvptubevoltagemodeontheradiationdoseandimagequalityofdualsourcecomputedtomographypulmonaryangiography AT liujp effectsofthesn100kvptubevoltagemodeontheradiationdoseandimagequalityofdualsourcecomputedtomographypulmonaryangiography AT jiaxq effectsofthesn100kvptubevoltagemodeontheradiationdoseandimagequalityofdualsourcecomputedtomographypulmonaryangiography AT zhangjy effectsofthesn100kvptubevoltagemodeontheradiationdoseandimagequalityofdualsourcecomputedtomographypulmonaryangiography AT lixn effectsofthesn100kvptubevoltagemodeontheradiationdoseandimagequalityofdualsourcecomputedtomographypulmonaryangiography AT yangq effectsofthesn100kvptubevoltagemodeontheradiationdoseandimagequalityofdualsourcecomputedtomographypulmonaryangiography |
_version_ |
1724199509518450688 |