Pharmacokinetics and bioequivalence assessment of optimized directly compressible Aceclofenac (100 mg) tablet formulation in healthy human subjects.

The aim of the study was to determine the various pharmacokinetic parameters of the newly developed cost-effective aceclofenac 100 mg tablet formulation (F-15) and to establish the bioequivalence against the marketed brand (ACEMED). Both products (test and reference) were given to 12 healthy non-smo...

Full description

Bibliographic Details
Main Authors: Rabia Bushra, Muhammad Harris Shoaib, Huma Ali, Sana Ghayas
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2020-01-01
Series:PLoS ONE
Online Access:https://doi.org/10.1371/journal.pone.0238951
id doaj-7428b503aeec4053b17c790b447424eb
record_format Article
spelling doaj-7428b503aeec4053b17c790b447424eb2021-03-03T22:05:16ZengPublic Library of Science (PLoS)PLoS ONE1932-62032020-01-01159e023895110.1371/journal.pone.0238951Pharmacokinetics and bioequivalence assessment of optimized directly compressible Aceclofenac (100 mg) tablet formulation in healthy human subjects.Rabia BushraMuhammad Harris ShoaibHuma AliSana GhayasThe aim of the study was to determine the various pharmacokinetic parameters of the newly developed cost-effective aceclofenac 100 mg tablet formulation (F-15) and to establish the bioequivalence against the marketed brand (ACEMED). Both products (test and reference) were given to 12 healthy non-smokers male subjects with overnight fasting of >10hr. The study was a randomized, single-dose, open-label, two sequence, and two treatment crossover design, with a washout period of 2 weeks. Blood samples (5 mL) from the human subjects were collected before (0 hr) and after drug administration at 13different time points (0.5, 1, 1.5, 2, 2.5, 3, 3.5, 4, 5, 6, 8, 12 and 18 hrs). The drug plasma concentration was analyzed by a validated RP-HPLC method using a solvent system containing acetonitrile and deionized water (60:40% v/v). Linearity was found to be 0.999 over the drug concentration range of 50μg/mL to 0.05μg/mL with LLOQ and LOD of 0.05μg/mL and 0.025μg/mL respectively. Non-compartmental pharmacokinetic analysis was performed using Kinetica® (ver. 5.1) software. Using the log-transformed data Cmax, AUC0-t, AUC0-∞, AUMCtot, and MRT were calculated. The Cmax of the test and brand was found to be 8.629±1.251μg/mL and 8.478±0.913μg/mL. The AUC0-t and AUC0-∞ of the test and the reference were computed to be 20.890 ±2.2021μg/mL.h, 23.272 ±1.914 μg/mL.h and 19.850 ±2.911 μg/mL.h, 22.890 ± 2.110 μg/mL.h correspondingly. Two-way analysis of variance (ANOVA) test and two one-sided t-test (p>0.05; non-significant) were applied to assess the variation in the period, sequence, subjects, and treatment. Geometric mean ratios for above mentioned pharmacokinetic parameters of reference/test were found within the acceptable FDA limits of 80-125% using 90% CI. There was no inter and intrasubject variation (p> 0.05) that was observed. Therefore, the directly compressible aceclofenac (100 mg) test formulation and the commercial reference tablets were declared to be biosimilar.https://doi.org/10.1371/journal.pone.0238951
collection DOAJ
language English
format Article
sources DOAJ
author Rabia Bushra
Muhammad Harris Shoaib
Huma Ali
Sana Ghayas
spellingShingle Rabia Bushra
Muhammad Harris Shoaib
Huma Ali
Sana Ghayas
Pharmacokinetics and bioequivalence assessment of optimized directly compressible Aceclofenac (100 mg) tablet formulation in healthy human subjects.
PLoS ONE
author_facet Rabia Bushra
Muhammad Harris Shoaib
Huma Ali
Sana Ghayas
author_sort Rabia Bushra
title Pharmacokinetics and bioequivalence assessment of optimized directly compressible Aceclofenac (100 mg) tablet formulation in healthy human subjects.
title_short Pharmacokinetics and bioequivalence assessment of optimized directly compressible Aceclofenac (100 mg) tablet formulation in healthy human subjects.
title_full Pharmacokinetics and bioequivalence assessment of optimized directly compressible Aceclofenac (100 mg) tablet formulation in healthy human subjects.
title_fullStr Pharmacokinetics and bioequivalence assessment of optimized directly compressible Aceclofenac (100 mg) tablet formulation in healthy human subjects.
title_full_unstemmed Pharmacokinetics and bioequivalence assessment of optimized directly compressible Aceclofenac (100 mg) tablet formulation in healthy human subjects.
title_sort pharmacokinetics and bioequivalence assessment of optimized directly compressible aceclofenac (100 mg) tablet formulation in healthy human subjects.
publisher Public Library of Science (PLoS)
series PLoS ONE
issn 1932-6203
publishDate 2020-01-01
description The aim of the study was to determine the various pharmacokinetic parameters of the newly developed cost-effective aceclofenac 100 mg tablet formulation (F-15) and to establish the bioequivalence against the marketed brand (ACEMED). Both products (test and reference) were given to 12 healthy non-smokers male subjects with overnight fasting of >10hr. The study was a randomized, single-dose, open-label, two sequence, and two treatment crossover design, with a washout period of 2 weeks. Blood samples (5 mL) from the human subjects were collected before (0 hr) and after drug administration at 13different time points (0.5, 1, 1.5, 2, 2.5, 3, 3.5, 4, 5, 6, 8, 12 and 18 hrs). The drug plasma concentration was analyzed by a validated RP-HPLC method using a solvent system containing acetonitrile and deionized water (60:40% v/v). Linearity was found to be 0.999 over the drug concentration range of 50μg/mL to 0.05μg/mL with LLOQ and LOD of 0.05μg/mL and 0.025μg/mL respectively. Non-compartmental pharmacokinetic analysis was performed using Kinetica® (ver. 5.1) software. Using the log-transformed data Cmax, AUC0-t, AUC0-∞, AUMCtot, and MRT were calculated. The Cmax of the test and brand was found to be 8.629±1.251μg/mL and 8.478±0.913μg/mL. The AUC0-t and AUC0-∞ of the test and the reference were computed to be 20.890 ±2.2021μg/mL.h, 23.272 ±1.914 μg/mL.h and 19.850 ±2.911 μg/mL.h, 22.890 ± 2.110 μg/mL.h correspondingly. Two-way analysis of variance (ANOVA) test and two one-sided t-test (p>0.05; non-significant) were applied to assess the variation in the period, sequence, subjects, and treatment. Geometric mean ratios for above mentioned pharmacokinetic parameters of reference/test were found within the acceptable FDA limits of 80-125% using 90% CI. There was no inter and intrasubject variation (p> 0.05) that was observed. Therefore, the directly compressible aceclofenac (100 mg) test formulation and the commercial reference tablets were declared to be biosimilar.
url https://doi.org/10.1371/journal.pone.0238951
work_keys_str_mv AT rabiabushra pharmacokineticsandbioequivalenceassessmentofoptimizeddirectlycompressibleaceclofenac100mgtabletformulationinhealthyhumansubjects
AT muhammadharrisshoaib pharmacokineticsandbioequivalenceassessmentofoptimizeddirectlycompressibleaceclofenac100mgtabletformulationinhealthyhumansubjects
AT humaali pharmacokineticsandbioequivalenceassessmentofoptimizeddirectlycompressibleaceclofenac100mgtabletformulationinhealthyhumansubjects
AT sanaghayas pharmacokineticsandbioequivalenceassessmentofoptimizeddirectlycompressibleaceclofenac100mgtabletformulationinhealthyhumansubjects
_version_ 1714813468905832448