Pharmacokinetics and bioequivalence assessment of optimized directly compressible Aceclofenac (100 mg) tablet formulation in healthy human subjects.
The aim of the study was to determine the various pharmacokinetic parameters of the newly developed cost-effective aceclofenac 100 mg tablet formulation (F-15) and to establish the bioequivalence against the marketed brand (ACEMED). Both products (test and reference) were given to 12 healthy non-smo...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Public Library of Science (PLoS)
2020-01-01
|
Series: | PLoS ONE |
Online Access: | https://doi.org/10.1371/journal.pone.0238951 |
id |
doaj-7428b503aeec4053b17c790b447424eb |
---|---|
record_format |
Article |
spelling |
doaj-7428b503aeec4053b17c790b447424eb2021-03-03T22:05:16ZengPublic Library of Science (PLoS)PLoS ONE1932-62032020-01-01159e023895110.1371/journal.pone.0238951Pharmacokinetics and bioequivalence assessment of optimized directly compressible Aceclofenac (100 mg) tablet formulation in healthy human subjects.Rabia BushraMuhammad Harris ShoaibHuma AliSana GhayasThe aim of the study was to determine the various pharmacokinetic parameters of the newly developed cost-effective aceclofenac 100 mg tablet formulation (F-15) and to establish the bioequivalence against the marketed brand (ACEMED). Both products (test and reference) were given to 12 healthy non-smokers male subjects with overnight fasting of >10hr. The study was a randomized, single-dose, open-label, two sequence, and two treatment crossover design, with a washout period of 2 weeks. Blood samples (5 mL) from the human subjects were collected before (0 hr) and after drug administration at 13different time points (0.5, 1, 1.5, 2, 2.5, 3, 3.5, 4, 5, 6, 8, 12 and 18 hrs). The drug plasma concentration was analyzed by a validated RP-HPLC method using a solvent system containing acetonitrile and deionized water (60:40% v/v). Linearity was found to be 0.999 over the drug concentration range of 50μg/mL to 0.05μg/mL with LLOQ and LOD of 0.05μg/mL and 0.025μg/mL respectively. Non-compartmental pharmacokinetic analysis was performed using Kinetica® (ver. 5.1) software. Using the log-transformed data Cmax, AUC0-t, AUC0-∞, AUMCtot, and MRT were calculated. The Cmax of the test and brand was found to be 8.629±1.251μg/mL and 8.478±0.913μg/mL. The AUC0-t and AUC0-∞ of the test and the reference were computed to be 20.890 ±2.2021μg/mL.h, 23.272 ±1.914 μg/mL.h and 19.850 ±2.911 μg/mL.h, 22.890 ± 2.110 μg/mL.h correspondingly. Two-way analysis of variance (ANOVA) test and two one-sided t-test (p>0.05; non-significant) were applied to assess the variation in the period, sequence, subjects, and treatment. Geometric mean ratios for above mentioned pharmacokinetic parameters of reference/test were found within the acceptable FDA limits of 80-125% using 90% CI. There was no inter and intrasubject variation (p> 0.05) that was observed. Therefore, the directly compressible aceclofenac (100 mg) test formulation and the commercial reference tablets were declared to be biosimilar.https://doi.org/10.1371/journal.pone.0238951 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Rabia Bushra Muhammad Harris Shoaib Huma Ali Sana Ghayas |
spellingShingle |
Rabia Bushra Muhammad Harris Shoaib Huma Ali Sana Ghayas Pharmacokinetics and bioequivalence assessment of optimized directly compressible Aceclofenac (100 mg) tablet formulation in healthy human subjects. PLoS ONE |
author_facet |
Rabia Bushra Muhammad Harris Shoaib Huma Ali Sana Ghayas |
author_sort |
Rabia Bushra |
title |
Pharmacokinetics and bioequivalence assessment of optimized directly compressible Aceclofenac (100 mg) tablet formulation in healthy human subjects. |
title_short |
Pharmacokinetics and bioequivalence assessment of optimized directly compressible Aceclofenac (100 mg) tablet formulation in healthy human subjects. |
title_full |
Pharmacokinetics and bioequivalence assessment of optimized directly compressible Aceclofenac (100 mg) tablet formulation in healthy human subjects. |
title_fullStr |
Pharmacokinetics and bioequivalence assessment of optimized directly compressible Aceclofenac (100 mg) tablet formulation in healthy human subjects. |
title_full_unstemmed |
Pharmacokinetics and bioequivalence assessment of optimized directly compressible Aceclofenac (100 mg) tablet formulation in healthy human subjects. |
title_sort |
pharmacokinetics and bioequivalence assessment of optimized directly compressible aceclofenac (100 mg) tablet formulation in healthy human subjects. |
publisher |
Public Library of Science (PLoS) |
series |
PLoS ONE |
issn |
1932-6203 |
publishDate |
2020-01-01 |
description |
The aim of the study was to determine the various pharmacokinetic parameters of the newly developed cost-effective aceclofenac 100 mg tablet formulation (F-15) and to establish the bioequivalence against the marketed brand (ACEMED). Both products (test and reference) were given to 12 healthy non-smokers male subjects with overnight fasting of >10hr. The study was a randomized, single-dose, open-label, two sequence, and two treatment crossover design, with a washout period of 2 weeks. Blood samples (5 mL) from the human subjects were collected before (0 hr) and after drug administration at 13different time points (0.5, 1, 1.5, 2, 2.5, 3, 3.5, 4, 5, 6, 8, 12 and 18 hrs). The drug plasma concentration was analyzed by a validated RP-HPLC method using a solvent system containing acetonitrile and deionized water (60:40% v/v). Linearity was found to be 0.999 over the drug concentration range of 50μg/mL to 0.05μg/mL with LLOQ and LOD of 0.05μg/mL and 0.025μg/mL respectively. Non-compartmental pharmacokinetic analysis was performed using Kinetica® (ver. 5.1) software. Using the log-transformed data Cmax, AUC0-t, AUC0-∞, AUMCtot, and MRT were calculated. The Cmax of the test and brand was found to be 8.629±1.251μg/mL and 8.478±0.913μg/mL. The AUC0-t and AUC0-∞ of the test and the reference were computed to be 20.890 ±2.2021μg/mL.h, 23.272 ±1.914 μg/mL.h and 19.850 ±2.911 μg/mL.h, 22.890 ± 2.110 μg/mL.h correspondingly. Two-way analysis of variance (ANOVA) test and two one-sided t-test (p>0.05; non-significant) were applied to assess the variation in the period, sequence, subjects, and treatment. Geometric mean ratios for above mentioned pharmacokinetic parameters of reference/test were found within the acceptable FDA limits of 80-125% using 90% CI. There was no inter and intrasubject variation (p> 0.05) that was observed. Therefore, the directly compressible aceclofenac (100 mg) test formulation and the commercial reference tablets were declared to be biosimilar. |
url |
https://doi.org/10.1371/journal.pone.0238951 |
work_keys_str_mv |
AT rabiabushra pharmacokineticsandbioequivalenceassessmentofoptimizeddirectlycompressibleaceclofenac100mgtabletformulationinhealthyhumansubjects AT muhammadharrisshoaib pharmacokineticsandbioequivalenceassessmentofoptimizeddirectlycompressibleaceclofenac100mgtabletformulationinhealthyhumansubjects AT humaali pharmacokineticsandbioequivalenceassessmentofoptimizeddirectlycompressibleaceclofenac100mgtabletformulationinhealthyhumansubjects AT sanaghayas pharmacokineticsandbioequivalenceassessmentofoptimizeddirectlycompressibleaceclofenac100mgtabletformulationinhealthyhumansubjects |
_version_ |
1714813468905832448 |