Measurement of outdoor and indoor ambient gamma dose rate in Gorgan and Bandar-Torkman cities using gas and thermoluminescent dosimeters

Background and Objective: Human external exposure to natural radiation sources is much more than artificial radiation sources. In this study, external annual effective doses were estimated in cities of Gorgan and Bandar-Torkman by determining ambient gamma dose rate in indoor and outdoor spaces. Mat...

Full description

Bibliographic Details
Main Authors: B Pangh, R Khabaz, A Izadpanah
Format: Article
Language:fas
Published: Tehran University of Medical Sciences 2019-12-01
Series:سلامت و محیط
Subjects:
Online Access:http://ijhe.tums.ac.ir/article-1-6088-en.html
id doaj-7400597c78e84f51b4514dfe0da8d2a6
record_format Article
spelling doaj-7400597c78e84f51b4514dfe0da8d2a62021-09-05T04:05:43ZfasTehran University of Medical Sciencesسلامت و محیط2008-20292008-37182019-12-01123397408Measurement of outdoor and indoor ambient gamma dose rate in Gorgan and Bandar-Torkman cities using gas and thermoluminescent dosimetersB Pangh0R Khabaz1A Izadpanah2 Department of Physics, Faculty of Sciences, Golestan University, Gorgan, Iran Department of Physics, Faculty of Sciences, Golestan University, Gorgan, Iran Department of Physics, Faculty of Sciences, Golestan University, Gorgan, Iran Background and Objective: Human external exposure to natural radiation sources is much more than artificial radiation sources. In this study, external annual effective doses were estimated in cities of Gorgan and Bandar-Torkman by determining ambient gamma dose rate in indoor and outdoor spaces. Materials and Methods: Using an ionization chamber detector, the outdoor and indoor ambient gamma dose rate at 32 and 16 selected stations in Gorgan and Bandar-Torkman cities was measured for one hour, respectively. Indoor measurements were performed by 36 dosimeters in Gorgan and Bandar-Torkman cities in 11 and 6 residential buildings respectively using thermoluminescence dosimetry method. Results: The results of this study indicate that the ambient gamma dose rate in outdoor is a little more than this quantity in indoor space. The annual effective dose received by residents of Gorgan and Bandar-Torkman were 0.720 and 0.719 mSv, respectively. Conclusion: The annual effective dose received by residents of Gorgan and Bandar-Torkman cities is less than the worldwide average, and it is also less than the reference dose level for ordinary people (1 mSv).http://ijhe.tums.ac.ir/article-1-6088-en.htmlambient gammaexternal radiationeffective dosegorganbandar-torkaman
collection DOAJ
language fas
format Article
sources DOAJ
author B Pangh
R Khabaz
A Izadpanah
spellingShingle B Pangh
R Khabaz
A Izadpanah
Measurement of outdoor and indoor ambient gamma dose rate in Gorgan and Bandar-Torkman cities using gas and thermoluminescent dosimeters
سلامت و محیط
ambient gamma
external radiation
effective dose
gorgan
bandar-torkaman
author_facet B Pangh
R Khabaz
A Izadpanah
author_sort B Pangh
title Measurement of outdoor and indoor ambient gamma dose rate in Gorgan and Bandar-Torkman cities using gas and thermoluminescent dosimeters
title_short Measurement of outdoor and indoor ambient gamma dose rate in Gorgan and Bandar-Torkman cities using gas and thermoluminescent dosimeters
title_full Measurement of outdoor and indoor ambient gamma dose rate in Gorgan and Bandar-Torkman cities using gas and thermoluminescent dosimeters
title_fullStr Measurement of outdoor and indoor ambient gamma dose rate in Gorgan and Bandar-Torkman cities using gas and thermoluminescent dosimeters
title_full_unstemmed Measurement of outdoor and indoor ambient gamma dose rate in Gorgan and Bandar-Torkman cities using gas and thermoluminescent dosimeters
title_sort measurement of outdoor and indoor ambient gamma dose rate in gorgan and bandar-torkman cities using gas and thermoluminescent dosimeters
publisher Tehran University of Medical Sciences
series سلامت و محیط
issn 2008-2029
2008-3718
publishDate 2019-12-01
description Background and Objective: Human external exposure to natural radiation sources is much more than artificial radiation sources. In this study, external annual effective doses were estimated in cities of Gorgan and Bandar-Torkman by determining ambient gamma dose rate in indoor and outdoor spaces. Materials and Methods: Using an ionization chamber detector, the outdoor and indoor ambient gamma dose rate at 32 and 16 selected stations in Gorgan and Bandar-Torkman cities was measured for one hour, respectively. Indoor measurements were performed by 36 dosimeters in Gorgan and Bandar-Torkman cities in 11 and 6 residential buildings respectively using thermoluminescence dosimetry method. Results: The results of this study indicate that the ambient gamma dose rate in outdoor is a little more than this quantity in indoor space. The annual effective dose received by residents of Gorgan and Bandar-Torkman were 0.720 and 0.719 mSv, respectively. Conclusion: The annual effective dose received by residents of Gorgan and Bandar-Torkman cities is less than the worldwide average, and it is also less than the reference dose level for ordinary people (1 mSv).
topic ambient gamma
external radiation
effective dose
gorgan
bandar-torkaman
url http://ijhe.tums.ac.ir/article-1-6088-en.html
work_keys_str_mv AT bpangh measurementofoutdoorandindoorambientgammadoserateingorganandbandartorkmancitiesusinggasandthermoluminescentdosimeters
AT rkhabaz measurementofoutdoorandindoorambientgammadoserateingorganandbandartorkmancitiesusinggasandthermoluminescentdosimeters
AT aizadpanah measurementofoutdoorandindoorambientgammadoserateingorganandbandartorkmancitiesusinggasandthermoluminescentdosimeters
_version_ 1717814780223291392