An experimental study of the air humidification process using a membrane contactor
The article presents the results of the experimental examination of the effectiveness of air humidification using a membrane module. The construction of the membrane module and the measuring stand is also discussed. In order to assess the effectiveness of air humidification using the membrane module...
Main Author: | |
---|---|
Format: | Article |
Language: | English |
Published: |
EDP Sciences
2017-01-01
|
Series: | E3S Web of Conferences |
Online Access: | https://doi.org/10.1051/e3sconf/20171700021 |
id |
doaj-73d7d4ce8aba4536a801ffc71e2457f4 |
---|---|
record_format |
Article |
spelling |
doaj-73d7d4ce8aba4536a801ffc71e2457f42021-04-02T14:46:48ZengEDP SciencesE3S Web of Conferences2267-12422017-01-01170002110.1051/e3sconf/20171700021e3sconf_eko2017_00021An experimental study of the air humidification process using a membrane contactorEnglart Sebastian0Wrocław University of Science and Technology, Faculty of Environmental Engineering, Department of Air Conditioning, Heating, Gas Engineering and Air ProtectionThe article presents the results of the experimental examination of the effectiveness of air humidification using a membrane module. The construction of the membrane module and the measuring stand is also discussed. In order to assess the effectiveness of air humidification using the membrane module, the measurements of temperature and humidity at the membrane module’s inlet and outlet, air flow rate, water flow rate and water temperature were taken. Based on the measurements, the effectiveness coefficients, E, have been determined. The power demand for the solution under study has also been discussed.https://doi.org/10.1051/e3sconf/20171700021 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Englart Sebastian |
spellingShingle |
Englart Sebastian An experimental study of the air humidification process using a membrane contactor E3S Web of Conferences |
author_facet |
Englart Sebastian |
author_sort |
Englart Sebastian |
title |
An experimental study of the air humidification process using a membrane contactor |
title_short |
An experimental study of the air humidification process using a membrane contactor |
title_full |
An experimental study of the air humidification process using a membrane contactor |
title_fullStr |
An experimental study of the air humidification process using a membrane contactor |
title_full_unstemmed |
An experimental study of the air humidification process using a membrane contactor |
title_sort |
experimental study of the air humidification process using a membrane contactor |
publisher |
EDP Sciences |
series |
E3S Web of Conferences |
issn |
2267-1242 |
publishDate |
2017-01-01 |
description |
The article presents the results of the experimental examination of the effectiveness of air humidification using a membrane module. The construction of the membrane module and the measuring stand is also discussed. In order to assess the effectiveness of air humidification using the membrane module, the measurements of temperature and humidity at the membrane module’s inlet and outlet, air flow rate, water flow rate and water temperature were taken. Based on the measurements, the effectiveness coefficients, E, have been determined. The power demand for the solution under study has also been discussed. |
url |
https://doi.org/10.1051/e3sconf/20171700021 |
work_keys_str_mv |
AT englartsebastian anexperimentalstudyoftheairhumidificationprocessusingamembranecontactor AT englartsebastian experimentalstudyoftheairhumidificationprocessusingamembranecontactor |
_version_ |
1721561474032205824 |