LC–MS/MS quantitative analysis of phylloquinone, menaquinone-4 and menaquinone-7 in the human serum of a healthy population

A novel application of the liquid chromatography method combined with the triple quadrupole tandem mass spectrometry method was developed for the quantification of vitamin K1 and two forms of vitamin K2 (menaquinone-4, menaquinone-7) in human serum. Total chromatography time for each run was 9 min....

Full description

Bibliographic Details
Main Authors: Katerina Dunovska, Eva Klapkova, Bruno Sopko, Jana Cepova, Richard Prusa
Format: Article
Language:English
Published: PeerJ Inc. 2019-09-01
Series:PeerJ
Subjects:
Online Access:https://peerj.com/articles/7695.pdf
id doaj-73a41990b92949a4aedf85669624c964
record_format Article
spelling doaj-73a41990b92949a4aedf85669624c9642020-11-25T01:36:37ZengPeerJ Inc.PeerJ2167-83592019-09-017e769510.7717/peerj.7695LC–MS/MS quantitative analysis of phylloquinone, menaquinone-4 and menaquinone-7 in the human serum of a healthy populationKaterina DunovskaEva KlapkovaBruno SopkoJana CepovaRichard PrusaA novel application of the liquid chromatography method combined with the triple quadrupole tandem mass spectrometry method was developed for the quantification of vitamin K1 and two forms of vitamin K2 (menaquinone-4, menaquinone-7) in human serum. Total chromatography time for each run was 9 min. Time required for the sample pretreatment procedures was approximately 4 h. The coefficients of variation (CVs) of intra-assay were 10.4%, 3.2 % and 2.3% for vitamin K1 in three levels of quality control samples; were 14.3%, 3.2% and 6.7% for menaquinone-4; and were 11.1%, 6.0% and 7.0% for menaquinone-7. The inter-assay CVs were 12.8%, 11.3% and 7.4% for vitamin K1; were 15.2%, 9.2% and 8.7% for menaquinone-4; and were 13.2%,11.1% and 7.2% for menaquinone-7. No interference was found between K1, menaquinone-4 and menaquinone-7, nor any deuterated internal standards. This method was then used to determine reference values for Caucasian populations of central European origin. Samples were measured from 191 healthy volunteers (51.2 ± 16.2 years (mean ± SD)) and the values concerning K1 were 0.044–1.357 ng/mL for women and 0.030–1.214 ng/mL for men. The values for menaquinone-4 and menaquinone-7 did not exhibit any differences between women and men, and were 0.050–1.598 and 0.074–0.759 ng/mL, respectively.https://peerj.com/articles/7695.pdfPhylloquinoneMenaquinoneDeuterated internal standardLC–MS/MS
collection DOAJ
language English
format Article
sources DOAJ
author Katerina Dunovska
Eva Klapkova
Bruno Sopko
Jana Cepova
Richard Prusa
spellingShingle Katerina Dunovska
Eva Klapkova
Bruno Sopko
Jana Cepova
Richard Prusa
LC–MS/MS quantitative analysis of phylloquinone, menaquinone-4 and menaquinone-7 in the human serum of a healthy population
PeerJ
Phylloquinone
Menaquinone
Deuterated internal standard
LC–MS/MS
author_facet Katerina Dunovska
Eva Klapkova
Bruno Sopko
Jana Cepova
Richard Prusa
author_sort Katerina Dunovska
title LC–MS/MS quantitative analysis of phylloquinone, menaquinone-4 and menaquinone-7 in the human serum of a healthy population
title_short LC–MS/MS quantitative analysis of phylloquinone, menaquinone-4 and menaquinone-7 in the human serum of a healthy population
title_full LC–MS/MS quantitative analysis of phylloquinone, menaquinone-4 and menaquinone-7 in the human serum of a healthy population
title_fullStr LC–MS/MS quantitative analysis of phylloquinone, menaquinone-4 and menaquinone-7 in the human serum of a healthy population
title_full_unstemmed LC–MS/MS quantitative analysis of phylloquinone, menaquinone-4 and menaquinone-7 in the human serum of a healthy population
title_sort lc–ms/ms quantitative analysis of phylloquinone, menaquinone-4 and menaquinone-7 in the human serum of a healthy population
publisher PeerJ Inc.
series PeerJ
issn 2167-8359
publishDate 2019-09-01
description A novel application of the liquid chromatography method combined with the triple quadrupole tandem mass spectrometry method was developed for the quantification of vitamin K1 and two forms of vitamin K2 (menaquinone-4, menaquinone-7) in human serum. Total chromatography time for each run was 9 min. Time required for the sample pretreatment procedures was approximately 4 h. The coefficients of variation (CVs) of intra-assay were 10.4%, 3.2 % and 2.3% for vitamin K1 in three levels of quality control samples; were 14.3%, 3.2% and 6.7% for menaquinone-4; and were 11.1%, 6.0% and 7.0% for menaquinone-7. The inter-assay CVs were 12.8%, 11.3% and 7.4% for vitamin K1; were 15.2%, 9.2% and 8.7% for menaquinone-4; and were 13.2%,11.1% and 7.2% for menaquinone-7. No interference was found between K1, menaquinone-4 and menaquinone-7, nor any deuterated internal standards. This method was then used to determine reference values for Caucasian populations of central European origin. Samples were measured from 191 healthy volunteers (51.2 ± 16.2 years (mean ± SD)) and the values concerning K1 were 0.044–1.357 ng/mL for women and 0.030–1.214 ng/mL for men. The values for menaquinone-4 and menaquinone-7 did not exhibit any differences between women and men, and were 0.050–1.598 and 0.074–0.759 ng/mL, respectively.
topic Phylloquinone
Menaquinone
Deuterated internal standard
LC–MS/MS
url https://peerj.com/articles/7695.pdf
work_keys_str_mv AT katerinadunovska lcmsmsquantitativeanalysisofphylloquinonemenaquinone4andmenaquinone7inthehumanserumofahealthypopulation
AT evaklapkova lcmsmsquantitativeanalysisofphylloquinonemenaquinone4andmenaquinone7inthehumanserumofahealthypopulation
AT brunosopko lcmsmsquantitativeanalysisofphylloquinonemenaquinone4andmenaquinone7inthehumanserumofahealthypopulation
AT janacepova lcmsmsquantitativeanalysisofphylloquinonemenaquinone4andmenaquinone7inthehumanserumofahealthypopulation
AT richardprusa lcmsmsquantitativeanalysisofphylloquinonemenaquinone4andmenaquinone7inthehumanserumofahealthypopulation
_version_ 1725061980031549440