Natural ventilation and surface temperature distribution of piglet crate heated floors Ventilação natural e temperatura da superfície de pisos aquecidos em escamoteadores
This research had the objective of evaluating the influence of the natural ventilation on the surface temperature distribution of heated crates. The research used six crates from a farrowing room in a commercial swine production farm located in the state of São Paulo, Brazil. Three crates were heate...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Universidade Federal de Minas Gerais
2013-04-01
|
Series: | Arquivo Brasileiro de Medicina Veterinária e Zootecnia |
Subjects: | |
Online Access: | http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0102-09352013000200025 |
id |
doaj-73a1f52beb044b579f0e37e677faa205 |
---|---|
record_format |
Article |
spelling |
doaj-73a1f52beb044b579f0e37e677faa2052020-11-24T22:16:21ZengUniversidade Federal de Minas GeraisArquivo Brasileiro de Medicina Veterinária e Zootecnia0102-09351678-41622013-04-01652477484Natural ventilation and surface temperature distribution of piglet crate heated floors Ventilação natural e temperatura da superfície de pisos aquecidos em escamoteadoresA.S. MendesD.J. MouraI.A. NääsJ.R. BenderThis research had the objective of evaluating the influence of the natural ventilation on the surface temperature distribution of heated crates. The research used six crates from a farrowing room in a commercial swine production farm located in the state of São Paulo, Brazil. Three crates were heated using a heat mat while the other three had the environment heated by incandescent light bulbs (200W) fixed on the lateral wall. The surface temperature of the crate's floor (1.55x0.55m) was registered in 36 points, distributed in 18 quadrants (0.26x0.18m) using an infrared thermometer in three different conditions of the room's natural ventilation: opened, semi-opened, and closed lateral curtain. The isotherms and the temperature distribution of the floor heat were processed using the SURFER® (1995), and the statistical analysis was done using the MINITAB® (Statistical..., 2002). It was found that the room's natural ventilation had a significant influence on crate floor surface temperature distribution. The crate with a heat mat system provided higher temperatures and led to a more homogeneous surface temperature distribution.<br>O objetivo deste trabalho foi avaliar a influência da ventilação natural sobre a distribuição da temperatura na superfície de pisos aquecidos em escamoteadores. Foram avaliados seis escamoteadores da maternidade de uma granja de suínos localizada no estado de São Paulo. Dentre os escamoteadores avaliados, três deles usavam piso aquecido para o acondicionamento dos leitões, e os outros usavam lâmpadas incandescentes (200W), fixadas na parede lateral do interior do escamoteador. A temperatura da superfície do piso (1,55x0,55m) foi registrada medindo-se 36 pontos distribuídos em 18 quadrantes (0,26x0,18m), por meio de um termômetro infravermelho, em três diferentes condições de ventilação natural: com cortina lateral aberta, semiaberta e totalmente fechada. As isotermas e a distribuição da temperatura sobre o piso aquecido foram processadas usando-se o software SURFER®. Verificou-se que a ventilação natural teve efeito sobre a distribuição da temperatura da superfície do piso dos escamoteadores. O escamoteador aquecido com manta térmica forneceu temperaturas mais altas e distribuição mais homogênea na superfície de contato com os leitões.http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0102-09352013000200025suínosconforto térmicovelocidade do armaternidadethermal comfortair velocityfarrowingswine |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
A.S. Mendes D.J. Moura I.A. Nääs J.R. Bender |
spellingShingle |
A.S. Mendes D.J. Moura I.A. Nääs J.R. Bender Natural ventilation and surface temperature distribution of piglet crate heated floors Ventilação natural e temperatura da superfície de pisos aquecidos em escamoteadores Arquivo Brasileiro de Medicina Veterinária e Zootecnia suínos conforto térmico velocidade do ar maternidade thermal comfort air velocity farrowing swine |
author_facet |
A.S. Mendes D.J. Moura I.A. Nääs J.R. Bender |
author_sort |
A.S. Mendes |
title |
Natural ventilation and surface temperature distribution of piglet crate heated floors Ventilação natural e temperatura da superfície de pisos aquecidos em escamoteadores |
title_short |
Natural ventilation and surface temperature distribution of piglet crate heated floors Ventilação natural e temperatura da superfície de pisos aquecidos em escamoteadores |
title_full |
Natural ventilation and surface temperature distribution of piglet crate heated floors Ventilação natural e temperatura da superfície de pisos aquecidos em escamoteadores |
title_fullStr |
Natural ventilation and surface temperature distribution of piglet crate heated floors Ventilação natural e temperatura da superfície de pisos aquecidos em escamoteadores |
title_full_unstemmed |
Natural ventilation and surface temperature distribution of piglet crate heated floors Ventilação natural e temperatura da superfície de pisos aquecidos em escamoteadores |
title_sort |
natural ventilation and surface temperature distribution of piglet crate heated floors ventilação natural e temperatura da superfície de pisos aquecidos em escamoteadores |
publisher |
Universidade Federal de Minas Gerais |
series |
Arquivo Brasileiro de Medicina Veterinária e Zootecnia |
issn |
0102-0935 1678-4162 |
publishDate |
2013-04-01 |
description |
This research had the objective of evaluating the influence of the natural ventilation on the surface temperature distribution of heated crates. The research used six crates from a farrowing room in a commercial swine production farm located in the state of São Paulo, Brazil. Three crates were heated using a heat mat while the other three had the environment heated by incandescent light bulbs (200W) fixed on the lateral wall. The surface temperature of the crate's floor (1.55x0.55m) was registered in 36 points, distributed in 18 quadrants (0.26x0.18m) using an infrared thermometer in three different conditions of the room's natural ventilation: opened, semi-opened, and closed lateral curtain. The isotherms and the temperature distribution of the floor heat were processed using the SURFER® (1995), and the statistical analysis was done using the MINITAB® (Statistical..., 2002). It was found that the room's natural ventilation had a significant influence on crate floor surface temperature distribution. The crate with a heat mat system provided higher temperatures and led to a more homogeneous surface temperature distribution.<br>O objetivo deste trabalho foi avaliar a influência da ventilação natural sobre a distribuição da temperatura na superfície de pisos aquecidos em escamoteadores. Foram avaliados seis escamoteadores da maternidade de uma granja de suínos localizada no estado de São Paulo. Dentre os escamoteadores avaliados, três deles usavam piso aquecido para o acondicionamento dos leitões, e os outros usavam lâmpadas incandescentes (200W), fixadas na parede lateral do interior do escamoteador. A temperatura da superfície do piso (1,55x0,55m) foi registrada medindo-se 36 pontos distribuídos em 18 quadrantes (0,26x0,18m), por meio de um termômetro infravermelho, em três diferentes condições de ventilação natural: com cortina lateral aberta, semiaberta e totalmente fechada. As isotermas e a distribuição da temperatura sobre o piso aquecido foram processadas usando-se o software SURFER®. Verificou-se que a ventilação natural teve efeito sobre a distribuição da temperatura da superfície do piso dos escamoteadores. O escamoteador aquecido com manta térmica forneceu temperaturas mais altas e distribuição mais homogênea na superfície de contato com os leitões. |
topic |
suínos conforto térmico velocidade do ar maternidade thermal comfort air velocity farrowing swine |
url |
http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0102-09352013000200025 |
work_keys_str_mv |
AT asmendes naturalventilationandsurfacetemperaturedistributionofpigletcrateheatedfloorsventilacaonaturaletemperaturadasuperficiedepisosaquecidosemescamoteadores AT djmoura naturalventilationandsurfacetemperaturedistributionofpigletcrateheatedfloorsventilacaonaturaletemperaturadasuperficiedepisosaquecidosemescamoteadores AT ianaas naturalventilationandsurfacetemperaturedistributionofpigletcrateheatedfloorsventilacaonaturaletemperaturadasuperficiedepisosaquecidosemescamoteadores AT jrbender naturalventilationandsurfacetemperaturedistributionofpigletcrateheatedfloorsventilacaonaturaletemperaturadasuperficiedepisosaquecidosemescamoteadores |
_version_ |
1725790476470059008 |