X-ray Phase-Contrast Computed Tomography for Soft Tissue Imaging at the Imaging and Medical Beamline (IMBL) of the Australian Synchrotron
The Imaging and Medical Beamline (IMBL) is a superconducting multipole wiggler-based beamline at the 3 GeV Australian Synchrotron operated by the Australian Nuclear Science and Technology Organisation (ANSTO). The beamline delivers hard X-rays in the 25–120 keV energy range and offers the potential...
Main Authors: | Benedicta D. Arhatari, Andrew W. Stevenson, Brian Abbey, Yakov I. Nesterets, Anton Maksimenko, Christopher J. Hall, Darren Thompson, Sheridan C. Mayo, Tom Fiala, Harry M. Quiney, Seyedamir T. Taba, Sarah J. Lewis, Patrick C. Brennan, Matthew Dimmock, Daniel Häusermann, Timur E. Gureyev |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2021-04-01
|
Series: | Applied Sciences |
Subjects: | |
Online Access: | https://www.mdpi.com/2076-3417/11/9/4120 |
Similar Items
-
Comparing the effect of low and high emittance on synchrotron radiation and beamline design
by: A Gholampour Azhir, et al.
Published: (2017-08-01) -
Considerations in the design and operation of synchrotron radiation beamlines (including a discussion on the properties of synchrotron radiation
by: Neiser, Richard A.
Published: (2020) -
Transport Processes in Synchrotrons
by: Cole, Benjamin H. (Benjamin Holland)
Published: (1994) -
DAFNE-Light DXR1 Soft X-Ray Synchrotron Radiation Beamline: Characteristics and XAFS Applications
by: Antonella Balerna
Published: (2019-01-01) -
Using synchrotron imaging techniques to solve problems in neurosurgery
by: Kelly, Michael
Published: (2010)