Transcatheter aortic valve replacement (TAVR) leads to an increase in the subendocardial viability ratio assessed by pulse wave analysis.

BACKGROUND:Pulse wave analysis (PWA) is a useful tool for non-invasive assessment of central cardiac measures as subendocardial perfusion (Subendocardial Viability Ratio, SEVR) or contractility (dP/dtmax). The immediate influence of transcatheter aortic valve replacement (TAVR) on these indices has...

Full description

Bibliographic Details
Main Authors: Claudia Müller, Georg Goliasch, Stefan Schachinger, Stefan Kastl, Thomas Neunteufl, Georg Delle-Karth, Johannes Kastner, Mariann Gyöngyösi, Irene Lang, Michael Gottsauner-Wolf, Noemi Pavo
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2018-01-01
Series:PLoS ONE
Online Access:http://europepmc.org/articles/PMC6248990?pdf=render
id doaj-70842f23fce0415eaac0417a52d19881
record_format Article
spelling doaj-70842f23fce0415eaac0417a52d198812020-11-24T21:47:57ZengPublic Library of Science (PLoS)PLoS ONE1932-62032018-01-011311e020753710.1371/journal.pone.0207537Transcatheter aortic valve replacement (TAVR) leads to an increase in the subendocardial viability ratio assessed by pulse wave analysis.Claudia MüllerGeorg GoliaschStefan SchachingerStefan KastlThomas NeunteuflGeorg Delle-KarthJohannes KastnerMariann GyöngyösiIrene LangMichael Gottsauner-WolfNoemi PavoBACKGROUND:Pulse wave analysis (PWA) is a useful tool for non-invasive assessment of central cardiac measures as subendocardial perfusion (Subendocardial Viability Ratio, SEVR) or contractility (dP/dtmax). The immediate influence of transcatheter aortic valve replacement (TAVR) on these indices has not been investigated yet. METHODS:We prospectively enrolled 40 patients presenting with severe aortic stenosis receiving TAVR. Central pressure curves were derived from radial and carotid sites using PWA up to 2 days before and 7 days after TAVR. Parameters were compared between peripheral measurement sites. Changes in SEVR, dP/dtmax and in indices of vascular stiffness were assessed. Additionally, association of these variables with clinical outcome was evaluated during a 12-month follow-up. RESULTS:Central waveform parameters were comparable between measurement sites. SEVR, but not dP/dtmax, augmentation Index (AIx) or augmentation pressure height (AGPH) correlated significantly with disease severity reflected by peak transvalvular velocity and mean transvalvular pressure gradient over the aortic valve (Vmax, ΔPm) [r = -0.372,p = 0.029 for Vmax and r = -0.371,p = 0.021 for ΔPm]. Vmax decreased from 4.5m/s (IQR:4.1-5.0) to 2.2m/s (IQR:1.9-2.7), (p<0.001). This resulted in a significant increase in SEVR [135.3%(IQR:115.5-150.8) vs. 140.3%(IQR:123.0-172.5),p = 0.039] and dP/dtmax [666mmHg(IQR:489-891) vs. 927mmHg(IQR:693-1092),p<0.001], and a reduction in AIx [154.8%(IQR:138.3-171.0) vs. 133.5%(IQR:128.3-151.8),p<0.001] and AGPH [34.1%(IQR:26.8-39.0) vs. 25.0%(IQR 21.8-33.7),p = 0.002], confirming the beneficial effects of replacing the stenotic valve. No association of these parameters could be revealed with outcome. CONCLUSIONS:PWA is suitable for assessing coronary microcirculation and contractility mirrored by SEVR and maxdP/dt in the setting of aortic stenosis. PWA parameters attributed to vascular properties should be interpreted with caution.http://europepmc.org/articles/PMC6248990?pdf=render
collection DOAJ
language English
format Article
sources DOAJ
author Claudia Müller
Georg Goliasch
Stefan Schachinger
Stefan Kastl
Thomas Neunteufl
Georg Delle-Karth
Johannes Kastner
Mariann Gyöngyösi
Irene Lang
Michael Gottsauner-Wolf
Noemi Pavo
spellingShingle Claudia Müller
Georg Goliasch
Stefan Schachinger
Stefan Kastl
Thomas Neunteufl
Georg Delle-Karth
Johannes Kastner
Mariann Gyöngyösi
Irene Lang
Michael Gottsauner-Wolf
Noemi Pavo
Transcatheter aortic valve replacement (TAVR) leads to an increase in the subendocardial viability ratio assessed by pulse wave analysis.
PLoS ONE
author_facet Claudia Müller
Georg Goliasch
Stefan Schachinger
Stefan Kastl
Thomas Neunteufl
Georg Delle-Karth
Johannes Kastner
Mariann Gyöngyösi
Irene Lang
Michael Gottsauner-Wolf
Noemi Pavo
author_sort Claudia Müller
title Transcatheter aortic valve replacement (TAVR) leads to an increase in the subendocardial viability ratio assessed by pulse wave analysis.
title_short Transcatheter aortic valve replacement (TAVR) leads to an increase in the subendocardial viability ratio assessed by pulse wave analysis.
title_full Transcatheter aortic valve replacement (TAVR) leads to an increase in the subendocardial viability ratio assessed by pulse wave analysis.
title_fullStr Transcatheter aortic valve replacement (TAVR) leads to an increase in the subendocardial viability ratio assessed by pulse wave analysis.
title_full_unstemmed Transcatheter aortic valve replacement (TAVR) leads to an increase in the subendocardial viability ratio assessed by pulse wave analysis.
title_sort transcatheter aortic valve replacement (tavr) leads to an increase in the subendocardial viability ratio assessed by pulse wave analysis.
publisher Public Library of Science (PLoS)
series PLoS ONE
issn 1932-6203
publishDate 2018-01-01
description BACKGROUND:Pulse wave analysis (PWA) is a useful tool for non-invasive assessment of central cardiac measures as subendocardial perfusion (Subendocardial Viability Ratio, SEVR) or contractility (dP/dtmax). The immediate influence of transcatheter aortic valve replacement (TAVR) on these indices has not been investigated yet. METHODS:We prospectively enrolled 40 patients presenting with severe aortic stenosis receiving TAVR. Central pressure curves were derived from radial and carotid sites using PWA up to 2 days before and 7 days after TAVR. Parameters were compared between peripheral measurement sites. Changes in SEVR, dP/dtmax and in indices of vascular stiffness were assessed. Additionally, association of these variables with clinical outcome was evaluated during a 12-month follow-up. RESULTS:Central waveform parameters were comparable between measurement sites. SEVR, but not dP/dtmax, augmentation Index (AIx) or augmentation pressure height (AGPH) correlated significantly with disease severity reflected by peak transvalvular velocity and mean transvalvular pressure gradient over the aortic valve (Vmax, ΔPm) [r = -0.372,p = 0.029 for Vmax and r = -0.371,p = 0.021 for ΔPm]. Vmax decreased from 4.5m/s (IQR:4.1-5.0) to 2.2m/s (IQR:1.9-2.7), (p<0.001). This resulted in a significant increase in SEVR [135.3%(IQR:115.5-150.8) vs. 140.3%(IQR:123.0-172.5),p = 0.039] and dP/dtmax [666mmHg(IQR:489-891) vs. 927mmHg(IQR:693-1092),p<0.001], and a reduction in AIx [154.8%(IQR:138.3-171.0) vs. 133.5%(IQR:128.3-151.8),p<0.001] and AGPH [34.1%(IQR:26.8-39.0) vs. 25.0%(IQR 21.8-33.7),p = 0.002], confirming the beneficial effects of replacing the stenotic valve. No association of these parameters could be revealed with outcome. CONCLUSIONS:PWA is suitable for assessing coronary microcirculation and contractility mirrored by SEVR and maxdP/dt in the setting of aortic stenosis. PWA parameters attributed to vascular properties should be interpreted with caution.
url http://europepmc.org/articles/PMC6248990?pdf=render
work_keys_str_mv AT claudiamuller transcatheteraorticvalvereplacementtavrleadstoanincreaseinthesubendocardialviabilityratioassessedbypulsewaveanalysis
AT georggoliasch transcatheteraorticvalvereplacementtavrleadstoanincreaseinthesubendocardialviabilityratioassessedbypulsewaveanalysis
AT stefanschachinger transcatheteraorticvalvereplacementtavrleadstoanincreaseinthesubendocardialviabilityratioassessedbypulsewaveanalysis
AT stefankastl transcatheteraorticvalvereplacementtavrleadstoanincreaseinthesubendocardialviabilityratioassessedbypulsewaveanalysis
AT thomasneunteufl transcatheteraorticvalvereplacementtavrleadstoanincreaseinthesubendocardialviabilityratioassessedbypulsewaveanalysis
AT georgdellekarth transcatheteraorticvalvereplacementtavrleadstoanincreaseinthesubendocardialviabilityratioassessedbypulsewaveanalysis
AT johanneskastner transcatheteraorticvalvereplacementtavrleadstoanincreaseinthesubendocardialviabilityratioassessedbypulsewaveanalysis
AT marianngyongyosi transcatheteraorticvalvereplacementtavrleadstoanincreaseinthesubendocardialviabilityratioassessedbypulsewaveanalysis
AT irenelang transcatheteraorticvalvereplacementtavrleadstoanincreaseinthesubendocardialviabilityratioassessedbypulsewaveanalysis
AT michaelgottsaunerwolf transcatheteraorticvalvereplacementtavrleadstoanincreaseinthesubendocardialviabilityratioassessedbypulsewaveanalysis
AT noemipavo transcatheteraorticvalvereplacementtavrleadstoanincreaseinthesubendocardialviabilityratioassessedbypulsewaveanalysis
_version_ 1725894409691594752