A Wireless Sensor Network for Precise Volatile Organic Compound Monitoring

A variety of methods have been developed to monitor VOC concentration in hazardous sites. The methods range from calculation to measurement, point measuring to remote sensing. Some are suited for leak detection, others for estimation of the annual emission or both. None of the following available me...

Full description

Bibliographic Details
Main Authors: Gianfranco Manes, Giovanni Collodi, Rosanna Fusco, Leonardo Gelpi, Antonio Manes
Format: Article
Language:English
Published: SAGE Publishing 2012-04-01
Series:International Journal of Distributed Sensor Networks
Online Access:https://doi.org/10.1155/2012/820716
id doaj-7017106ea93f4047bc50b99ceb2555ea
record_format Article
spelling doaj-7017106ea93f4047bc50b99ceb2555ea2020-11-25T03:38:22ZengSAGE PublishingInternational Journal of Distributed Sensor Networks1550-14772012-04-01810.1155/2012/820716A Wireless Sensor Network for Precise Volatile Organic Compound MonitoringGianfranco Manes0Giovanni Collodi1Rosanna Fusco2Leonardo Gelpi3Antonio Manes4 University of Florence and The MIDRA Consortium, 50139 Florence, Italy University of Florence and The MIDRA Consortium, 50139 Florence, Italy Health, Safety, Environment and Quality Department, Eni S.p.A., 00144 Rome, Italy Health, Safety, Environment and Quality Department, Eni S.p.A., 00144 Rome, Italy Netsens s.r.l, Sesto Fiorentino, 50019 Florence, ItalyA variety of methods have been developed to monitor VOC concentration in hazardous sites. The methods range from calculation to measurement, point measuring to remote sensing. Some are suited for leak detection, others for estimation of the annual emission or both. None of the following available methods comes close to the ideal method. A distributed instrument providing precise monitoring of Volatile Organic Compound (VOC) concentration in a petrochemical plant is described; it consists of a Wireless Sensor Network (WSN) platform whose nodes are equipped with meteorological/climatic sensors and VOC detectors. Internet connectivity is provided in real time at a one-minute sampling rate, thus providing environmental authorities and plant management with an unprecedented tool for immediate warning in case of critical events. The paper describes the WSN platform, detailing various units (gateways, nodes, detectors) and shows the features of scalability and reconfigurability, with minimal intrusiveness or obtrusiveness. Environmental and process data are forwarded to a remote server and made available to the authenticated users through a rich user interface that provides data rendering in various formats and worldwide access to data. A survey of the VOC detector technologies involved is also provided.https://doi.org/10.1155/2012/820716
collection DOAJ
language English
format Article
sources DOAJ
author Gianfranco Manes
Giovanni Collodi
Rosanna Fusco
Leonardo Gelpi
Antonio Manes
spellingShingle Gianfranco Manes
Giovanni Collodi
Rosanna Fusco
Leonardo Gelpi
Antonio Manes
A Wireless Sensor Network for Precise Volatile Organic Compound Monitoring
International Journal of Distributed Sensor Networks
author_facet Gianfranco Manes
Giovanni Collodi
Rosanna Fusco
Leonardo Gelpi
Antonio Manes
author_sort Gianfranco Manes
title A Wireless Sensor Network for Precise Volatile Organic Compound Monitoring
title_short A Wireless Sensor Network for Precise Volatile Organic Compound Monitoring
title_full A Wireless Sensor Network for Precise Volatile Organic Compound Monitoring
title_fullStr A Wireless Sensor Network for Precise Volatile Organic Compound Monitoring
title_full_unstemmed A Wireless Sensor Network for Precise Volatile Organic Compound Monitoring
title_sort wireless sensor network for precise volatile organic compound monitoring
publisher SAGE Publishing
series International Journal of Distributed Sensor Networks
issn 1550-1477
publishDate 2012-04-01
description A variety of methods have been developed to monitor VOC concentration in hazardous sites. The methods range from calculation to measurement, point measuring to remote sensing. Some are suited for leak detection, others for estimation of the annual emission or both. None of the following available methods comes close to the ideal method. A distributed instrument providing precise monitoring of Volatile Organic Compound (VOC) concentration in a petrochemical plant is described; it consists of a Wireless Sensor Network (WSN) platform whose nodes are equipped with meteorological/climatic sensors and VOC detectors. Internet connectivity is provided in real time at a one-minute sampling rate, thus providing environmental authorities and plant management with an unprecedented tool for immediate warning in case of critical events. The paper describes the WSN platform, detailing various units (gateways, nodes, detectors) and shows the features of scalability and reconfigurability, with minimal intrusiveness or obtrusiveness. Environmental and process data are forwarded to a remote server and made available to the authenticated users through a rich user interface that provides data rendering in various formats and worldwide access to data. A survey of the VOC detector technologies involved is also provided.
url https://doi.org/10.1155/2012/820716
work_keys_str_mv AT gianfrancomanes awirelesssensornetworkforprecisevolatileorganiccompoundmonitoring
AT giovannicollodi awirelesssensornetworkforprecisevolatileorganiccompoundmonitoring
AT rosannafusco awirelesssensornetworkforprecisevolatileorganiccompoundmonitoring
AT leonardogelpi awirelesssensornetworkforprecisevolatileorganiccompoundmonitoring
AT antoniomanes awirelesssensornetworkforprecisevolatileorganiccompoundmonitoring
AT gianfrancomanes wirelesssensornetworkforprecisevolatileorganiccompoundmonitoring
AT giovannicollodi wirelesssensornetworkforprecisevolatileorganiccompoundmonitoring
AT rosannafusco wirelesssensornetworkforprecisevolatileorganiccompoundmonitoring
AT leonardogelpi wirelesssensornetworkforprecisevolatileorganiccompoundmonitoring
AT antoniomanes wirelesssensornetworkforprecisevolatileorganiccompoundmonitoring
_version_ 1724542513916674048