Digital hydraulic single-link trajectory tracking control through flow-based control

Recent advancement in controllability of digital hydraulic is similar to the performance of a proportional/servo hydraulic system, and several studies show that digital hydraulic will be an alternative for proportional/servo hydraulic. In this paper, tip point tracking of a single-link arm is taken...

Full description

Bibliographic Details
Main Authors: G Kalaiarassan, K Krishnamurthy
Format: Article
Language:English
Published: SAGE Publishing 2019-09-01
Series:Measurement + Control
Online Access:https://doi.org/10.1177/0020294019842889
id doaj-6ec524f623dd4e32bb70fba4f34eef21
record_format Article
spelling doaj-6ec524f623dd4e32bb70fba4f34eef212020-11-25T04:03:35ZengSAGE PublishingMeasurement + Control0020-29402019-09-015210.1177/0020294019842889Digital hydraulic single-link trajectory tracking control through flow-based controlG Kalaiarassan0K Krishnamurthy1Anna University, Chennai, IndiaKongu Engineering Collage (Autonomous, affiliated by anna university, chennai), Perundurai, Tamil Nadu, IndiaRecent advancement in controllability of digital hydraulic is similar to the performance of a proportional/servo hydraulic system, and several studies show that digital hydraulic will be an alternative for proportional/servo hydraulic. In this paper, tip point tracking of a single-link arm is taken as the subject of the study. Here, the single-link arm is controlled by a digital hydraulic system, which is established with parallel-connected on/off valves. In order to attain stepwise flow control, the pulse code modulation technique is used. By referring to the previous work, the control signal for the trajectory tracking is calculated by taking account of cylinder chamber pressure and velocity. But in this study, the required volume flow rate for trajectory tracing is taken into account for generating control signal. This approach improves the performance of the digital hydraulic system at lower velocity tracking and also reduces the computational complexity. The analysis is conducted with the proposed algorithm for 4-bit and 5-bit digital flow control units and tip point response of single link is presented. The results show that the 5-bit system has significantly better performance than the 4-bit system. In addition, the analysis is conducted with different stroke lengths such as 200, 100 and 50 mm for studying the behaviour of the system at lower velocity tracking. Better controllability is achieved at lower velocity tracking, and the results obtained with the proposed algorithm have nearly 2% tracking error.https://doi.org/10.1177/0020294019842889
collection DOAJ
language English
format Article
sources DOAJ
author G Kalaiarassan
K Krishnamurthy
spellingShingle G Kalaiarassan
K Krishnamurthy
Digital hydraulic single-link trajectory tracking control through flow-based control
Measurement + Control
author_facet G Kalaiarassan
K Krishnamurthy
author_sort G Kalaiarassan
title Digital hydraulic single-link trajectory tracking control through flow-based control
title_short Digital hydraulic single-link trajectory tracking control through flow-based control
title_full Digital hydraulic single-link trajectory tracking control through flow-based control
title_fullStr Digital hydraulic single-link trajectory tracking control through flow-based control
title_full_unstemmed Digital hydraulic single-link trajectory tracking control through flow-based control
title_sort digital hydraulic single-link trajectory tracking control through flow-based control
publisher SAGE Publishing
series Measurement + Control
issn 0020-2940
publishDate 2019-09-01
description Recent advancement in controllability of digital hydraulic is similar to the performance of a proportional/servo hydraulic system, and several studies show that digital hydraulic will be an alternative for proportional/servo hydraulic. In this paper, tip point tracking of a single-link arm is taken as the subject of the study. Here, the single-link arm is controlled by a digital hydraulic system, which is established with parallel-connected on/off valves. In order to attain stepwise flow control, the pulse code modulation technique is used. By referring to the previous work, the control signal for the trajectory tracking is calculated by taking account of cylinder chamber pressure and velocity. But in this study, the required volume flow rate for trajectory tracing is taken into account for generating control signal. This approach improves the performance of the digital hydraulic system at lower velocity tracking and also reduces the computational complexity. The analysis is conducted with the proposed algorithm for 4-bit and 5-bit digital flow control units and tip point response of single link is presented. The results show that the 5-bit system has significantly better performance than the 4-bit system. In addition, the analysis is conducted with different stroke lengths such as 200, 100 and 50 mm for studying the behaviour of the system at lower velocity tracking. Better controllability is achieved at lower velocity tracking, and the results obtained with the proposed algorithm have nearly 2% tracking error.
url https://doi.org/10.1177/0020294019842889
work_keys_str_mv AT gkalaiarassan digitalhydraulicsinglelinktrajectorytrackingcontrolthroughflowbasedcontrol
AT kkrishnamurthy digitalhydraulicsinglelinktrajectorytrackingcontrolthroughflowbasedcontrol
_version_ 1724439447667212288