Noise Risk Assessment in a Modern Olive Oil Mill
High levels of noise usually occur in olive oil mills because of the machines used to extract olive oil with a continuous plant. In Italy Law Decree 81/2008 defined the requirements for assessing and managing noise risk, identifying a number of procedures to be adopted at different noise levels to l...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
AIDIC Servizi S.r.l.
2017-06-01
|
Series: | Chemical Engineering Transactions |
Online Access: | https://www.cetjournal.it/index.php/cet/article/view/1288 |
id |
doaj-6ec3fe9808c24e5bbee1558134abce8e |
---|---|
record_format |
Article |
spelling |
doaj-6ec3fe9808c24e5bbee1558134abce8e2021-02-18T21:01:47ZengAIDIC Servizi S.r.l.Chemical Engineering Transactions2283-92162017-06-015810.3303/CET1758024Noise Risk Assessment in a Modern Olive Oil Mill M. ValloneG. MorelloP. CataniaHigh levels of noise usually occur in olive oil mills because of the machines used to extract olive oil with a continuous plant. In Italy Law Decree 81/2008 defined the requirements for assessing and managing noise risk, identifying a number of procedures to be adopted at different noise levels to limit workers exposure. This study aims at evaluating the equivalent and peak noise levels inside a modern oil mill plant area in Sicily, south Italy. Twenty measurement points were identified inside the oil mill plant area where the machines for olive oil extraction were located (about 200 m2). The instrument used for the measurements was a precision integrating portable sound level meter, class 1, model HD2110L by Delta OHM, Italy. The measured sound levels exceeded the limits allowed by the regulations in all the measurement points inside the working area; values exceeding the threshold limit of 80 dB(A) were recorded coming up to a maximum value of 93.3 dB(A) close to the hammer crusher. The operators involved are consequently obliged to wear the appropriate Personal Protective Equipment. https://www.cetjournal.it/index.php/cet/article/view/1288 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
M. Vallone G. Morello P. Catania |
spellingShingle |
M. Vallone G. Morello P. Catania Noise Risk Assessment in a Modern Olive Oil Mill Chemical Engineering Transactions |
author_facet |
M. Vallone G. Morello P. Catania |
author_sort |
M. Vallone |
title |
Noise Risk Assessment in a Modern Olive Oil Mill
|
title_short |
Noise Risk Assessment in a Modern Olive Oil Mill
|
title_full |
Noise Risk Assessment in a Modern Olive Oil Mill
|
title_fullStr |
Noise Risk Assessment in a Modern Olive Oil Mill
|
title_full_unstemmed |
Noise Risk Assessment in a Modern Olive Oil Mill
|
title_sort |
noise risk assessment in a modern olive oil mill |
publisher |
AIDIC Servizi S.r.l. |
series |
Chemical Engineering Transactions |
issn |
2283-9216 |
publishDate |
2017-06-01 |
description |
High levels of noise usually occur in olive oil mills because of the machines used to extract olive oil with a continuous plant. In Italy Law Decree 81/2008 defined the requirements for assessing and managing noise risk, identifying a number of procedures to be adopted at different noise levels to limit workers exposure. This study aims at evaluating the equivalent and peak noise levels inside a modern oil mill plant area in Sicily, south Italy. Twenty measurement points were identified inside the oil mill plant area where the machines for olive oil extraction were located (about 200 m2). The instrument used for the measurements was a precision integrating portable sound level meter, class 1, model HD2110L by Delta OHM, Italy. The measured sound levels exceeded the limits allowed by the regulations in all the measurement points inside the working area; values exceeding the threshold limit of 80 dB(A) were recorded coming up to a maximum value of 93.3 dB(A) close to the hammer crusher. The operators involved are consequently obliged to wear the appropriate Personal Protective Equipment.
|
url |
https://www.cetjournal.it/index.php/cet/article/view/1288 |
work_keys_str_mv |
AT mvallone noiseriskassessmentinamodernoliveoilmill AT gmorello noiseriskassessmentinamodernoliveoilmill AT pcatania noiseriskassessmentinamodernoliveoilmill |
_version_ |
1724262289667784704 |