Noise Risk Assessment in a Modern Olive Oil Mill

High levels of noise usually occur in olive oil mills because of the machines used to extract olive oil with a continuous plant. In Italy Law Decree 81/2008 defined the requirements for assessing and managing noise risk, identifying a number of procedures to be adopted at different noise levels to l...

Full description

Bibliographic Details
Main Authors: M. Vallone, G. Morello, P. Catania
Format: Article
Language:English
Published: AIDIC Servizi S.r.l. 2017-06-01
Series:Chemical Engineering Transactions
Online Access:https://www.cetjournal.it/index.php/cet/article/view/1288
id doaj-6ec3fe9808c24e5bbee1558134abce8e
record_format Article
spelling doaj-6ec3fe9808c24e5bbee1558134abce8e2021-02-18T21:01:47ZengAIDIC Servizi S.r.l.Chemical Engineering Transactions2283-92162017-06-015810.3303/CET1758024Noise Risk Assessment in a Modern Olive Oil Mill M. ValloneG. MorelloP. CataniaHigh levels of noise usually occur in olive oil mills because of the machines used to extract olive oil with a continuous plant. In Italy Law Decree 81/2008 defined the requirements for assessing and managing noise risk, identifying a number of procedures to be adopted at different noise levels to limit workers exposure. This study aims at evaluating the equivalent and peak noise levels inside a modern oil mill plant area in Sicily, south Italy. Twenty measurement points were identified inside the oil mill plant area where the machines for olive oil extraction were located (about 200 m2). The instrument used for the measurements was a precision integrating portable sound level meter, class 1, model HD2110L by Delta OHM, Italy. The measured sound levels exceeded the limits allowed by the regulations in all the measurement points inside the working area; values exceeding the threshold limit of 80 dB(A) were recorded coming up to a maximum value of 93.3 dB(A) close to the hammer crusher. The operators involved are consequently obliged to wear the appropriate Personal Protective Equipment. https://www.cetjournal.it/index.php/cet/article/view/1288
collection DOAJ
language English
format Article
sources DOAJ
author M. Vallone
G. Morello
P. Catania
spellingShingle M. Vallone
G. Morello
P. Catania
Noise Risk Assessment in a Modern Olive Oil Mill
Chemical Engineering Transactions
author_facet M. Vallone
G. Morello
P. Catania
author_sort M. Vallone
title Noise Risk Assessment in a Modern Olive Oil Mill
title_short Noise Risk Assessment in a Modern Olive Oil Mill
title_full Noise Risk Assessment in a Modern Olive Oil Mill
title_fullStr Noise Risk Assessment in a Modern Olive Oil Mill
title_full_unstemmed Noise Risk Assessment in a Modern Olive Oil Mill
title_sort noise risk assessment in a modern olive oil mill
publisher AIDIC Servizi S.r.l.
series Chemical Engineering Transactions
issn 2283-9216
publishDate 2017-06-01
description High levels of noise usually occur in olive oil mills because of the machines used to extract olive oil with a continuous plant. In Italy Law Decree 81/2008 defined the requirements for assessing and managing noise risk, identifying a number of procedures to be adopted at different noise levels to limit workers exposure. This study aims at evaluating the equivalent and peak noise levels inside a modern oil mill plant area in Sicily, south Italy. Twenty measurement points were identified inside the oil mill plant area where the machines for olive oil extraction were located (about 200 m2). The instrument used for the measurements was a precision integrating portable sound level meter, class 1, model HD2110L by Delta OHM, Italy. The measured sound levels exceeded the limits allowed by the regulations in all the measurement points inside the working area; values exceeding the threshold limit of 80 dB(A) were recorded coming up to a maximum value of 93.3 dB(A) close to the hammer crusher. The operators involved are consequently obliged to wear the appropriate Personal Protective Equipment.
url https://www.cetjournal.it/index.php/cet/article/view/1288
work_keys_str_mv AT mvallone noiseriskassessmentinamodernoliveoilmill
AT gmorello noiseriskassessmentinamodernoliveoilmill
AT pcatania noiseriskassessmentinamodernoliveoilmill
_version_ 1724262289667784704