Test-Retest Reliability and Concurrent Validity of a Single Tri-Axial Accelerometer-Based Gait Analysis in Older Adults with Normal Cognition.

We investigated the concurrent validity and test-retest reliability of spatio-temporal gait parameters measured with a single tri-axial accelerometer (TAA), determined the optimal number of steps required for obtaining acceptable levels of reliability, and compared the validity and reliability of th...

Full description

Bibliographic Details
Main Authors: Seonjeong Byun, Ji Won Han, Tae Hui Kim, Ki Woong Kim
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2016-01-01
Series:PLoS ONE
Online Access:http://europepmc.org/articles/PMC4948825?pdf=render
id doaj-6eb2a031b8a7438b9b911c98698a7f7d
record_format Article
spelling doaj-6eb2a031b8a7438b9b911c98698a7f7d2020-11-24T20:45:06ZengPublic Library of Science (PLoS)PLoS ONE1932-62032016-01-01117e015895610.1371/journal.pone.0158956Test-Retest Reliability and Concurrent Validity of a Single Tri-Axial Accelerometer-Based Gait Analysis in Older Adults with Normal Cognition.Seonjeong ByunJi Won HanTae Hui KimKi Woong KimWe investigated the concurrent validity and test-retest reliability of spatio-temporal gait parameters measured with a single tri-axial accelerometer (TAA), determined the optimal number of steps required for obtaining acceptable levels of reliability, and compared the validity and reliability of the estimated gait parameters across the three reference axes of the TAA.A total of 82 cognitively normal elderly participants walked around a 40-m long round walkway twice wearing a TAA at their center of body mass. Gait parameters such as cadence, gait velocity, step time, step length, step time variability, and step time asymmetry were estimated from the low pass-filtered signal of the TAA. The test-retest reliability and concurrent validity with the GAITRite® system were evaluated for the estimated gait parameters.Gait parameters using signals from the vertical axis showed excellent reliability for all gait parameters; the intraclass correlation coefficient (ICC) was 0.79-0.90. A minimum of 26 steps and 14 steps were needed to achieve excellent reliability in step time variability and step time asymmetry, respectively. A strong level of agreement was seen for the basic gait parameters between the TAA and GAITRiteⓇ (ICC = 0.91-0.96).The measurement of gait parameters of elderly individuals with normal cognition using a TAA placed on the body's center of mass was reliable and showed superiority over the GAITRiteⓇ with regard to gait variability and asymmetry. The TAA system was a valid tool for measuring basic gait parameters. Considering its wearability and low price, the TAA system may be a promising alternative to the pressure sensor walkway system for measuring gait parameters.http://europepmc.org/articles/PMC4948825?pdf=render
collection DOAJ
language English
format Article
sources DOAJ
author Seonjeong Byun
Ji Won Han
Tae Hui Kim
Ki Woong Kim
spellingShingle Seonjeong Byun
Ji Won Han
Tae Hui Kim
Ki Woong Kim
Test-Retest Reliability and Concurrent Validity of a Single Tri-Axial Accelerometer-Based Gait Analysis in Older Adults with Normal Cognition.
PLoS ONE
author_facet Seonjeong Byun
Ji Won Han
Tae Hui Kim
Ki Woong Kim
author_sort Seonjeong Byun
title Test-Retest Reliability and Concurrent Validity of a Single Tri-Axial Accelerometer-Based Gait Analysis in Older Adults with Normal Cognition.
title_short Test-Retest Reliability and Concurrent Validity of a Single Tri-Axial Accelerometer-Based Gait Analysis in Older Adults with Normal Cognition.
title_full Test-Retest Reliability and Concurrent Validity of a Single Tri-Axial Accelerometer-Based Gait Analysis in Older Adults with Normal Cognition.
title_fullStr Test-Retest Reliability and Concurrent Validity of a Single Tri-Axial Accelerometer-Based Gait Analysis in Older Adults with Normal Cognition.
title_full_unstemmed Test-Retest Reliability and Concurrent Validity of a Single Tri-Axial Accelerometer-Based Gait Analysis in Older Adults with Normal Cognition.
title_sort test-retest reliability and concurrent validity of a single tri-axial accelerometer-based gait analysis in older adults with normal cognition.
publisher Public Library of Science (PLoS)
series PLoS ONE
issn 1932-6203
publishDate 2016-01-01
description We investigated the concurrent validity and test-retest reliability of spatio-temporal gait parameters measured with a single tri-axial accelerometer (TAA), determined the optimal number of steps required for obtaining acceptable levels of reliability, and compared the validity and reliability of the estimated gait parameters across the three reference axes of the TAA.A total of 82 cognitively normal elderly participants walked around a 40-m long round walkway twice wearing a TAA at their center of body mass. Gait parameters such as cadence, gait velocity, step time, step length, step time variability, and step time asymmetry were estimated from the low pass-filtered signal of the TAA. The test-retest reliability and concurrent validity with the GAITRite® system were evaluated for the estimated gait parameters.Gait parameters using signals from the vertical axis showed excellent reliability for all gait parameters; the intraclass correlation coefficient (ICC) was 0.79-0.90. A minimum of 26 steps and 14 steps were needed to achieve excellent reliability in step time variability and step time asymmetry, respectively. A strong level of agreement was seen for the basic gait parameters between the TAA and GAITRiteⓇ (ICC = 0.91-0.96).The measurement of gait parameters of elderly individuals with normal cognition using a TAA placed on the body's center of mass was reliable and showed superiority over the GAITRiteⓇ with regard to gait variability and asymmetry. The TAA system was a valid tool for measuring basic gait parameters. Considering its wearability and low price, the TAA system may be a promising alternative to the pressure sensor walkway system for measuring gait parameters.
url http://europepmc.org/articles/PMC4948825?pdf=render
work_keys_str_mv AT seonjeongbyun testretestreliabilityandconcurrentvalidityofasingletriaxialaccelerometerbasedgaitanalysisinolderadultswithnormalcognition
AT jiwonhan testretestreliabilityandconcurrentvalidityofasingletriaxialaccelerometerbasedgaitanalysisinolderadultswithnormalcognition
AT taehuikim testretestreliabilityandconcurrentvalidityofasingletriaxialaccelerometerbasedgaitanalysisinolderadultswithnormalcognition
AT kiwoongkim testretestreliabilityandconcurrentvalidityofasingletriaxialaccelerometerbasedgaitanalysisinolderadultswithnormalcognition
_version_ 1716815454446551041