Analysis of new Gleeble tensile specimen design for hot stamping application

Hot tensile testing is useful to understand the material behavior at elevated temperatures. Hence it is of utmost importance that the test condition is accurate enough to derive stress-strain data in fully austenitic state and to ensure homogeneous deformation throughout the gauge length of the spec...

Full description

Bibliographic Details
Main Authors: Ganapathy Manikandan, Li Nan, Lin Jianguo, Abspoel Michael, Guido Hensen, Bhattacharjee Debashish
Format: Article
Language:English
Published: EDP Sciences 2015-01-01
Series:MATEC Web of Conferences
Online Access:http://dx.doi.org/10.1051/matecconf/20152105013
id doaj-6e933f62584b4d7e8a9d874e618075a3
record_format Article
spelling doaj-6e933f62584b4d7e8a9d874e618075a32021-03-02T10:24:47ZengEDP SciencesMATEC Web of Conferences2261-236X2015-01-01210501310.1051/matecconf/20152105013matecconf-icnft2015_05013Analysis of new Gleeble tensile specimen design for hot stamping applicationGanapathy Manikandan0Li Nan1Lin Jianguo2Abspoel Michael3Guido Hensen4Bhattacharjee Debashish5Mechanics of Materials, Department of Mechanical Engineering, Imperial College LondonMechanics of Materials, Department of Mechanical Engineering, Imperial College LondonMechanics of Materials, Department of Mechanical Engineering, Imperial College LondonResearch & Development, Tata SteelResearch & Development, Tata SteelResearch & Development, Tata SteelHot tensile testing is useful to understand the material behavior at elevated temperatures. Hence it is of utmost importance that the test condition is accurate enough to derive stress-strain data in fully austenitic state and to ensure homogeneous deformation throughout the gauge length of the specimen. But present limitation of standard Gleeble hot tensile sample geometry could not be used to achieve a uniform temperature distribution along the gauge section, thus creating errors of experimental data. In order to understand the effect of sample geometry on temperature gradient within the gauge section coupled electrical-thermal and thermo-mechanical finite element analysis has been carried out using Abaqus, with the use of viscoplastic damage constitutive equations presented by Li [1]. Based on the experimental study and numerical analysis, it was observed that the new sample geometry introduced by Abspoel [2], is able to achieve a better uniformity in temperature distribution along the gauge length; The temperature deviation along the gauge length within 25 ∘C during soaking and 5 ∘C after cooling and onset of deformation); also the strain deformation is found to be almost homogeneous.http://dx.doi.org/10.1051/matecconf/20152105013
collection DOAJ
language English
format Article
sources DOAJ
author Ganapathy Manikandan
Li Nan
Lin Jianguo
Abspoel Michael
Guido Hensen
Bhattacharjee Debashish
spellingShingle Ganapathy Manikandan
Li Nan
Lin Jianguo
Abspoel Michael
Guido Hensen
Bhattacharjee Debashish
Analysis of new Gleeble tensile specimen design for hot stamping application
MATEC Web of Conferences
author_facet Ganapathy Manikandan
Li Nan
Lin Jianguo
Abspoel Michael
Guido Hensen
Bhattacharjee Debashish
author_sort Ganapathy Manikandan
title Analysis of new Gleeble tensile specimen design for hot stamping application
title_short Analysis of new Gleeble tensile specimen design for hot stamping application
title_full Analysis of new Gleeble tensile specimen design for hot stamping application
title_fullStr Analysis of new Gleeble tensile specimen design for hot stamping application
title_full_unstemmed Analysis of new Gleeble tensile specimen design for hot stamping application
title_sort analysis of new gleeble tensile specimen design for hot stamping application
publisher EDP Sciences
series MATEC Web of Conferences
issn 2261-236X
publishDate 2015-01-01
description Hot tensile testing is useful to understand the material behavior at elevated temperatures. Hence it is of utmost importance that the test condition is accurate enough to derive stress-strain data in fully austenitic state and to ensure homogeneous deformation throughout the gauge length of the specimen. But present limitation of standard Gleeble hot tensile sample geometry could not be used to achieve a uniform temperature distribution along the gauge section, thus creating errors of experimental data. In order to understand the effect of sample geometry on temperature gradient within the gauge section coupled electrical-thermal and thermo-mechanical finite element analysis has been carried out using Abaqus, with the use of viscoplastic damage constitutive equations presented by Li [1]. Based on the experimental study and numerical analysis, it was observed that the new sample geometry introduced by Abspoel [2], is able to achieve a better uniformity in temperature distribution along the gauge length; The temperature deviation along the gauge length within 25 ∘C during soaking and 5 ∘C after cooling and onset of deformation); also the strain deformation is found to be almost homogeneous.
url http://dx.doi.org/10.1051/matecconf/20152105013
work_keys_str_mv AT ganapathymanikandan analysisofnewgleebletensilespecimendesignforhotstampingapplication
AT linan analysisofnewgleebletensilespecimendesignforhotstampingapplication
AT linjianguo analysisofnewgleebletensilespecimendesignforhotstampingapplication
AT abspoelmichael analysisofnewgleebletensilespecimendesignforhotstampingapplication
AT guidohensen analysisofnewgleebletensilespecimendesignforhotstampingapplication
AT bhattacharjeedebashish analysisofnewgleebletensilespecimendesignforhotstampingapplication
_version_ 1724236947962986496