Influence of Netted Collar on Scour depth around of Cubic Bridge Pier

Two major factors causing of scour around bridge piers are the down flow occurred in upstream part of the piers and separation of streamlines from piers called horseshoe  vortex. Installation of a collar on a pier will reduce the power of the down flow and horseshoe vortex. In this study, the effect...

Full description

Bibliographic Details
Main Authors: Ameneh Jalili, Mehdi Ghomeshi
Format: Article
Language:fas
Published: Shahid Chamran University of Ahvaz 2016-06-01
Series:علوم و مهندسی آبیاری
Subjects:
Online Access:http://jise.scu.ac.ir/article_12108_6a17db2b65e55c3a207489e2a7734fa4.pdf
id doaj-6e25e43d227d4fc6bc836983e0b94341
record_format Article
spelling doaj-6e25e43d227d4fc6bc836983e0b943412020-11-25T03:26:39ZfasShahid Chamran University of Ahvazعلوم و مهندسی آبیاری2588-59522588-59602016-06-01392152510.22055/jise.2016.1210812108Influence of Netted Collar on Scour depth around of Cubic Bridge PierAmeneh Jalili0Mehdi Ghomeshi1دانشجوی کارشناسی ارشد سازه های آبی، دانشکده مهندسی علوم آب، دانشگاه شهید چمران اهوازاستاد گروه سازه‌های آبی، دانشکده مهندسی علوم آب، دانشگاه شهید چمران اهوازTwo major factors causing of scour around bridge piers are the down flow occurred in upstream part of the piers and separation of streamlines from piers called horseshoe  vortex. Installation of a collar on a pier will reduce the power of the down flow and horseshoe vortex. In this study, the effects of placement of collar and netted collars on scour depth of cubic pier are investigated. The experimental flume was rectangular with the length of 7.3 meters, width of 0.56 m and a depth of 0.6 m. For this propose four collars included, one simple and three netted (with opening parts equal to 15percent, 30percent and 40percent), are tested under clear water condition. The experiments were performed in laboratory flume on Hydraulics Laboratory of Shahid Chamran University. The collars were installed in three levels equal to 0.5B, 0.25B and on the bed. The results were compared with the pier without the collar, and showed that the netted collar reduce the maximum scour depth between 34percent to 97percent in comparison with the case of no collar used. Also in low Froude Numbers, the netted collars showed better protection in comparison with the simple one.http://jise.scu.ac.ir/article_12108_6a17db2b65e55c3a207489e2a7734fa4.pdfscourcubic piercollarnetted collar
collection DOAJ
language fas
format Article
sources DOAJ
author Ameneh Jalili
Mehdi Ghomeshi
spellingShingle Ameneh Jalili
Mehdi Ghomeshi
Influence of Netted Collar on Scour depth around of Cubic Bridge Pier
علوم و مهندسی آبیاری
scour
cubic pier
collar
netted collar
author_facet Ameneh Jalili
Mehdi Ghomeshi
author_sort Ameneh Jalili
title Influence of Netted Collar on Scour depth around of Cubic Bridge Pier
title_short Influence of Netted Collar on Scour depth around of Cubic Bridge Pier
title_full Influence of Netted Collar on Scour depth around of Cubic Bridge Pier
title_fullStr Influence of Netted Collar on Scour depth around of Cubic Bridge Pier
title_full_unstemmed Influence of Netted Collar on Scour depth around of Cubic Bridge Pier
title_sort influence of netted collar on scour depth around of cubic bridge pier
publisher Shahid Chamran University of Ahvaz
series علوم و مهندسی آبیاری
issn 2588-5952
2588-5960
publishDate 2016-06-01
description Two major factors causing of scour around bridge piers are the down flow occurred in upstream part of the piers and separation of streamlines from piers called horseshoe  vortex. Installation of a collar on a pier will reduce the power of the down flow and horseshoe vortex. In this study, the effects of placement of collar and netted collars on scour depth of cubic pier are investigated. The experimental flume was rectangular with the length of 7.3 meters, width of 0.56 m and a depth of 0.6 m. For this propose four collars included, one simple and three netted (with opening parts equal to 15percent, 30percent and 40percent), are tested under clear water condition. The experiments were performed in laboratory flume on Hydraulics Laboratory of Shahid Chamran University. The collars were installed in three levels equal to 0.5B, 0.25B and on the bed. The results were compared with the pier without the collar, and showed that the netted collar reduce the maximum scour depth between 34percent to 97percent in comparison with the case of no collar used. Also in low Froude Numbers, the netted collars showed better protection in comparison with the simple one.
topic scour
cubic pier
collar
netted collar
url http://jise.scu.ac.ir/article_12108_6a17db2b65e55c3a207489e2a7734fa4.pdf
work_keys_str_mv AT amenehjalili influenceofnettedcollaronscourdeptharoundofcubicbridgepier
AT mehdighomeshi influenceofnettedcollaronscourdeptharoundofcubicbridgepier
_version_ 1724591573883158528