A Novel Method for Quantifying the Inhaled Dose of Air Pollutants Based on Heart Rate, Breathing Rate and Forced Vital Capacity.

To better understand the interaction of physical activity and air pollution exposure, it is important to quantify the change in ventilation rate incurred by activity. In this paper, we describe a method for estimating ventilation using easily-measured variables such as heart rate (HR), breathing rat...

Full description

Bibliographic Details
Main Authors: Roby Greenwald, Matthew J Hayat, Jerusha Barton, Anastasia Lopukhin
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2016-01-01
Series:PLoS ONE
Online Access:http://europepmc.org/articles/PMC4726691?pdf=render
id doaj-6ddefb4144c546c3808b6b878d25acec
record_format Article
spelling doaj-6ddefb4144c546c3808b6b878d25acec2020-11-25T01:28:20ZengPublic Library of Science (PLoS)PLoS ONE1932-62032016-01-01111e014757810.1371/journal.pone.0147578A Novel Method for Quantifying the Inhaled Dose of Air Pollutants Based on Heart Rate, Breathing Rate and Forced Vital Capacity.Roby GreenwaldMatthew J HayatJerusha BartonAnastasia LopukhinTo better understand the interaction of physical activity and air pollution exposure, it is important to quantify the change in ventilation rate incurred by activity. In this paper, we describe a method for estimating ventilation using easily-measured variables such as heart rate (HR), breathing rate (fB), and forced vital capacity (FVC). We recruited healthy adolescents to use a treadmill while we continuously measured HR, fB, and the tidal volume (VT) of each breath. Participants began at rest then walked and ran at increasing speed until HR was 160-180 beats per minute followed by a cool down period. The novel feature of this method is that minute ventilation ([Formula: see text]) was normalized by FVC. We used general linear mixed models with a random effect for subject and identified nine potential predictor variables that influence either [Formula: see text] or FVC. We assessed predictive performance with a five-fold cross-validation procedure. We used a brute force selection process to identify the best performing models based on cross-validation percent error, the Akaike Information Criterion and the p-value of parameter estimates. We found a two-predictor model including HR and fB to have the best predictive performance ([Formula: see text]/FVC = -4.247+0.0595HR+0.226fB, mean percent error = 8.1±29%); however, given the ubiquity of HR measurements, a one-predictor model including HR may also be useful ([Formula: see text]/FVC = -3.859+0.101HR, mean percent error = 11.3±36%).http://europepmc.org/articles/PMC4726691?pdf=render
collection DOAJ
language English
format Article
sources DOAJ
author Roby Greenwald
Matthew J Hayat
Jerusha Barton
Anastasia Lopukhin
spellingShingle Roby Greenwald
Matthew J Hayat
Jerusha Barton
Anastasia Lopukhin
A Novel Method for Quantifying the Inhaled Dose of Air Pollutants Based on Heart Rate, Breathing Rate and Forced Vital Capacity.
PLoS ONE
author_facet Roby Greenwald
Matthew J Hayat
Jerusha Barton
Anastasia Lopukhin
author_sort Roby Greenwald
title A Novel Method for Quantifying the Inhaled Dose of Air Pollutants Based on Heart Rate, Breathing Rate and Forced Vital Capacity.
title_short A Novel Method for Quantifying the Inhaled Dose of Air Pollutants Based on Heart Rate, Breathing Rate and Forced Vital Capacity.
title_full A Novel Method for Quantifying the Inhaled Dose of Air Pollutants Based on Heart Rate, Breathing Rate and Forced Vital Capacity.
title_fullStr A Novel Method for Quantifying the Inhaled Dose of Air Pollutants Based on Heart Rate, Breathing Rate and Forced Vital Capacity.
title_full_unstemmed A Novel Method for Quantifying the Inhaled Dose of Air Pollutants Based on Heart Rate, Breathing Rate and Forced Vital Capacity.
title_sort novel method for quantifying the inhaled dose of air pollutants based on heart rate, breathing rate and forced vital capacity.
publisher Public Library of Science (PLoS)
series PLoS ONE
issn 1932-6203
publishDate 2016-01-01
description To better understand the interaction of physical activity and air pollution exposure, it is important to quantify the change in ventilation rate incurred by activity. In this paper, we describe a method for estimating ventilation using easily-measured variables such as heart rate (HR), breathing rate (fB), and forced vital capacity (FVC). We recruited healthy adolescents to use a treadmill while we continuously measured HR, fB, and the tidal volume (VT) of each breath. Participants began at rest then walked and ran at increasing speed until HR was 160-180 beats per minute followed by a cool down period. The novel feature of this method is that minute ventilation ([Formula: see text]) was normalized by FVC. We used general linear mixed models with a random effect for subject and identified nine potential predictor variables that influence either [Formula: see text] or FVC. We assessed predictive performance with a five-fold cross-validation procedure. We used a brute force selection process to identify the best performing models based on cross-validation percent error, the Akaike Information Criterion and the p-value of parameter estimates. We found a two-predictor model including HR and fB to have the best predictive performance ([Formula: see text]/FVC = -4.247+0.0595HR+0.226fB, mean percent error = 8.1±29%); however, given the ubiquity of HR measurements, a one-predictor model including HR may also be useful ([Formula: see text]/FVC = -3.859+0.101HR, mean percent error = 11.3±36%).
url http://europepmc.org/articles/PMC4726691?pdf=render
work_keys_str_mv AT robygreenwald anovelmethodforquantifyingtheinhaleddoseofairpollutantsbasedonheartratebreathingrateandforcedvitalcapacity
AT matthewjhayat anovelmethodforquantifyingtheinhaleddoseofairpollutantsbasedonheartratebreathingrateandforcedvitalcapacity
AT jerushabarton anovelmethodforquantifyingtheinhaleddoseofairpollutantsbasedonheartratebreathingrateandforcedvitalcapacity
AT anastasialopukhin anovelmethodforquantifyingtheinhaleddoseofairpollutantsbasedonheartratebreathingrateandforcedvitalcapacity
AT robygreenwald novelmethodforquantifyingtheinhaleddoseofairpollutantsbasedonheartratebreathingrateandforcedvitalcapacity
AT matthewjhayat novelmethodforquantifyingtheinhaleddoseofairpollutantsbasedonheartratebreathingrateandforcedvitalcapacity
AT jerushabarton novelmethodforquantifyingtheinhaleddoseofairpollutantsbasedonheartratebreathingrateandforcedvitalcapacity
AT anastasialopukhin novelmethodforquantifyingtheinhaleddoseofairpollutantsbasedonheartratebreathingrateandforcedvitalcapacity
_version_ 1725102358350790656