The Energy Cost of Cold Thermal Discomfort in the Global South
The Global South, much of it in warm tropical latitudes, is expected to double its total energy demand by 2050. In addition to increased mean demand, greater demand for space cooling during external temperature peaks will exacerbate the strain on already fragile energy networks. Recent anecdotal evi...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2020-05-01
|
Series: | Buildings |
Subjects: | |
Online Access: | https://www.mdpi.com/2075-5309/10/5/93 |
id |
doaj-6dc1dedbd04f40fa9dcadd2176568596 |
---|---|
record_format |
Article |
spelling |
doaj-6dc1dedbd04f40fa9dcadd21765685962020-11-25T03:45:59ZengMDPI AGBuildings2075-53092020-05-0110939310.3390/buildings10050093The Energy Cost of Cold Thermal Discomfort in the Global SouthAbdulla N. Alnuaimi0Sukumar Natarajan1Department of Architecture & Civil Engineering, University of Bath, Bath BA2 7AY, UKDepartment of Architecture & Civil Engineering, University of Bath, Bath BA2 7AY, UKThe Global South, much of it in warm tropical latitudes, is expected to double its total energy demand by 2050. In addition to increased mean demand, greater demand for space cooling during external temperature peaks will exacerbate the strain on already fragile energy networks. Recent anecdotal evidence that a proportion of the increase in cooling demand is driven by cold—rather than warm—indoor thermal discomfort, suggests the imposition of an unnecessary cooling energy cost. Here, we investigate the impact of this cost on the expanding Global South using field data from four cities in India, Philippines, and Thailand. We observe that mean cold discomfort across the four cities is roughly 45 percentage points higher than warm discomfort, suggesting warmer indoor temperatures would not only lower overall discomfort but also reduce cooling energy demand. Computer simulations using a calibrated building model reveal that average savings of 10%/Kelvin and peak reductions of 3%–19%, would be feasible across the expected external temperature range in these cities. This suggests that more climatically appropriate indoor thermal comfort standards in the Global South would not only significantly counteract the expected rise in energy demand, but also produce more comfortable indoor conditions and reduce peak demand.https://www.mdpi.com/2075-5309/10/5/93building energythermal comfortglobal southcold thermal discomfortbuilding overcooling |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Abdulla N. Alnuaimi Sukumar Natarajan |
spellingShingle |
Abdulla N. Alnuaimi Sukumar Natarajan The Energy Cost of Cold Thermal Discomfort in the Global South Buildings building energy thermal comfort global south cold thermal discomfort building overcooling |
author_facet |
Abdulla N. Alnuaimi Sukumar Natarajan |
author_sort |
Abdulla N. Alnuaimi |
title |
The Energy Cost of Cold Thermal Discomfort in the Global South |
title_short |
The Energy Cost of Cold Thermal Discomfort in the Global South |
title_full |
The Energy Cost of Cold Thermal Discomfort in the Global South |
title_fullStr |
The Energy Cost of Cold Thermal Discomfort in the Global South |
title_full_unstemmed |
The Energy Cost of Cold Thermal Discomfort in the Global South |
title_sort |
energy cost of cold thermal discomfort in the global south |
publisher |
MDPI AG |
series |
Buildings |
issn |
2075-5309 |
publishDate |
2020-05-01 |
description |
The Global South, much of it in warm tropical latitudes, is expected to double its total energy demand by 2050. In addition to increased mean demand, greater demand for space cooling during external temperature peaks will exacerbate the strain on already fragile energy networks. Recent anecdotal evidence that a proportion of the increase in cooling demand is driven by cold—rather than warm—indoor thermal discomfort, suggests the imposition of an unnecessary cooling energy cost. Here, we investigate the impact of this cost on the expanding Global South using field data from four cities in India, Philippines, and Thailand. We observe that mean cold discomfort across the four cities is roughly 45 percentage points higher than warm discomfort, suggesting warmer indoor temperatures would not only lower overall discomfort but also reduce cooling energy demand. Computer simulations using a calibrated building model reveal that average savings of 10%/Kelvin and peak reductions of 3%–19%, would be feasible across the expected external temperature range in these cities. This suggests that more climatically appropriate indoor thermal comfort standards in the Global South would not only significantly counteract the expected rise in energy demand, but also produce more comfortable indoor conditions and reduce peak demand. |
topic |
building energy thermal comfort global south cold thermal discomfort building overcooling |
url |
https://www.mdpi.com/2075-5309/10/5/93 |
work_keys_str_mv |
AT abdullanalnuaimi theenergycostofcoldthermaldiscomfortintheglobalsouth AT sukumarnatarajan theenergycostofcoldthermaldiscomfortintheglobalsouth AT abdullanalnuaimi energycostofcoldthermaldiscomfortintheglobalsouth AT sukumarnatarajan energycostofcoldthermaldiscomfortintheglobalsouth |
_version_ |
1724508624878829568 |