Identificação dos espaços interespinhosos lombares por palpação e avaliados por radiografias Identificación de los espacios interespinosos lumbares por palpación y evaluados por radiografías Identification of the lumbar interspinous spaces by palpation and verified by X-rays

JUSTIFICATIVA E OBJETIVOS: A palpação foi demonstrada não ser muito precisa para identificar espaços interespinhosos lombares em anestesia neuroaxial. O objetivo deste estudo foi avaliar a precisão para determinar os espaços interespinhosos lombares pela palpação por anestesiologistas com o uso de r...

Full description

Bibliographic Details
Main Authors: Kei Tanaka, Shingo Irikoma, Sotaro Kokubo
Format: Article
Language:English
Published: Sociedade Brasileira de Anestesiologia 2013-06-01
Series:Revista Brasileira de Anestesiologia
Subjects:
Online Access:http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0034-70942013000300002
id doaj-6dc191128dcc4ce38e49807b3a238902
record_format Article
collection DOAJ
language English
format Article
sources DOAJ
author Kei Tanaka
Shingo Irikoma
Sotaro Kokubo
spellingShingle Kei Tanaka
Shingo Irikoma
Sotaro Kokubo
Identificação dos espaços interespinhosos lombares por palpação e avaliados por radiografias Identificación de los espacios interespinosos lumbares por palpación y evaluados por radiografías Identification of the lumbar interspinous spaces by palpation and verified by X-rays
Revista Brasileira de Anestesiologia
ANESTESIA, Obstétrica
CIRUGÍA, Cesárea
ANALGESIA, Parto
Palpación
Radiografía
ANESTESIA, Obstétrica
CIRURGIA, Cesárea
ANALGESIA, Parto
Palpação
Radiografia
Anesthesia, Obstetrical
Cesarean section
Analgesia, Epidural
Palpation
Radiography
author_facet Kei Tanaka
Shingo Irikoma
Sotaro Kokubo
author_sort Kei Tanaka
title Identificação dos espaços interespinhosos lombares por palpação e avaliados por radiografias Identificación de los espacios interespinosos lumbares por palpación y evaluados por radiografías Identification of the lumbar interspinous spaces by palpation and verified by X-rays
title_short Identificação dos espaços interespinhosos lombares por palpação e avaliados por radiografias Identificación de los espacios interespinosos lumbares por palpación y evaluados por radiografías Identification of the lumbar interspinous spaces by palpation and verified by X-rays
title_full Identificação dos espaços interespinhosos lombares por palpação e avaliados por radiografias Identificación de los espacios interespinosos lumbares por palpación y evaluados por radiografías Identification of the lumbar interspinous spaces by palpation and verified by X-rays
title_fullStr Identificação dos espaços interespinhosos lombares por palpação e avaliados por radiografias Identificación de los espacios interespinosos lumbares por palpación y evaluados por radiografías Identification of the lumbar interspinous spaces by palpation and verified by X-rays
title_full_unstemmed Identificação dos espaços interespinhosos lombares por palpação e avaliados por radiografias Identificación de los espacios interespinosos lumbares por palpación y evaluados por radiografías Identification of the lumbar interspinous spaces by palpation and verified by X-rays
title_sort identificação dos espaços interespinhosos lombares por palpação e avaliados por radiografias identificación de los espacios interespinosos lumbares por palpación y evaluados por radiografías identification of the lumbar interspinous spaces by palpation and verified by x-rays
publisher Sociedade Brasileira de Anestesiologia
series Revista Brasileira de Anestesiologia
issn 0034-7094
1806-907X
publishDate 2013-06-01
description JUSTIFICATIVA E OBJETIVOS: A palpação foi demonstrada não ser muito precisa para identificar espaços interespinhosos lombares em anestesia neuroaxial. O objetivo deste estudo foi avaliar a precisão para determinar os espaços interespinhosos lombares pela palpação por anestesiologistas com o uso de radiografias pós-operatórias em pacientes obstétricas. MÉTODOS: Revisamos os registros anestésicos e as radiografias abdominais pós-operatórias de cesarianas. Inserimos o cateter epidural para analgesia pós-operatória com dose única. Incluímos casos de anestesia combinada raqui-peridural e comparamos o nível interespinhoso registrado pelo anestesiologista e o nível de inserção do cateter peridural confirmado pela radiografia abdominal de cada caso. Também avaliamos os fatores (idade, peso, altura, Índice de Massa Corporal, idade gestacional e tipo de cirurgia [programada/emergência]) que levaram à identificação errônea do nível interespinhoso. RESULTADOS: Foram avaliadas 835 cesarianas de 967 feitas. Os níveis das punções documentados pelos anestesiologistas estavam de acordo com os níveis reais de inserção dos cateteres em 563 casos (67%). Quando os anestesiologistas objetivaram identificar o nível L2-3, descobrimos que a inserção do cateter foi em L1-2 em cinco casos (4,9%), dos quais nenhum apresentou qualquer déficit neurológico pós-operatório. Nenhuma das variáveis avaliadas estava significativamente associada à identificação errônea do nível interespinhoso pelos anestesiologistas. CONCLUSÃO: Houve uma discrepância entre o nível estimado pela palpação dos anestesiologistas e o nível real de inserção do cateter mostrado nas radiografias. Parece ser mais seguro escolher o nível interespinhoso L3-4, ou mais baixo, em raquianestesia.<br>JUSTIFICATIVA Y OBJETIVOS: Está comprobado que la palpación no es muy exacta para identificar los espacios interespinosos lumbares en la anestesia neuroaxial. El objetivo de este estudio, fue evaluar la precisión para determinar los espacios interespinosos lumbares a través de la palpación por anestesiólogos con el uso de radiografías postoperatorias de pacientes obstétricas. MÉTODOS: Revisamos los registros anestésicos y las radiografías abdominales postoperatorias de cesáreas. Insertamos el catéter epidural para la analgesia postoperatoria con una dosis única. Incluimos casos de anestesia combinada raqui-epidural y comparamos el nivel interespinoso registrado por el anestesiólogo y el nivel de inserción del catéter epidural confirmado por la radiografía abdominal de cada caso. También evaluamos los factores (edad, peso, altura, Índice de Masa Corporal, edad gestacional y tipo de cirugía [programada/emergencia]), que que levaram à identifi cação errônea do nível interespinhoso. RESULTADOS: Se evaluaron 835 cesáreas de las 967 que se hicieron. Los niveles de las punciones documentados por los anestesiólogos estaban a tono con los niveles reales de inserción de los catéteres en 563 casos (67%). Cuando los anestesiólogos quisieron identificar el nivel L2-3, descubrimos que la inserción del catéter fue en L1-2 en cinco casos (4,9%), de los cuales ninguno tuvo ningún déficit neurológico postoperatorio. Ninguna de las variables evaluadas estaba significativamente asociada con la identificación equivocada del nivel interespinoso por los anestesiólogos. CONCLUSIONES: Hubo una discrepancia entre el nivel estimado por la palpación de los anestesiólogos y el nivel real de inserción del catéter mostrado en las radiografías. Parece ser más seguro escoger el nivel interespinoso L3-4, o más bajo, en raquianestesia.<br>BACKGROUND AND OBJECTIVES: Palpation has been shown to be rather inaccurate at identifying lumbar interspinous spaces in neuraxial anesthesia. The aim of this study is to assess the accuracy of the determination of the lumbar interspinous spaces by anesthesiologist's palpation using post-operative X-rays in obstetric patients. METHODS: We reviewed the anesthetic record and the post-operative abdominal X-rays of the cesarean sections. We indwelled the epidural catheter for post-operative one-shot analgesia. We included combined spinal and epidural anesthesia cases and compared the interspinous level which the anesthesiologist recorded and the epidural catheter insertion level confirmed by abdominal X-ray for each case. We also evaluated the factors (age, body weight, height, Body Mass Index, gestational age, and the type of surgery [planned / emergency]) leading to misidentification of interspinous level. RESULTS: Nine hundred and sixty seven cesarean sections were performed and a total of 835 cases were evaluated. The levels of the puncture documented by the anesthesiologists were in agreement with the actual catheter insertion levels in 563 (67%) cases. When the anesthesiologists aimed at L2-3 level, we found the catheter insertion at L1-2 in 5 cases (4.9%), none of which had any post-operative neurological deficits. No variables evaluated were significantly associated with misidentification of interspinous level by the anesthesiologists. CONCLUSIONS: There was a discrepancy between the anesthesiologists' estimation by palpation and the actual catheter insertion level shown in X-rays. It seems to be safer to choose the interspinous level L3-4 or lower in spinal anesthesia.
topic ANESTESIA, Obstétrica
CIRUGÍA, Cesárea
ANALGESIA, Parto
Palpación
Radiografía
ANESTESIA, Obstétrica
CIRURGIA, Cesárea
ANALGESIA, Parto
Palpação
Radiografia
Anesthesia, Obstetrical
Cesarean section
Analgesia, Epidural
Palpation
Radiography
url http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0034-70942013000300002
work_keys_str_mv AT keitanaka identificacaodosespacosinterespinhososlombaresporpalpacaoeavaliadosporradiografiasidentificaciondelosespaciosinterespinososlumbaresporpalpacionyevaluadosporradiografiasidentificationofthelumbarinterspinousspacesbypalpationandverifiedbyxrays
AT shingoirikoma identificacaodosespacosinterespinhososlombaresporpalpacaoeavaliadosporradiografiasidentificaciondelosespaciosinterespinososlumbaresporpalpacionyevaluadosporradiografiasidentificationofthelumbarinterspinousspacesbypalpationandverifiedbyxrays
AT sotarokokubo identificacaodosespacosinterespinhososlombaresporpalpacaoeavaliadosporradiografiasidentificaciondelosespaciosinterespinososlumbaresporpalpacionyevaluadosporradiografiasidentificationofthelumbarinterspinousspacesbypalpationandverifiedbyxrays
_version_ 1725699984409493504
spelling doaj-6dc191128dcc4ce38e49807b3a2389022020-11-24T22:42:26ZengSociedade Brasileira de AnestesiologiaRevista Brasileira de Anestesiologia0034-70941806-907X2013-06-01633245248Identificação dos espaços interespinhosos lombares por palpação e avaliados por radiografias Identificación de los espacios interespinosos lumbares por palpación y evaluados por radiografías Identification of the lumbar interspinous spaces by palpation and verified by X-raysKei TanakaShingo IrikomaSotaro KokuboJUSTIFICATIVA E OBJETIVOS: A palpação foi demonstrada não ser muito precisa para identificar espaços interespinhosos lombares em anestesia neuroaxial. O objetivo deste estudo foi avaliar a precisão para determinar os espaços interespinhosos lombares pela palpação por anestesiologistas com o uso de radiografias pós-operatórias em pacientes obstétricas. MÉTODOS: Revisamos os registros anestésicos e as radiografias abdominais pós-operatórias de cesarianas. Inserimos o cateter epidural para analgesia pós-operatória com dose única. Incluímos casos de anestesia combinada raqui-peridural e comparamos o nível interespinhoso registrado pelo anestesiologista e o nível de inserção do cateter peridural confirmado pela radiografia abdominal de cada caso. Também avaliamos os fatores (idade, peso, altura, Índice de Massa Corporal, idade gestacional e tipo de cirurgia [programada/emergência]) que levaram à identificação errônea do nível interespinhoso. RESULTADOS: Foram avaliadas 835 cesarianas de 967 feitas. Os níveis das punções documentados pelos anestesiologistas estavam de acordo com os níveis reais de inserção dos cateteres em 563 casos (67%). Quando os anestesiologistas objetivaram identificar o nível L2-3, descobrimos que a inserção do cateter foi em L1-2 em cinco casos (4,9%), dos quais nenhum apresentou qualquer déficit neurológico pós-operatório. Nenhuma das variáveis avaliadas estava significativamente associada à identificação errônea do nível interespinhoso pelos anestesiologistas. CONCLUSÃO: Houve uma discrepância entre o nível estimado pela palpação dos anestesiologistas e o nível real de inserção do cateter mostrado nas radiografias. Parece ser mais seguro escolher o nível interespinhoso L3-4, ou mais baixo, em raquianestesia.<br>JUSTIFICATIVA Y OBJETIVOS: Está comprobado que la palpación no es muy exacta para identificar los espacios interespinosos lumbares en la anestesia neuroaxial. El objetivo de este estudio, fue evaluar la precisión para determinar los espacios interespinosos lumbares a través de la palpación por anestesiólogos con el uso de radiografías postoperatorias de pacientes obstétricas. MÉTODOS: Revisamos los registros anestésicos y las radiografías abdominales postoperatorias de cesáreas. Insertamos el catéter epidural para la analgesia postoperatoria con una dosis única. Incluimos casos de anestesia combinada raqui-epidural y comparamos el nivel interespinoso registrado por el anestesiólogo y el nivel de inserción del catéter epidural confirmado por la radiografía abdominal de cada caso. También evaluamos los factores (edad, peso, altura, Índice de Masa Corporal, edad gestacional y tipo de cirugía [programada/emergencia]), que que levaram à identifi cação errônea do nível interespinhoso. RESULTADOS: Se evaluaron 835 cesáreas de las 967 que se hicieron. Los niveles de las punciones documentados por los anestesiólogos estaban a tono con los niveles reales de inserción de los catéteres en 563 casos (67%). Cuando los anestesiólogos quisieron identificar el nivel L2-3, descubrimos que la inserción del catéter fue en L1-2 en cinco casos (4,9%), de los cuales ninguno tuvo ningún déficit neurológico postoperatorio. Ninguna de las variables evaluadas estaba significativamente asociada con la identificación equivocada del nivel interespinoso por los anestesiólogos. CONCLUSIONES: Hubo una discrepancia entre el nivel estimado por la palpación de los anestesiólogos y el nivel real de inserción del catéter mostrado en las radiografías. Parece ser más seguro escoger el nivel interespinoso L3-4, o más bajo, en raquianestesia.<br>BACKGROUND AND OBJECTIVES: Palpation has been shown to be rather inaccurate at identifying lumbar interspinous spaces in neuraxial anesthesia. The aim of this study is to assess the accuracy of the determination of the lumbar interspinous spaces by anesthesiologist's palpation using post-operative X-rays in obstetric patients. METHODS: We reviewed the anesthetic record and the post-operative abdominal X-rays of the cesarean sections. We indwelled the epidural catheter for post-operative one-shot analgesia. We included combined spinal and epidural anesthesia cases and compared the interspinous level which the anesthesiologist recorded and the epidural catheter insertion level confirmed by abdominal X-ray for each case. We also evaluated the factors (age, body weight, height, Body Mass Index, gestational age, and the type of surgery [planned / emergency]) leading to misidentification of interspinous level. RESULTS: Nine hundred and sixty seven cesarean sections were performed and a total of 835 cases were evaluated. The levels of the puncture documented by the anesthesiologists were in agreement with the actual catheter insertion levels in 563 (67%) cases. When the anesthesiologists aimed at L2-3 level, we found the catheter insertion at L1-2 in 5 cases (4.9%), none of which had any post-operative neurological deficits. No variables evaluated were significantly associated with misidentification of interspinous level by the anesthesiologists. CONCLUSIONS: There was a discrepancy between the anesthesiologists' estimation by palpation and the actual catheter insertion level shown in X-rays. It seems to be safer to choose the interspinous level L3-4 or lower in spinal anesthesia.http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0034-70942013000300002ANESTESIA, ObstétricaCIRUGÍA, CesáreaANALGESIA, PartoPalpaciónRadiografíaANESTESIA, ObstétricaCIRURGIA, CesáreaANALGESIA, PartoPalpaçãoRadiografiaAnesthesia, ObstetricalCesarean sectionAnalgesia, EpiduralPalpationRadiography