THERMAL CHANGES OBSERVED AT DRILLING SITE DURING BONE DRILLING Model study in bovine rib
The use of bone drill in the process of odontectomy and preparation of dental implant may increase temperature around drilling hole. As thermal changes are the critical precursor to physiological bone healing, increased of temperature over threshold must be minimized. The aim of this model study was...
Main Author: | |
---|---|
Format: | Article |
Language: | English |
Published: |
Universitas Gadjah Mada
2011-12-01
|
Series: | Jurnal Teknosains: Jurnal Ilmiah Sains dan Teknologi |
Online Access: | https://jurnal.ugm.ac.id/teknosains/article/view/3985 |
id |
doaj-6d496daa9de646258ffb487e145c95e6 |
---|---|
record_format |
Article |
spelling |
doaj-6d496daa9de646258ffb487e145c95e62020-11-24T21:56:35ZengUniversitas Gadjah MadaJurnal Teknosains: Jurnal Ilmiah Sains dan Teknologi2089-61312443-13112011-12-01111610.22146/teknosains.39853509THERMAL CHANGES OBSERVED AT DRILLING SITE DURING BONE DRILLING Model study in bovine ribDedy Kusuma0Department of Biomedical, Faculty of Dentistry Gadjah Mada University, Yogyakarta, IndonesiaThe use of bone drill in the process of odontectomy and preparation of dental implant may increase temperature around drilling hole. As thermal changes are the critical precursor to physiological bone healing, increased of temperature over threshold must be minimized. The aim of this model study was to compare the temperature changes that were generated during bone drilling with various speeds. Eighteen fresh bovine ribs were chosen due to the similarity of physical properties and dimension of human mandible. A constant drill load of 4.06N was applied throughout the drilling procedures via a drilling rig. Bovine ribs were drilled by using the same bur geometry (twist drill, 120 point angle) at low speed (8.750 rpm, 21.875 rpm, 35.000 rpm). The bone temperature changes generated by the drilling process were measured measured by K-type thermocouple. The speed of 8750 rpm produced a maximum temperature changes in both distance of 1 mm and 2 mm from drilling hole. Minimal temperature changes were recorded for the speed of 35.000 rpm. ANOVA test, showed the mean of thermal changes for each of speed at distance 1 and 2 mm from drilling hole. The clinical benefits of using speed below 35000 rpm need to be considered due to the potential risk of thermal damage.https://jurnal.ugm.ac.id/teknosains/article/view/3985 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Dedy Kusuma |
spellingShingle |
Dedy Kusuma THERMAL CHANGES OBSERVED AT DRILLING SITE DURING BONE DRILLING Model study in bovine rib Jurnal Teknosains: Jurnal Ilmiah Sains dan Teknologi |
author_facet |
Dedy Kusuma |
author_sort |
Dedy Kusuma |
title |
THERMAL CHANGES OBSERVED AT DRILLING SITE DURING BONE DRILLING Model study in bovine rib |
title_short |
THERMAL CHANGES OBSERVED AT DRILLING SITE DURING BONE DRILLING Model study in bovine rib |
title_full |
THERMAL CHANGES OBSERVED AT DRILLING SITE DURING BONE DRILLING Model study in bovine rib |
title_fullStr |
THERMAL CHANGES OBSERVED AT DRILLING SITE DURING BONE DRILLING Model study in bovine rib |
title_full_unstemmed |
THERMAL CHANGES OBSERVED AT DRILLING SITE DURING BONE DRILLING Model study in bovine rib |
title_sort |
thermal changes observed at drilling site during bone drilling model study in bovine rib |
publisher |
Universitas Gadjah Mada |
series |
Jurnal Teknosains: Jurnal Ilmiah Sains dan Teknologi |
issn |
2089-6131 2443-1311 |
publishDate |
2011-12-01 |
description |
The use of bone drill in the process of odontectomy and preparation of dental implant may increase temperature around drilling hole. As thermal changes are the critical precursor to physiological bone healing, increased of temperature over threshold must be minimized. The aim of this model study was to compare the temperature changes that were generated during bone drilling with various speeds. Eighteen fresh bovine ribs were chosen due to the similarity of physical properties and dimension of human mandible. A constant drill load of 4.06N was applied throughout the drilling procedures via a drilling rig. Bovine ribs were drilled by using the same bur geometry (twist drill, 120 point angle) at low speed (8.750 rpm, 21.875 rpm, 35.000 rpm). The bone temperature changes generated by the drilling process were measured measured by K-type thermocouple. The speed of 8750 rpm produced a maximum temperature changes in both distance of 1 mm and 2 mm from drilling hole. Minimal temperature changes were recorded for the speed of 35.000 rpm. ANOVA test, showed the mean of thermal changes for each of speed at distance 1 and 2 mm from drilling hole. The clinical benefits of using speed below 35000 rpm need to be considered due to the potential risk of thermal damage. |
url |
https://jurnal.ugm.ac.id/teknosains/article/view/3985 |
work_keys_str_mv |
AT dedykusuma thermalchangesobservedatdrillingsiteduringbonedrillingmodelstudyinbovinerib |
_version_ |
1725858336697483264 |