Comparing the Diagnostic Accuracy of Two Different Resolutions of Radiographs Captured with PSP Digital Intraoral Receptors in Detection of Secondary Caries (In Vitro)
Background and Aim: Considering the importance of detection of secondary caries, the adverse consequences of false positive and false negative diagnoses and the gap of information in the diagnostic efficacy of digital sensors in detection of secondary caries, this in vitro study sought to compare th...
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Islamic Azad University
2016-01-01
|
Series: | Journal of Research in Dental and Maxillofacial Sciences |
Subjects: | |
Online Access: | http://jrdms.dentaliau.ac.ir/browse.php?a_code=A-10-224-1&slc_lang=en&sid=1 |
id |
doaj-6cee7cf834fa4fee8e15d0e8d6eb1474 |
---|---|
record_format |
Article |
spelling |
doaj-6cee7cf834fa4fee8e15d0e8d6eb14742020-11-24T20:54:35ZengIslamic Azad UniversityJournal of Research in Dental and Maxillofacial Sciences2383-27542016-01-01114045Comparing the Diagnostic Accuracy of Two Different Resolutions of Radiographs Captured with PSP Digital Intraoral Receptors in Detection of Secondary Caries (In Vitro)S Mehralizade0S Nemati Anaraki1S Sakhdari2S Miraba3M Amiri Siavashani4S Bayat5 Assistant Professor, Oral and Maxillofacial Radiology Dept, Dental Branch of Tehran, Islamic Azad University, Tehran, Iran. Assistant Professor, Restorative Dept, Dental Branch of Tehran, Islamic Azad University, Tehran, Iran Assistant Professor, Oral and Maxillofacial Radiology Dept, Dental Branch of Tehran, Islamic Azad University, Tehran, Iran. Dental Branch of Tehran, Islamic Azad University, Tehran, Iran. ,Oral and Maxillofacial Radiology Dept, Dental Branch of Tehran, Islamic Azad University, Tehran, Iran Oral and Maxillofacial Radiology Dept, Dental Branch of Tehran, Islamic Azad University, Tehran, Iran. Background and Aim: Considering the importance of detection of secondary caries, the adverse consequences of false positive and false negative diagnoses and the gap of information in the diagnostic efficacy of digital sensors in detection of secondary caries, this in vitro study sought to compare the diagnostic efficacy of two different resolutions of radiographs obtained by photostimulable phosphor (PSP) plate intraoral sensors in detection of secondary caries in class II composite resin restorations using a standard technique. Methods and Materials: This diagnostic study was conducted on 40 extracted human second premolars. A classic class II cavity was prepared on one proximal surface of each tooth and restored with composite resin. Intraoral digital radiographs were obtained and saved in High and Super resolutions. Secondary caries were artificially created using a round bur mounted on a high-speed handpiece, and the teeth were radiographed again. Radiographs were saved with the mentioned two resolutions. All the radiographs were evaluated by three observers. Caries detection was classified using the yes/no dichotomous scale and data were statistically analyzed using kappa coefficient. Results: No significant differences were found in sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy of the two resolutions in caries detection (P>0.05). Conclusion: The High and Super resolutions of radiographs taken with digital intraoral PSP plates showed no significant differences in detection of artificially created secondary caries.http://jrdms.dentaliau.ac.ir/browse.php?a_code=A-10-224-1&slc_lang=en&sid=1Dental RadiographyDigital RadiographyDiagnosisDental CariesComposite resin |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
S Mehralizade S Nemati Anaraki S Sakhdari S Miraba M Amiri Siavashani S Bayat |
spellingShingle |
S Mehralizade S Nemati Anaraki S Sakhdari S Miraba M Amiri Siavashani S Bayat Comparing the Diagnostic Accuracy of Two Different Resolutions of Radiographs Captured with PSP Digital Intraoral Receptors in Detection of Secondary Caries (In Vitro) Journal of Research in Dental and Maxillofacial Sciences Dental Radiography Digital Radiography Diagnosis Dental Caries Composite resin |
author_facet |
S Mehralizade S Nemati Anaraki S Sakhdari S Miraba M Amiri Siavashani S Bayat |
author_sort |
S Mehralizade |
title |
Comparing the Diagnostic Accuracy of Two Different Resolutions of
Radiographs Captured with PSP Digital Intraoral Receptors in
Detection of Secondary Caries (In Vitro) |
title_short |
Comparing the Diagnostic Accuracy of Two Different Resolutions of
Radiographs Captured with PSP Digital Intraoral Receptors in
Detection of Secondary Caries (In Vitro) |
title_full |
Comparing the Diagnostic Accuracy of Two Different Resolutions of
Radiographs Captured with PSP Digital Intraoral Receptors in
Detection of Secondary Caries (In Vitro) |
title_fullStr |
Comparing the Diagnostic Accuracy of Two Different Resolutions of
Radiographs Captured with PSP Digital Intraoral Receptors in
Detection of Secondary Caries (In Vitro) |
title_full_unstemmed |
Comparing the Diagnostic Accuracy of Two Different Resolutions of
Radiographs Captured with PSP Digital Intraoral Receptors in
Detection of Secondary Caries (In Vitro) |
title_sort |
comparing the diagnostic accuracy of two different resolutions of
radiographs captured with psp digital intraoral receptors in
detection of secondary caries (in vitro) |
publisher |
Islamic Azad University |
series |
Journal of Research in Dental and Maxillofacial Sciences |
issn |
2383-2754 |
publishDate |
2016-01-01 |
description |
Background and Aim: Considering the importance of detection of secondary caries, the adverse consequences of false positive and false negative diagnoses and the gap of information in the diagnostic efficacy of digital sensors in detection of secondary caries, this in vitro study sought to compare the diagnostic efficacy of two different resolutions of radiographs obtained by photostimulable phosphor (PSP) plate intraoral sensors in detection of secondary caries in class II composite resin restorations using a standard technique.
Methods and Materials: This diagnostic study was conducted on 40 extracted human second premolars. A classic class II cavity was prepared on one proximal surface of each tooth and restored with composite resin. Intraoral digital radiographs were obtained and saved in High and Super resolutions. Secondary caries were artificially created using a round bur mounted on a high-speed handpiece, and the teeth were radiographed again. Radiographs were saved with the mentioned two resolutions. All the radiographs were evaluated by three observers. Caries detection was classified using the yes/no dichotomous scale and data were statistically analyzed using kappa coefficient.
Results: No significant differences were found in sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy of the two resolutions in caries detection (P>0.05).
Conclusion: The High and Super resolutions of radiographs taken with digital intraoral PSP plates showed no significant differences in detection of artificially created secondary caries. |
topic |
Dental Radiography Digital Radiography Diagnosis Dental Caries Composite resin |
url |
http://jrdms.dentaliau.ac.ir/browse.php?a_code=A-10-224-1&slc_lang=en&sid=1 |
work_keys_str_mv |
AT smehralizade comparingthediagnosticaccuracyoftwodifferentresolutionsofradiographscapturedwithpspdigitalintraoralreceptorsindetectionofsecondarycariesinvitro AT snematianaraki comparingthediagnosticaccuracyoftwodifferentresolutionsofradiographscapturedwithpspdigitalintraoralreceptorsindetectionofsecondarycariesinvitro AT ssakhdari comparingthediagnosticaccuracyoftwodifferentresolutionsofradiographscapturedwithpspdigitalintraoralreceptorsindetectionofsecondarycariesinvitro AT smiraba comparingthediagnosticaccuracyoftwodifferentresolutionsofradiographscapturedwithpspdigitalintraoralreceptorsindetectionofsecondarycariesinvitro AT mamirisiavashani comparingthediagnosticaccuracyoftwodifferentresolutionsofradiographscapturedwithpspdigitalintraoralreceptorsindetectionofsecondarycariesinvitro AT sbayat comparingthediagnosticaccuracyoftwodifferentresolutionsofradiographscapturedwithpspdigitalintraoralreceptorsindetectionofsecondarycariesinvitro |
_version_ |
1716794022505218048 |