Comparing the Diagnostic Accuracy of Two Different Resolutions of Radiographs Captured with PSP Digital Intraoral Receptors in Detection of Secondary Caries (In Vitro)

Background and Aim: Considering the importance of detection of secondary caries, the adverse consequences of false positive and false negative diagnoses and the gap of information in the diagnostic efficacy of digital sensors in detection of secondary caries, this in vitro study sought to compare th...

Full description

Bibliographic Details
Main Authors: S Mehralizade, S Nemati Anaraki, S Sakhdari, S Miraba, M Amiri Siavashani, S Bayat
Format: Article
Language:English
Published: Islamic Azad University 2016-01-01
Series:Journal of Research in Dental and Maxillofacial Sciences
Subjects:
Online Access:http://jrdms.dentaliau.ac.ir/browse.php?a_code=A-10-224-1&slc_lang=en&sid=1
id doaj-6cee7cf834fa4fee8e15d0e8d6eb1474
record_format Article
spelling doaj-6cee7cf834fa4fee8e15d0e8d6eb14742020-11-24T20:54:35ZengIslamic Azad UniversityJournal of Research in Dental and Maxillofacial Sciences2383-27542016-01-01114045Comparing the Diagnostic Accuracy of Two Different Resolutions of Radiographs Captured with PSP Digital Intraoral Receptors in Detection of Secondary Caries (In Vitro)S Mehralizade0S Nemati Anaraki1S Sakhdari2S Miraba3M Amiri Siavashani4S Bayat5 Assistant Professor, Oral and Maxillofacial Radiology Dept, Dental Branch of Tehran, Islamic Azad University, Tehran, Iran. Assistant Professor, Restorative Dept, Dental Branch of Tehran, Islamic Azad University, Tehran, Iran Assistant Professor, Oral and Maxillofacial Radiology Dept, Dental Branch of Tehran, Islamic Azad University, Tehran, Iran. Dental Branch of Tehran, Islamic Azad University, Tehran, Iran. ,Oral and Maxillofacial Radiology Dept, Dental Branch of Tehran, Islamic Azad University, Tehran, Iran Oral and Maxillofacial Radiology Dept, Dental Branch of Tehran, Islamic Azad University, Tehran, Iran. Background and Aim: Considering the importance of detection of secondary caries, the adverse consequences of false positive and false negative diagnoses and the gap of information in the diagnostic efficacy of digital sensors in detection of secondary caries, this in vitro study sought to compare the diagnostic efficacy of two different resolutions of radiographs obtained by photostimulable phosphor (PSP) plate intraoral sensors in detection of secondary caries in class II composite resin restorations using a standard technique.  Methods and Materials: This diagnostic study was conducted on 40 extracted human second premolars. A classic class II cavity was prepared on one proximal surface of each tooth and restored with composite resin. Intraoral digital radiographs were obtained and saved in High and Super resolutions. Secondary caries were artificially created using a round bur mounted on a high-speed handpiece, and the teeth were radiographed again. Radiographs were saved with the mentioned two resolutions. All the radiographs were evaluated by three observers. Caries detection was classified using the yes/no dichotomous scale and data were statistically analyzed using kappa coefficient.  Results: No significant differences were found in sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy of the two resolutions in caries detection (P>0.05). Conclusion: The High and Super resolutions of radiographs taken with digital intraoral PSP plates showed no significant differences in detection of artificially created secondary caries.http://jrdms.dentaliau.ac.ir/browse.php?a_code=A-10-224-1&slc_lang=en&sid=1Dental RadiographyDigital RadiographyDiagnosisDental CariesComposite resin
collection DOAJ
language English
format Article
sources DOAJ
author S Mehralizade
S Nemati Anaraki
S Sakhdari
S Miraba
M Amiri Siavashani
S Bayat
spellingShingle S Mehralizade
S Nemati Anaraki
S Sakhdari
S Miraba
M Amiri Siavashani
S Bayat
Comparing the Diagnostic Accuracy of Two Different Resolutions of Radiographs Captured with PSP Digital Intraoral Receptors in Detection of Secondary Caries (In Vitro)
Journal of Research in Dental and Maxillofacial Sciences
Dental Radiography
Digital Radiography
Diagnosis
Dental Caries
Composite resin
author_facet S Mehralizade
S Nemati Anaraki
S Sakhdari
S Miraba
M Amiri Siavashani
S Bayat
author_sort S Mehralizade
title Comparing the Diagnostic Accuracy of Two Different Resolutions of Radiographs Captured with PSP Digital Intraoral Receptors in Detection of Secondary Caries (In Vitro)
title_short Comparing the Diagnostic Accuracy of Two Different Resolutions of Radiographs Captured with PSP Digital Intraoral Receptors in Detection of Secondary Caries (In Vitro)
title_full Comparing the Diagnostic Accuracy of Two Different Resolutions of Radiographs Captured with PSP Digital Intraoral Receptors in Detection of Secondary Caries (In Vitro)
title_fullStr Comparing the Diagnostic Accuracy of Two Different Resolutions of Radiographs Captured with PSP Digital Intraoral Receptors in Detection of Secondary Caries (In Vitro)
title_full_unstemmed Comparing the Diagnostic Accuracy of Two Different Resolutions of Radiographs Captured with PSP Digital Intraoral Receptors in Detection of Secondary Caries (In Vitro)
title_sort comparing the diagnostic accuracy of two different resolutions of radiographs captured with psp digital intraoral receptors in detection of secondary caries (in vitro)
publisher Islamic Azad University
series Journal of Research in Dental and Maxillofacial Sciences
issn 2383-2754
publishDate 2016-01-01
description Background and Aim: Considering the importance of detection of secondary caries, the adverse consequences of false positive and false negative diagnoses and the gap of information in the diagnostic efficacy of digital sensors in detection of secondary caries, this in vitro study sought to compare the diagnostic efficacy of two different resolutions of radiographs obtained by photostimulable phosphor (PSP) plate intraoral sensors in detection of secondary caries in class II composite resin restorations using a standard technique.  Methods and Materials: This diagnostic study was conducted on 40 extracted human second premolars. A classic class II cavity was prepared on one proximal surface of each tooth and restored with composite resin. Intraoral digital radiographs were obtained and saved in High and Super resolutions. Secondary caries were artificially created using a round bur mounted on a high-speed handpiece, and the teeth were radiographed again. Radiographs were saved with the mentioned two resolutions. All the radiographs were evaluated by three observers. Caries detection was classified using the yes/no dichotomous scale and data were statistically analyzed using kappa coefficient.  Results: No significant differences were found in sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy of the two resolutions in caries detection (P>0.05). Conclusion: The High and Super resolutions of radiographs taken with digital intraoral PSP plates showed no significant differences in detection of artificially created secondary caries.
topic Dental Radiography
Digital Radiography
Diagnosis
Dental Caries
Composite resin
url http://jrdms.dentaliau.ac.ir/browse.php?a_code=A-10-224-1&slc_lang=en&sid=1
work_keys_str_mv AT smehralizade comparingthediagnosticaccuracyoftwodifferentresolutionsofradiographscapturedwithpspdigitalintraoralreceptorsindetectionofsecondarycariesinvitro
AT snematianaraki comparingthediagnosticaccuracyoftwodifferentresolutionsofradiographscapturedwithpspdigitalintraoralreceptorsindetectionofsecondarycariesinvitro
AT ssakhdari comparingthediagnosticaccuracyoftwodifferentresolutionsofradiographscapturedwithpspdigitalintraoralreceptorsindetectionofsecondarycariesinvitro
AT smiraba comparingthediagnosticaccuracyoftwodifferentresolutionsofradiographscapturedwithpspdigitalintraoralreceptorsindetectionofsecondarycariesinvitro
AT mamirisiavashani comparingthediagnosticaccuracyoftwodifferentresolutionsofradiographscapturedwithpspdigitalintraoralreceptorsindetectionofsecondarycariesinvitro
AT sbayat comparingthediagnosticaccuracyoftwodifferentresolutionsofradiographscapturedwithpspdigitalintraoralreceptorsindetectionofsecondarycariesinvitro
_version_ 1716794022505218048