Improvement of High-Power Three-Level Explosion-Proof Inverters Using Soft Switching Control Based on Optimized Power-Loss Algorithm

The high-power three-level explosion-proof inverters demand high thermal stability of power devices, and a set of theories and methods is needed to achieve an accurate power-loss calculation of power devices, to establish heat dissipation model, and ultimately to reduce the power loss to improve the...

Full description

Bibliographic Details
Main Authors: Shi-Zhou Xu, Feng-You He
Format: Article
Language:English
Published: Hindawi Limited 2015-01-01
Series:Journal of Electrical and Computer Engineering
Online Access:http://dx.doi.org/10.1155/2015/571209
id doaj-6b4566a05cc9483d9de9886e14fd706c
record_format Article
spelling doaj-6b4566a05cc9483d9de9886e14fd706c2021-07-02T07:01:17ZengHindawi LimitedJournal of Electrical and Computer Engineering2090-01472090-01552015-01-01201510.1155/2015/571209571209Improvement of High-Power Three-Level Explosion-Proof Inverters Using Soft Switching Control Based on Optimized Power-Loss AlgorithmShi-Zhou Xu0Feng-You He1Department of Information and Electrical Engineering, China University of Mining and Technology, No. 1 Daxue Road, Xuzhou, Jiangsu 221116, ChinaDepartment of Information and Electrical Engineering, China University of Mining and Technology, No. 1 Daxue Road, Xuzhou, Jiangsu 221116, ChinaThe high-power three-level explosion-proof inverters demand high thermal stability of power devices, and a set of theories and methods is needed to achieve an accurate power-loss calculation of power devices, to establish heat dissipation model, and ultimately to reduce the power loss to improve thermal stability of system. In this paper, the principle of neutral point clamped three-level (NPC3L) inverter is elaborated firstly, and a fourth-order RC equivalent circuit of IGBT is derived, on which basis the power-loss model of IGBT and the optimized maternal power-loss thermal model, using an optimized power-loss algorithm, are established. Secondly, in accordance with the optimized maternal power-loss thermal model, the generic formulas of power-loss calculation are deduced to calculate the power-loss modification values of NPC3L and soft switching three-level (S3L) inverters, which will be the thermal sources during thermal analysis for maternal power-loss thermal models. Finally, the experiment conducted on the 2.1 MW experimental platform shows that S3L inverter has the same excellent output characteristics with NPC3L inverter, reduces the power loss significantly by 213 W in each half-bridge, and decreases the temperature by 10°C, coinciding with the theoretical calculation, which verifies the accuracy of optimized power-loss algorithm and the effectiveness of the improvement.http://dx.doi.org/10.1155/2015/571209
collection DOAJ
language English
format Article
sources DOAJ
author Shi-Zhou Xu
Feng-You He
spellingShingle Shi-Zhou Xu
Feng-You He
Improvement of High-Power Three-Level Explosion-Proof Inverters Using Soft Switching Control Based on Optimized Power-Loss Algorithm
Journal of Electrical and Computer Engineering
author_facet Shi-Zhou Xu
Feng-You He
author_sort Shi-Zhou Xu
title Improvement of High-Power Three-Level Explosion-Proof Inverters Using Soft Switching Control Based on Optimized Power-Loss Algorithm
title_short Improvement of High-Power Three-Level Explosion-Proof Inverters Using Soft Switching Control Based on Optimized Power-Loss Algorithm
title_full Improvement of High-Power Three-Level Explosion-Proof Inverters Using Soft Switching Control Based on Optimized Power-Loss Algorithm
title_fullStr Improvement of High-Power Three-Level Explosion-Proof Inverters Using Soft Switching Control Based on Optimized Power-Loss Algorithm
title_full_unstemmed Improvement of High-Power Three-Level Explosion-Proof Inverters Using Soft Switching Control Based on Optimized Power-Loss Algorithm
title_sort improvement of high-power three-level explosion-proof inverters using soft switching control based on optimized power-loss algorithm
publisher Hindawi Limited
series Journal of Electrical and Computer Engineering
issn 2090-0147
2090-0155
publishDate 2015-01-01
description The high-power three-level explosion-proof inverters demand high thermal stability of power devices, and a set of theories and methods is needed to achieve an accurate power-loss calculation of power devices, to establish heat dissipation model, and ultimately to reduce the power loss to improve thermal stability of system. In this paper, the principle of neutral point clamped three-level (NPC3L) inverter is elaborated firstly, and a fourth-order RC equivalent circuit of IGBT is derived, on which basis the power-loss model of IGBT and the optimized maternal power-loss thermal model, using an optimized power-loss algorithm, are established. Secondly, in accordance with the optimized maternal power-loss thermal model, the generic formulas of power-loss calculation are deduced to calculate the power-loss modification values of NPC3L and soft switching three-level (S3L) inverters, which will be the thermal sources during thermal analysis for maternal power-loss thermal models. Finally, the experiment conducted on the 2.1 MW experimental platform shows that S3L inverter has the same excellent output characteristics with NPC3L inverter, reduces the power loss significantly by 213 W in each half-bridge, and decreases the temperature by 10°C, coinciding with the theoretical calculation, which verifies the accuracy of optimized power-loss algorithm and the effectiveness of the improvement.
url http://dx.doi.org/10.1155/2015/571209
work_keys_str_mv AT shizhouxu improvementofhighpowerthreelevelexplosionproofinvertersusingsoftswitchingcontrolbasedonoptimizedpowerlossalgorithm
AT fengyouhe improvementofhighpowerthreelevelexplosionproofinvertersusingsoftswitchingcontrolbasedonoptimizedpowerlossalgorithm
_version_ 1721336587665539072