Acoustic cardiac triggering: a practical solution for synchronization and gating of cardiovascular magnetic resonance at 7 Tesla

<p>Abstract</p> <p>Background</p> <p>To demonstrate the applicability of acoustic cardiac triggering (ACT) for imaging of the heart at ultrahigh magnetic fields (7.0 T) by comparing phonocardiogram, conventional vector electrocardiogram (ECG) and traditional pulse oxime...

Full description

Bibliographic Details
Main Authors: von Knobelsdorff-Brenkenhoff Florian, Dieringer Matthias, d'Orth Thibaut, Renz Wolfgang, Hezel Fabian, Frauenrath Tobias, Prothmann Marcel, Menger Jeanette, Niendorf Thoralf
Format: Article
Language:English
Published: BMC 2010-11-01
Series:Journal of Cardiovascular Magnetic Resonance
Online Access:http://www.jcmr-online.com/content/12/1/67
id doaj-6b03093249454067845e9429230a2f18
record_format Article
spelling doaj-6b03093249454067845e9429230a2f182020-11-25T02:28:17ZengBMCJournal of Cardiovascular Magnetic Resonance1097-66471532-429X2010-11-011216710.1186/1532-429X-12-67Acoustic cardiac triggering: a practical solution for synchronization and gating of cardiovascular magnetic resonance at 7 Teslavon Knobelsdorff-Brenkenhoff FlorianDieringer Matthiasd'Orth ThibautRenz WolfgangHezel FabianFrauenrath TobiasProthmann MarcelMenger JeanetteNiendorf Thoralf<p>Abstract</p> <p>Background</p> <p>To demonstrate the applicability of acoustic cardiac triggering (ACT) for imaging of the heart at ultrahigh magnetic fields (7.0 T) by comparing phonocardiogram, conventional vector electrocardiogram (ECG) and traditional pulse oximetry (POX) triggered 2D CINE acquisitions together with (i) a qualitative image quality analysis, (ii) an assessment of the left ventricular function parameter and (iii) an examination of trigger reliability and trigger detection variance derived from the signal waveforms.</p> <p>Results</p> <p>ECG was susceptible to severe distortions at 7.0 T. POX and ACT provided waveforms free of interferences from electromagnetic fields or from magneto-hydrodynamic effects. Frequent R-wave mis-registration occurred in ECG-triggered acquisitions with a failure rate of up to 30% resulting in cardiac motion induced artifacts. ACT and POX triggering produced images free of cardiac motion artefacts. ECG showed a severe jitter in the R-wave detection. POX also showed a trigger jitter of approximately Δt = 72 ms which is equivalent to two cardiac phases. ACT showed a jitter of approximately Δt = 5 ms only. ECG waveforms revealed a standard deviation for the cardiac trigger offset larger than that observed for ACT or POX waveforms.</p> <p>Image quality assessment showed that ACT substantially improved image quality as compared to ECG (image quality score at end-diastole: ECG = 1.7 ± 0.5, ACT = 2.4 ± 0.5, p = 0.04) while the comparison between ECG vs. POX gated acquisitions showed no significant differences in image quality (image quality score: ECG = 1.7 ± 0.5, POX = 2.0 ± 0.5, p = 0.34).</p> <p>Conclusions</p> <p>The applicability of acoustic triggering for cardiac CINE imaging at 7.0 T was demonstrated. ACT's trigger reliability and fidelity are superior to that of ECG and POX. ACT promises to be beneficial for cardiovascular magnetic resonance at ultra-high field strengths including 7.0 T.</p> http://www.jcmr-online.com/content/12/1/67
collection DOAJ
language English
format Article
sources DOAJ
author von Knobelsdorff-Brenkenhoff Florian
Dieringer Matthias
d'Orth Thibaut
Renz Wolfgang
Hezel Fabian
Frauenrath Tobias
Prothmann Marcel
Menger Jeanette
Niendorf Thoralf
spellingShingle von Knobelsdorff-Brenkenhoff Florian
Dieringer Matthias
d'Orth Thibaut
Renz Wolfgang
Hezel Fabian
Frauenrath Tobias
Prothmann Marcel
Menger Jeanette
Niendorf Thoralf
Acoustic cardiac triggering: a practical solution for synchronization and gating of cardiovascular magnetic resonance at 7 Tesla
Journal of Cardiovascular Magnetic Resonance
author_facet von Knobelsdorff-Brenkenhoff Florian
Dieringer Matthias
d'Orth Thibaut
Renz Wolfgang
Hezel Fabian
Frauenrath Tobias
Prothmann Marcel
Menger Jeanette
Niendorf Thoralf
author_sort von Knobelsdorff-Brenkenhoff Florian
title Acoustic cardiac triggering: a practical solution for synchronization and gating of cardiovascular magnetic resonance at 7 Tesla
title_short Acoustic cardiac triggering: a practical solution for synchronization and gating of cardiovascular magnetic resonance at 7 Tesla
title_full Acoustic cardiac triggering: a practical solution for synchronization and gating of cardiovascular magnetic resonance at 7 Tesla
title_fullStr Acoustic cardiac triggering: a practical solution for synchronization and gating of cardiovascular magnetic resonance at 7 Tesla
title_full_unstemmed Acoustic cardiac triggering: a practical solution for synchronization and gating of cardiovascular magnetic resonance at 7 Tesla
title_sort acoustic cardiac triggering: a practical solution for synchronization and gating of cardiovascular magnetic resonance at 7 tesla
publisher BMC
series Journal of Cardiovascular Magnetic Resonance
issn 1097-6647
1532-429X
publishDate 2010-11-01
description <p>Abstract</p> <p>Background</p> <p>To demonstrate the applicability of acoustic cardiac triggering (ACT) for imaging of the heart at ultrahigh magnetic fields (7.0 T) by comparing phonocardiogram, conventional vector electrocardiogram (ECG) and traditional pulse oximetry (POX) triggered 2D CINE acquisitions together with (i) a qualitative image quality analysis, (ii) an assessment of the left ventricular function parameter and (iii) an examination of trigger reliability and trigger detection variance derived from the signal waveforms.</p> <p>Results</p> <p>ECG was susceptible to severe distortions at 7.0 T. POX and ACT provided waveforms free of interferences from electromagnetic fields or from magneto-hydrodynamic effects. Frequent R-wave mis-registration occurred in ECG-triggered acquisitions with a failure rate of up to 30% resulting in cardiac motion induced artifacts. ACT and POX triggering produced images free of cardiac motion artefacts. ECG showed a severe jitter in the R-wave detection. POX also showed a trigger jitter of approximately Δt = 72 ms which is equivalent to two cardiac phases. ACT showed a jitter of approximately Δt = 5 ms only. ECG waveforms revealed a standard deviation for the cardiac trigger offset larger than that observed for ACT or POX waveforms.</p> <p>Image quality assessment showed that ACT substantially improved image quality as compared to ECG (image quality score at end-diastole: ECG = 1.7 ± 0.5, ACT = 2.4 ± 0.5, p = 0.04) while the comparison between ECG vs. POX gated acquisitions showed no significant differences in image quality (image quality score: ECG = 1.7 ± 0.5, POX = 2.0 ± 0.5, p = 0.34).</p> <p>Conclusions</p> <p>The applicability of acoustic triggering for cardiac CINE imaging at 7.0 T was demonstrated. ACT's trigger reliability and fidelity are superior to that of ECG and POX. ACT promises to be beneficial for cardiovascular magnetic resonance at ultra-high field strengths including 7.0 T.</p>
url http://www.jcmr-online.com/content/12/1/67
work_keys_str_mv AT vonknobelsdorffbrenkenhoffflorian acousticcardiactriggeringapracticalsolutionforsynchronizationandgatingofcardiovascularmagneticresonanceat7tesla
AT dieringermatthias acousticcardiactriggeringapracticalsolutionforsynchronizationandgatingofcardiovascularmagneticresonanceat7tesla
AT dorththibaut acousticcardiactriggeringapracticalsolutionforsynchronizationandgatingofcardiovascularmagneticresonanceat7tesla
AT renzwolfgang acousticcardiactriggeringapracticalsolutionforsynchronizationandgatingofcardiovascularmagneticresonanceat7tesla
AT hezelfabian acousticcardiactriggeringapracticalsolutionforsynchronizationandgatingofcardiovascularmagneticresonanceat7tesla
AT frauenrathtobias acousticcardiactriggeringapracticalsolutionforsynchronizationandgatingofcardiovascularmagneticresonanceat7tesla
AT prothmannmarcel acousticcardiactriggeringapracticalsolutionforsynchronizationandgatingofcardiovascularmagneticresonanceat7tesla
AT mengerjeanette acousticcardiactriggeringapracticalsolutionforsynchronizationandgatingofcardiovascularmagneticresonanceat7tesla
AT niendorfthoralf acousticcardiactriggeringapracticalsolutionforsynchronizationandgatingofcardiovascularmagneticresonanceat7tesla
_version_ 1724839355636252672