Pacemaker lead-related tricuspid stenosis successfully treated with percutaneous balloon valvuloplasty guided by 3D echocardiography

The most common etiology of tricuspid stenosis is rheumatic, and in most cases it is associated with valvular regurgitation. Interestingly, there have been reports of tricuspid stenosis without associated valvular regurgitation, mostly related to pacemaker leads. Percutaneous tricuspid valvuloplasty...

Full description

Bibliographic Details
Main Authors: Juan Carlos Rama-Merchan, Antonio Arribas-Jimenez, Javier Martin-Moreiras, Eulogio Garcia-Fernandez, Ignacio Cruz-Gonzalez
Format: Article
Language:English
Published: Elsevier 2014-11-01
Series:Revista Portuguesa de Cardiologia
Online Access:http://www.sciencedirect.com/science/article/pii/S0870255114002595
id doaj-6af441b2bd5d49928e3ba2e64624cf2b
record_format Article
spelling doaj-6af441b2bd5d49928e3ba2e64624cf2b2020-11-25T01:58:34ZengElsevierRevista Portuguesa de Cardiologia0870-25512014-11-013311739.e1739.e3Pacemaker lead-related tricuspid stenosis successfully treated with percutaneous balloon valvuloplasty guided by 3D echocardiographyJuan Carlos Rama-Merchan0Antonio Arribas-Jimenez1Javier Martin-Moreiras2Eulogio Garcia-Fernandez3Ignacio Cruz-Gonzalez4Servicio de Cardiología, Hospital Clínico Universitario de Salamanca, Salamanca, Spain; Corresponding author.Servicio de Cardiología, Hospital Clínico Universitario de Salamanca, Salamanca, SpainServicio de Cardiología, Hospital Clínico Universitario de Salamanca, Salamanca, SpainServicio de Cardiologia, Hospital Clínico San Carlos, Madrid, SpainServicio de Cardiología, Hospital Clínico Universitario de Salamanca, Salamanca, SpainThe most common etiology of tricuspid stenosis is rheumatic, and in most cases it is associated with valvular regurgitation. Interestingly, there have been reports of tricuspid stenosis without associated valvular regurgitation, mostly related to pacemaker leads. Percutaneous tricuspid valvuloplasty may be a therapeutic alternative to surgery in cases of pure tricuspid stenosis without other concomitant valvulopathies. We report the case of a 52-year-old woman with pacemaker lead-related tricuspid stenosis successfully treated with percutaneous valvuloplasty guided by 3D echocardiography. Resumo: A causa mais comum da estenose tricúspide é reumática, e na maioria dos casos está associada com insuficiência valvular. Curiosamente, tem havido relatos de estenose tricúspide sem insuficiência associada, sendo a maioria associados com electrocateteres de pacemaker. A plastia da valva tricúspide pode ser uma alternativa em casos de estenose valvular tricúspide pura, sem outras valvulopatias concomitantes. Relatamos o caso de uma mulher de 52 anos com estenose tricúspide associada a electrocateter de pacemaker tratada com sucesso com valvuloplastia percutânea guiada por ecocardiografia 3D. Keywords: Tricuspid stenosis, Pacemaker, Balloon valvuloplasty, 3D echocardiography, Palavras-chave: Estenose tricúspide, Pacemaker, Valvuloplastia com balão, Ecocardiografia 3Dhttp://www.sciencedirect.com/science/article/pii/S0870255114002595
collection DOAJ
language English
format Article
sources DOAJ
author Juan Carlos Rama-Merchan
Antonio Arribas-Jimenez
Javier Martin-Moreiras
Eulogio Garcia-Fernandez
Ignacio Cruz-Gonzalez
spellingShingle Juan Carlos Rama-Merchan
Antonio Arribas-Jimenez
Javier Martin-Moreiras
Eulogio Garcia-Fernandez
Ignacio Cruz-Gonzalez
Pacemaker lead-related tricuspid stenosis successfully treated with percutaneous balloon valvuloplasty guided by 3D echocardiography
Revista Portuguesa de Cardiologia
author_facet Juan Carlos Rama-Merchan
Antonio Arribas-Jimenez
Javier Martin-Moreiras
Eulogio Garcia-Fernandez
Ignacio Cruz-Gonzalez
author_sort Juan Carlos Rama-Merchan
title Pacemaker lead-related tricuspid stenosis successfully treated with percutaneous balloon valvuloplasty guided by 3D echocardiography
title_short Pacemaker lead-related tricuspid stenosis successfully treated with percutaneous balloon valvuloplasty guided by 3D echocardiography
title_full Pacemaker lead-related tricuspid stenosis successfully treated with percutaneous balloon valvuloplasty guided by 3D echocardiography
title_fullStr Pacemaker lead-related tricuspid stenosis successfully treated with percutaneous balloon valvuloplasty guided by 3D echocardiography
title_full_unstemmed Pacemaker lead-related tricuspid stenosis successfully treated with percutaneous balloon valvuloplasty guided by 3D echocardiography
title_sort pacemaker lead-related tricuspid stenosis successfully treated with percutaneous balloon valvuloplasty guided by 3d echocardiography
publisher Elsevier
series Revista Portuguesa de Cardiologia
issn 0870-2551
publishDate 2014-11-01
description The most common etiology of tricuspid stenosis is rheumatic, and in most cases it is associated with valvular regurgitation. Interestingly, there have been reports of tricuspid stenosis without associated valvular regurgitation, mostly related to pacemaker leads. Percutaneous tricuspid valvuloplasty may be a therapeutic alternative to surgery in cases of pure tricuspid stenosis without other concomitant valvulopathies. We report the case of a 52-year-old woman with pacemaker lead-related tricuspid stenosis successfully treated with percutaneous valvuloplasty guided by 3D echocardiography. Resumo: A causa mais comum da estenose tricúspide é reumática, e na maioria dos casos está associada com insuficiência valvular. Curiosamente, tem havido relatos de estenose tricúspide sem insuficiência associada, sendo a maioria associados com electrocateteres de pacemaker. A plastia da valva tricúspide pode ser uma alternativa em casos de estenose valvular tricúspide pura, sem outras valvulopatias concomitantes. Relatamos o caso de uma mulher de 52 anos com estenose tricúspide associada a electrocateter de pacemaker tratada com sucesso com valvuloplastia percutânea guiada por ecocardiografia 3D. Keywords: Tricuspid stenosis, Pacemaker, Balloon valvuloplasty, 3D echocardiography, Palavras-chave: Estenose tricúspide, Pacemaker, Valvuloplastia com balão, Ecocardiografia 3D
url http://www.sciencedirect.com/science/article/pii/S0870255114002595
work_keys_str_mv AT juancarlosramamerchan pacemakerleadrelatedtricuspidstenosissuccessfullytreatedwithpercutaneousballoonvalvuloplastyguidedby3dechocardiography
AT antonioarribasjimenez pacemakerleadrelatedtricuspidstenosissuccessfullytreatedwithpercutaneousballoonvalvuloplastyguidedby3dechocardiography
AT javiermartinmoreiras pacemakerleadrelatedtricuspidstenosissuccessfullytreatedwithpercutaneousballoonvalvuloplastyguidedby3dechocardiography
AT eulogiogarciafernandez pacemakerleadrelatedtricuspidstenosissuccessfullytreatedwithpercutaneousballoonvalvuloplastyguidedby3dechocardiography
AT ignaciocruzgonzalez pacemakerleadrelatedtricuspidstenosissuccessfullytreatedwithpercutaneousballoonvalvuloplastyguidedby3dechocardiography
_version_ 1724968840271495168