Experimental studies into the thermal-hydraulic performance of the VK-300 reactor based on a draft tube model

The paper presents an experimental study into the thermal-hydraulic performance of the VK-300 reactor based on a model of a single draft tube at a pressure of 3.4MPa, various flow rates and the model inlet relative enthalpies of –0.05 to 0.2. The experimental procedures include generation of a steam...

Full description

Bibliographic Details
Main Authors: N.P. Serdun, V.I. Ignatenko, G.S. Kotikov
Format: Article
Language:English
Published: National Research Nuclear University (MEPhI) 2015-12-01
Series:Nuclear Energy and Technology
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S2452303816000339
id doaj-6af2631a52c0499ca92bd85d01345b99
record_format Article
spelling doaj-6af2631a52c0499ca92bd85d01345b992020-11-25T01:40:10ZengNational Research Nuclear University (MEPhI)Nuclear Energy and Technology2452-30382015-12-011428829510.1016/j.nucet.2016.02.018Experimental studies into the thermal-hydraulic performance of the VK-300 reactor based on a draft tube modelN.P. SerdunV.I. IgnatenkoG.S. KotikovThe paper presents an experimental study into the thermal-hydraulic performance of the VK-300 reactor based on a model of a single draft tube at a pressure of 3.4MPa, various flow rates and the model inlet relative enthalpies of –0.05 to 0.2. The experimental procedures include generation of a steam-water mixture circulation with a preset flow rate and a relative enthalpy through the test section at a pressure of 3.3 to 3.4MPa, and measurement of thermal-hydraulic parameters within the circuit's representative upflow and downflow lengths of practical interest. There have been confirmed the designs used to support the reactor facility serviceability and the assumptions concerning the thermal-hydraulic performance of a natural circulation circuit used in the analysis thereof. It has been shown that, across the analyzed range of the relative enthalpy values, the draft tube has an annular-dispersed or an annular flow of the steam-water mixture, both providing for the significant separation of the steam-water mixture (Ksep=0.4) at the draft tube edges and in the mixing chamber. The perforation in the upper part of the draft tubes allows the separation coefficient to be increased at the first stage and creates more favorable conditions for the second-stage separation. The measured values of the void fraction in the mixing chamber and in the draft tube are in a satisfactory agreement with calculations based on Z.L. Miropolskiy's method and the RELAP code and may be used to verify the VK-300 thermal-hydraulic codes. It has been shown that steam may enter the ring slit that simulates the annular space and reach the reactor core inlet. Further investigations need to be conducted to study this effect for its guaranteed exclusion and for the development of emergency response procedures.http://www.sciencedirect.com/science/article/pii/S2452303816000339Nuclear reactorNatural circulationSeparation of steam-water mixtureSteam-water flow patternVoid fraction
collection DOAJ
language English
format Article
sources DOAJ
author N.P. Serdun
V.I. Ignatenko
G.S. Kotikov
spellingShingle N.P. Serdun
V.I. Ignatenko
G.S. Kotikov
Experimental studies into the thermal-hydraulic performance of the VK-300 reactor based on a draft tube model
Nuclear Energy and Technology
Nuclear reactor
Natural circulation
Separation of steam-water mixture
Steam-water flow pattern
Void fraction
author_facet N.P. Serdun
V.I. Ignatenko
G.S. Kotikov
author_sort N.P. Serdun
title Experimental studies into the thermal-hydraulic performance of the VK-300 reactor based on a draft tube model
title_short Experimental studies into the thermal-hydraulic performance of the VK-300 reactor based on a draft tube model
title_full Experimental studies into the thermal-hydraulic performance of the VK-300 reactor based on a draft tube model
title_fullStr Experimental studies into the thermal-hydraulic performance of the VK-300 reactor based on a draft tube model
title_full_unstemmed Experimental studies into the thermal-hydraulic performance of the VK-300 reactor based on a draft tube model
title_sort experimental studies into the thermal-hydraulic performance of the vk-300 reactor based on a draft tube model
publisher National Research Nuclear University (MEPhI)
series Nuclear Energy and Technology
issn 2452-3038
publishDate 2015-12-01
description The paper presents an experimental study into the thermal-hydraulic performance of the VK-300 reactor based on a model of a single draft tube at a pressure of 3.4MPa, various flow rates and the model inlet relative enthalpies of –0.05 to 0.2. The experimental procedures include generation of a steam-water mixture circulation with a preset flow rate and a relative enthalpy through the test section at a pressure of 3.3 to 3.4MPa, and measurement of thermal-hydraulic parameters within the circuit's representative upflow and downflow lengths of practical interest. There have been confirmed the designs used to support the reactor facility serviceability and the assumptions concerning the thermal-hydraulic performance of a natural circulation circuit used in the analysis thereof. It has been shown that, across the analyzed range of the relative enthalpy values, the draft tube has an annular-dispersed or an annular flow of the steam-water mixture, both providing for the significant separation of the steam-water mixture (Ksep=0.4) at the draft tube edges and in the mixing chamber. The perforation in the upper part of the draft tubes allows the separation coefficient to be increased at the first stage and creates more favorable conditions for the second-stage separation. The measured values of the void fraction in the mixing chamber and in the draft tube are in a satisfactory agreement with calculations based on Z.L. Miropolskiy's method and the RELAP code and may be used to verify the VK-300 thermal-hydraulic codes. It has been shown that steam may enter the ring slit that simulates the annular space and reach the reactor core inlet. Further investigations need to be conducted to study this effect for its guaranteed exclusion and for the development of emergency response procedures.
topic Nuclear reactor
Natural circulation
Separation of steam-water mixture
Steam-water flow pattern
Void fraction
url http://www.sciencedirect.com/science/article/pii/S2452303816000339
work_keys_str_mv AT npserdun experimentalstudiesintothethermalhydraulicperformanceofthevk300reactorbasedonadrafttubemodel
AT viignatenko experimentalstudiesintothethermalhydraulicperformanceofthevk300reactorbasedonadrafttubemodel
AT gskotikov experimentalstudiesintothethermalhydraulicperformanceofthevk300reactorbasedonadrafttubemodel
_version_ 1725046718729289728