APPROXIMATE CALCULATION OF ACTIVE RESISTANCE AND TEMPERATURE OF THE PULSE ELECTRIC ARC CHANNEL IN A HIGH-CURRENT DISCHARGE CIRCUIT OF A POWERFUL HIGH-VOLTAGE CAPACITOR ENERGY STORAGE

Purpose. To obtain calculation correlations for active resistance Rce and maximal temperature Tme of plasma channel of pulse electric arc in the air double-electrode system (DES) with metal (graphite) electrodes, and also practical approbation of the obtained correlations for Rce and Tme in the cond...

Full description

Bibliographic Details
Main Authors: M.I. Baranov, S. V. Rudakov
Format: Article
Language:English
Published: National Technical University "Kharkiv Polytechnic Institute" 2017-08-01
Series:Електротехніка і електромеханіка
Subjects:
Online Access:http://eie.khpi.edu.ua/article/view/2074-272X.2017.4.07/103772
Description
Summary:Purpose. To obtain calculation correlations for active resistance Rce and maximal temperature Tme of plasma channel of pulse electric arc in the air double-electrode system (DES) with metal (graphite) electrodes, and also practical approbation of the obtained correlations for Rce and Tme in the conditions of high-voltage laboratory on the powerful capacity energy storage (CES) of electric setting, intended for reproducing on the electric loading of protracted C- component of current of artificial lightning with the USA rationed on normative documents by amplitude-temporal parameters (ATP). Methodology. Electrophysics bases of high-voltage impulse technique, scientific and technical bases of development and creation of high-voltage high-current impulse electrical equipment, including powerful CES, and also measuring methods in discharge circuits of powerful high-voltage CES of pulse currents of millisecond temporal range. Results. On the basis of engineering approach the new results of approximate calculation of values of Rce and Tme are resulted in the plasma channel of pulse electric arc discharge in air DES of atmospheric pressure with metallic (graphite) electrodes. Practical approbation of results of calculation of values of Rce and Tme is executed as it applies to air DES, to connected in a discharge circuit of powerful high-voltage CES with protracted C- of component current of artificial lightning, characterized rationed ATP. It is shown that calculation of numeral value Rce approximately in 100 times exceeds the proper value of active resistance for the plasma channel of impulsive spark of electric discharge in air DES other things being equal, and a calculation of numeral value Tme well corresponds with the known thermodynamics information for classic electric arc in air DES of atmospheric pressure with graphite electrodes. Originality. New engineering approach is developed for the approximate calculation of values of Rce and Tme in electron-ion plasma of channel of pulse electric arc, arising in air DES of high-current discharge circuit of powerful high-voltage CES of proof-of-concept of electric setting of the technological setting. A formula is first obtained for the approximate calculation of equivalent active resistance of Rce of channel of pulse electric arc in air DES, remaining unchanging in the process of high-current discharge on RL- load of indicated CES. Practical value. Drawing on the got calculation results for the values of Rce and Tme in high-voltage impulse technique provides the rational choice of own electric parameters and construction elements of basic devices of powerful high-voltage CES of technological of electric setting, and also account of influence of electrical engineering descriptions of air DES on electromagnetic processes, taking place in the high-current discharge circuit of indicated CES with protracted C- of component current of artificial lightning.
ISSN:2074-272X
2309-3404