Numerical investigation of the large over-reading of Venturi flow rate in ARE of nuclear power plant
Venturi meter is frequently used in feed water flow control system in a nuclear power plant. Its accurate measurement plays a vital role in the safe operation of the plant. This paper firstly investigates the influence of the length of each section of pipeline, the throat inner diameter of Venturi a...
Main Authors: | Hong Wang, Zhimao Zhu, Miao Zhang, Jinlong Han |
---|---|
Format: | Article |
Language: | English |
Published: |
Elsevier
2021-01-01
|
Series: | Nuclear Engineering and Technology |
Subjects: | |
Online Access: | http://www.sciencedirect.com/science/article/pii/S1738573319310290 |