Numerical investigation of the large over-reading of Venturi flow rate in ARE of nuclear power plant

Venturi meter is frequently used in feed water flow control system in a nuclear power plant. Its accurate measurement plays a vital role in the safe operation of the plant. This paper firstly investigates the influence of the length of each section of pipeline, the throat inner diameter of Venturi a...

Full description

Bibliographic Details
Main Authors: Hong Wang, Zhimao Zhu, Miao Zhang, Jinlong Han
Format: Article
Language:English
Published: Elsevier 2021-01-01
Series:Nuclear Engineering and Technology
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S1738573319310290
id doaj-6a9749a9658d4e628e471bf4c2f1d0c0
record_format Article
spelling doaj-6a9749a9658d4e628e471bf4c2f1d0c02021-01-02T05:08:00ZengElsevierNuclear Engineering and Technology1738-57332021-01-015316978Numerical investigation of the large over-reading of Venturi flow rate in ARE of nuclear power plantHong Wang0Zhimao Zhu1Miao Zhang2Jinlong Han3Naval Architecture and Ocean Engineering College, Dalian Maritime University, Dalian, 116026, China; Corresponding author.Naval Architecture and Ocean Engineering College, Dalian Maritime University, Dalian, 116026, ChinaNaval Architecture and Ocean Engineering College, Dalian Maritime University, Dalian, 116026, ChinaLiaoning Hongyanhe Nuclear Power CO. LTD, Dalian, 116001, ChinaVenturi meter is frequently used in feed water flow control system in a nuclear power plant. Its accurate measurement plays a vital role in the safe operation of the plant. This paper firstly investigates the influence of the length of each section of pipeline, the throat inner diameter of Venturi and the flow characteristics in a single-phase flow on the accuracy of Venturi measurement by numerical calculation. Then the flow and the accuracy are discussed in a multi-phase flow. Numerical results show that the geometrical parameters and the characteristics of complex turbulent flow in the single-phase flow have little impact on the accuracy of Venturi flow rate measurement. In the multi-phase flow, the calculated flow rate of Venturi deviated from the actual flow rate and this deviation value is closely related to the amount of steam in the pipeline and increases sharply with the increase of the amount of steam. The over-reading of Venturi flow rate is present.http://www.sciencedirect.com/science/article/pii/S1738573319310290Venturi flow rateOver-readingFlow characteristicsMulti-phase flow
collection DOAJ
language English
format Article
sources DOAJ
author Hong Wang
Zhimao Zhu
Miao Zhang
Jinlong Han
spellingShingle Hong Wang
Zhimao Zhu
Miao Zhang
Jinlong Han
Numerical investigation of the large over-reading of Venturi flow rate in ARE of nuclear power plant
Nuclear Engineering and Technology
Venturi flow rate
Over-reading
Flow characteristics
Multi-phase flow
author_facet Hong Wang
Zhimao Zhu
Miao Zhang
Jinlong Han
author_sort Hong Wang
title Numerical investigation of the large over-reading of Venturi flow rate in ARE of nuclear power plant
title_short Numerical investigation of the large over-reading of Venturi flow rate in ARE of nuclear power plant
title_full Numerical investigation of the large over-reading of Venturi flow rate in ARE of nuclear power plant
title_fullStr Numerical investigation of the large over-reading of Venturi flow rate in ARE of nuclear power plant
title_full_unstemmed Numerical investigation of the large over-reading of Venturi flow rate in ARE of nuclear power plant
title_sort numerical investigation of the large over-reading of venturi flow rate in are of nuclear power plant
publisher Elsevier
series Nuclear Engineering and Technology
issn 1738-5733
publishDate 2021-01-01
description Venturi meter is frequently used in feed water flow control system in a nuclear power plant. Its accurate measurement plays a vital role in the safe operation of the plant. This paper firstly investigates the influence of the length of each section of pipeline, the throat inner diameter of Venturi and the flow characteristics in a single-phase flow on the accuracy of Venturi measurement by numerical calculation. Then the flow and the accuracy are discussed in a multi-phase flow. Numerical results show that the geometrical parameters and the characteristics of complex turbulent flow in the single-phase flow have little impact on the accuracy of Venturi flow rate measurement. In the multi-phase flow, the calculated flow rate of Venturi deviated from the actual flow rate and this deviation value is closely related to the amount of steam in the pipeline and increases sharply with the increase of the amount of steam. The over-reading of Venturi flow rate is present.
topic Venturi flow rate
Over-reading
Flow characteristics
Multi-phase flow
url http://www.sciencedirect.com/science/article/pii/S1738573319310290
work_keys_str_mv AT hongwang numericalinvestigationofthelargeoverreadingofventuriflowrateinareofnuclearpowerplant
AT zhimaozhu numericalinvestigationofthelargeoverreadingofventuriflowrateinareofnuclearpowerplant
AT miaozhang numericalinvestigationofthelargeoverreadingofventuriflowrateinareofnuclearpowerplant
AT jinlonghan numericalinvestigationofthelargeoverreadingofventuriflowrateinareofnuclearpowerplant
_version_ 1724359782897287168