Evaluation of indoor temperature for various building envelopes damaged
The purpose of this paper is to represent inner air temperature calculation algorithm provided that interior space is formed by several building envelopes which transmit thermal losses. The chosen external wall includes an area with damaged structural layers. We examine one-dimensional thermal trans...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
EDP Sciences
2018-01-01
|
Series: | E3S Web of Conferences |
Online Access: | https://doi.org/10.1051/e3sconf/20183201019 |
id |
doaj-6a844c2f967e410a9b063bce52f9f722 |
---|---|
record_format |
Article |
spelling |
doaj-6a844c2f967e410a9b063bce52f9f7222021-02-02T01:19:18ZengEDP SciencesE3S Web of Conferences2267-12422018-01-01320101910.1051/e3sconf/20183201019e3sconf_eenviro2018_01019Evaluation of indoor temperature for various building envelopes damagedPetrenko ViktorDikarev KostiantynVolchok DenysKuzmenko OleksandraThe purpose of this paper is to represent inner air temperature calculation algorithm provided that interior space is formed by several building envelopes which transmit thermal losses. The chosen external wall includes an area with damaged structural layers. We examine one-dimensional thermal transfer between hot (inner) and cold (outside) space in steady-state conditions. The derived equation allows calculating the estimated inner temperature of the air taking into consideration the various combination of building envelopes on condition that one of them is damaged.https://doi.org/10.1051/e3sconf/20183201019 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Petrenko Viktor Dikarev Kostiantyn Volchok Denys Kuzmenko Oleksandra |
spellingShingle |
Petrenko Viktor Dikarev Kostiantyn Volchok Denys Kuzmenko Oleksandra Evaluation of indoor temperature for various building envelopes damaged E3S Web of Conferences |
author_facet |
Petrenko Viktor Dikarev Kostiantyn Volchok Denys Kuzmenko Oleksandra |
author_sort |
Petrenko Viktor |
title |
Evaluation of indoor temperature for various building envelopes damaged |
title_short |
Evaluation of indoor temperature for various building envelopes damaged |
title_full |
Evaluation of indoor temperature for various building envelopes damaged |
title_fullStr |
Evaluation of indoor temperature for various building envelopes damaged |
title_full_unstemmed |
Evaluation of indoor temperature for various building envelopes damaged |
title_sort |
evaluation of indoor temperature for various building envelopes damaged |
publisher |
EDP Sciences |
series |
E3S Web of Conferences |
issn |
2267-1242 |
publishDate |
2018-01-01 |
description |
The purpose of this paper is to represent inner air temperature calculation algorithm provided that interior space is formed by several building envelopes which transmit thermal losses. The chosen external wall includes an area with damaged structural layers. We examine one-dimensional thermal transfer between hot (inner) and cold (outside) space in steady-state conditions. The derived equation allows calculating the estimated inner temperature of the air taking into consideration the various combination of building envelopes on condition that one of them is damaged. |
url |
https://doi.org/10.1051/e3sconf/20183201019 |
work_keys_str_mv |
AT petrenkoviktor evaluationofindoortemperatureforvariousbuildingenvelopesdamaged AT dikarevkostiantyn evaluationofindoortemperatureforvariousbuildingenvelopesdamaged AT volchokdenys evaluationofindoortemperatureforvariousbuildingenvelopesdamaged AT kuzmenkooleksandra evaluationofindoortemperatureforvariousbuildingenvelopesdamaged |
_version_ |
1724311927522328576 |