The comparison of gains prescribed for digital behind-the-ear hearing aids using the manufacturer-specific and conventional prescriptive formulas

Background and Aim: There are several prescriptive formulas for covering a variety of hearing loss, each of which applies relatively different amplifications at different frequencies. This study aims to compare the gains prescribed for digital behind-the-ear (BTE) hearing aids by the Desired Sensat...

Full description

Bibliographic Details
Main Authors: Shahin Shyekhaghaei, Seyyed Jalal Sameni, Nariman Rahbar
Format: Article
Language:English
Published: Tehran University of Medical Sciences 2021-04-01
Series:Auditory and Vestibular Research
Subjects:
Online Access:https://avr.tums.ac.ir/index.php/avr/article/view/902
id doaj-6a542ed5c8e347698e11c97e03b937af
record_format Article
spelling doaj-6a542ed5c8e347698e11c97e03b937af2021-09-11T04:13:42ZengTehran University of Medical SciencesAuditory and Vestibular Research2423-480X2021-04-0130210.18502/avr.v30i2.6097902The comparison of gains prescribed for digital behind-the-ear hearing aids using the manufacturer-specific and conventional prescriptive formulasShahin Shyekhaghaei0Seyyed Jalal Sameni1Nariman Rahbar2Department of Audiology, School of Rehabilitation Sciences, Iran University of Medical Sciences, Tehran, IranDepartment of Audiology, School of Rehabilitation Sciences, Iran University of Medical Sciences, Tehran, IranDepartment of Audiology, School of Rehabilitation Sciences, Iran University of Medical Sciences, Tehran, Iran Background and Aim: There are several prescriptive formulas for covering a variety of hearing loss, each of which applies relatively different amplifications at different frequencies. This study aims to compare the gains prescribed for digital behind-the-ear (BTE) hearing aids by the Desired Sensation Level Multi-Stage [Input/Output] (DSLm[I/O]), National Acoustic Laboratories-non linear2 (NAL-NL2) and manufacturer-specific formulas at different levels of input intensity. Methods: The gain values in 12-channel BTE hearing aids prepared from four companies (Oticon, Phonak, ReSound and Siemens) were measured at three levels of input intensity (45, 65, and 85 dB SPL) and at a frequency range of 250−8000 Hz for two moderately severe flat and mild sloping to severe hearing losses by using the DSLm[I/O], NAL-NL2 and manufacturer-specific formulas in the Frye FP35 test box. Results: There was no significant difference between the four selected hearing aids in terms of prescribed gain values using the prescriptive formulas (p > 0.05). Conclusion: The DSLm[I/O] formula prescribes higher gain in the 12-channel BTE hearing aids from Oticon, Phonak and Siemens companies at all input intensities and frequencies for moderately severe flat and mild sloping to severe hearing losses compared to the NAL-NL2 formula and manufacturer-specific formulas (Voice Ali­gned Compression (VAC), Adaptive Phonak, Connexx Fit and audiogram+). https://avr.tums.ac.ir/index.php/avr/article/view/902National acoustic laboratories-non linear2desired sensation level multi-stage [input/output]gainfrequencyintensity levels
collection DOAJ
language English
format Article
sources DOAJ
author Shahin Shyekhaghaei
Seyyed Jalal Sameni
Nariman Rahbar
spellingShingle Shahin Shyekhaghaei
Seyyed Jalal Sameni
Nariman Rahbar
The comparison of gains prescribed for digital behind-the-ear hearing aids using the manufacturer-specific and conventional prescriptive formulas
Auditory and Vestibular Research
National acoustic laboratories-non linear2
desired sensation level multi-stage [input/output]
gain
frequency
intensity levels
author_facet Shahin Shyekhaghaei
Seyyed Jalal Sameni
Nariman Rahbar
author_sort Shahin Shyekhaghaei
title The comparison of gains prescribed for digital behind-the-ear hearing aids using the manufacturer-specific and conventional prescriptive formulas
title_short The comparison of gains prescribed for digital behind-the-ear hearing aids using the manufacturer-specific and conventional prescriptive formulas
title_full The comparison of gains prescribed for digital behind-the-ear hearing aids using the manufacturer-specific and conventional prescriptive formulas
title_fullStr The comparison of gains prescribed for digital behind-the-ear hearing aids using the manufacturer-specific and conventional prescriptive formulas
title_full_unstemmed The comparison of gains prescribed for digital behind-the-ear hearing aids using the manufacturer-specific and conventional prescriptive formulas
title_sort comparison of gains prescribed for digital behind-the-ear hearing aids using the manufacturer-specific and conventional prescriptive formulas
publisher Tehran University of Medical Sciences
series Auditory and Vestibular Research
issn 2423-480X
publishDate 2021-04-01
description Background and Aim: There are several prescriptive formulas for covering a variety of hearing loss, each of which applies relatively different amplifications at different frequencies. This study aims to compare the gains prescribed for digital behind-the-ear (BTE) hearing aids by the Desired Sensation Level Multi-Stage [Input/Output] (DSLm[I/O]), National Acoustic Laboratories-non linear2 (NAL-NL2) and manufacturer-specific formulas at different levels of input intensity. Methods: The gain values in 12-channel BTE hearing aids prepared from four companies (Oticon, Phonak, ReSound and Siemens) were measured at three levels of input intensity (45, 65, and 85 dB SPL) and at a frequency range of 250−8000 Hz for two moderately severe flat and mild sloping to severe hearing losses by using the DSLm[I/O], NAL-NL2 and manufacturer-specific formulas in the Frye FP35 test box. Results: There was no significant difference between the four selected hearing aids in terms of prescribed gain values using the prescriptive formulas (p > 0.05). Conclusion: The DSLm[I/O] formula prescribes higher gain in the 12-channel BTE hearing aids from Oticon, Phonak and Siemens companies at all input intensities and frequencies for moderately severe flat and mild sloping to severe hearing losses compared to the NAL-NL2 formula and manufacturer-specific formulas (Voice Ali­gned Compression (VAC), Adaptive Phonak, Connexx Fit and audiogram+).
topic National acoustic laboratories-non linear2
desired sensation level multi-stage [input/output]
gain
frequency
intensity levels
url https://avr.tums.ac.ir/index.php/avr/article/view/902
work_keys_str_mv AT shahinshyekhaghaei thecomparisonofgainsprescribedfordigitalbehindtheearhearingaidsusingthemanufacturerspecificandconventionalprescriptiveformulas
AT seyyedjalalsameni thecomparisonofgainsprescribedfordigitalbehindtheearhearingaidsusingthemanufacturerspecificandconventionalprescriptiveformulas
AT narimanrahbar thecomparisonofgainsprescribedfordigitalbehindtheearhearingaidsusingthemanufacturerspecificandconventionalprescriptiveformulas
AT shahinshyekhaghaei comparisonofgainsprescribedfordigitalbehindtheearhearingaidsusingthemanufacturerspecificandconventionalprescriptiveformulas
AT seyyedjalalsameni comparisonofgainsprescribedfordigitalbehindtheearhearingaidsusingthemanufacturerspecificandconventionalprescriptiveformulas
AT narimanrahbar comparisonofgainsprescribedfordigitalbehindtheearhearingaidsusingthemanufacturerspecificandconventionalprescriptiveformulas
_version_ 1717757399061757952