The comparison of gains prescribed for digital behind-the-ear hearing aids using the manufacturer-specific and conventional prescriptive formulas
Background and Aim: There are several prescriptive formulas for covering a variety of hearing loss, each of which applies relatively different amplifications at different frequencies. This study aims to compare the gains prescribed for digital behind-the-ear (BTE) hearing aids by the Desired Sensat...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Tehran University of Medical Sciences
2021-04-01
|
Series: | Auditory and Vestibular Research |
Subjects: | |
Online Access: | https://avr.tums.ac.ir/index.php/avr/article/view/902 |
id |
doaj-6a542ed5c8e347698e11c97e03b937af |
---|---|
record_format |
Article |
spelling |
doaj-6a542ed5c8e347698e11c97e03b937af2021-09-11T04:13:42ZengTehran University of Medical SciencesAuditory and Vestibular Research2423-480X2021-04-0130210.18502/avr.v30i2.6097902The comparison of gains prescribed for digital behind-the-ear hearing aids using the manufacturer-specific and conventional prescriptive formulasShahin Shyekhaghaei0Seyyed Jalal Sameni1Nariman Rahbar2Department of Audiology, School of Rehabilitation Sciences, Iran University of Medical Sciences, Tehran, IranDepartment of Audiology, School of Rehabilitation Sciences, Iran University of Medical Sciences, Tehran, IranDepartment of Audiology, School of Rehabilitation Sciences, Iran University of Medical Sciences, Tehran, Iran Background and Aim: There are several prescriptive formulas for covering a variety of hearing loss, each of which applies relatively different amplifications at different frequencies. This study aims to compare the gains prescribed for digital behind-the-ear (BTE) hearing aids by the Desired Sensation Level Multi-Stage [Input/Output] (DSLm[I/O]), National Acoustic Laboratories-non linear2 (NAL-NL2) and manufacturer-specific formulas at different levels of input intensity. Methods: The gain values in 12-channel BTE hearing aids prepared from four companies (Oticon, Phonak, ReSound and Siemens) were measured at three levels of input intensity (45, 65, and 85 dB SPL) and at a frequency range of 250−8000 Hz for two moderately severe flat and mild sloping to severe hearing losses by using the DSLm[I/O], NAL-NL2 and manufacturer-specific formulas in the Frye FP35 test box. Results: There was no significant difference between the four selected hearing aids in terms of prescribed gain values using the prescriptive formulas (p > 0.05). Conclusion: The DSLm[I/O] formula prescribes higher gain in the 12-channel BTE hearing aids from Oticon, Phonak and Siemens companies at all input intensities and frequencies for moderately severe flat and mild sloping to severe hearing losses compared to the NAL-NL2 formula and manufacturer-specific formulas (Voice Aligned Compression (VAC), Adaptive Phonak, Connexx Fit and audiogram+). https://avr.tums.ac.ir/index.php/avr/article/view/902National acoustic laboratories-non linear2desired sensation level multi-stage [input/output]gainfrequencyintensity levels |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Shahin Shyekhaghaei Seyyed Jalal Sameni Nariman Rahbar |
spellingShingle |
Shahin Shyekhaghaei Seyyed Jalal Sameni Nariman Rahbar The comparison of gains prescribed for digital behind-the-ear hearing aids using the manufacturer-specific and conventional prescriptive formulas Auditory and Vestibular Research National acoustic laboratories-non linear2 desired sensation level multi-stage [input/output] gain frequency intensity levels |
author_facet |
Shahin Shyekhaghaei Seyyed Jalal Sameni Nariman Rahbar |
author_sort |
Shahin Shyekhaghaei |
title |
The comparison of gains prescribed for digital behind-the-ear hearing aids using the manufacturer-specific and conventional prescriptive formulas |
title_short |
The comparison of gains prescribed for digital behind-the-ear hearing aids using the manufacturer-specific and conventional prescriptive formulas |
title_full |
The comparison of gains prescribed for digital behind-the-ear hearing aids using the manufacturer-specific and conventional prescriptive formulas |
title_fullStr |
The comparison of gains prescribed for digital behind-the-ear hearing aids using the manufacturer-specific and conventional prescriptive formulas |
title_full_unstemmed |
The comparison of gains prescribed for digital behind-the-ear hearing aids using the manufacturer-specific and conventional prescriptive formulas |
title_sort |
comparison of gains prescribed for digital behind-the-ear hearing aids using the manufacturer-specific and conventional prescriptive formulas |
publisher |
Tehran University of Medical Sciences |
series |
Auditory and Vestibular Research |
issn |
2423-480X |
publishDate |
2021-04-01 |
description |
Background and Aim: There are several prescriptive formulas for covering a variety of hearing loss, each of which applies relatively different amplifications at different frequencies. This study aims to compare the gains prescribed for digital behind-the-ear (BTE) hearing aids by the Desired Sensation Level Multi-Stage [Input/Output] (DSLm[I/O]), National Acoustic Laboratories-non linear2 (NAL-NL2) and manufacturer-specific formulas at different levels of input intensity.
Methods: The gain values in 12-channel BTE hearing aids prepared from four companies (Oticon, Phonak, ReSound and Siemens) were measured at three levels of input intensity (45, 65, and 85 dB SPL) and at a frequency range of 250−8000 Hz for two moderately severe flat and mild sloping to severe hearing losses by using the DSLm[I/O], NAL-NL2 and manufacturer-specific formulas in the Frye FP35 test box.
Results: There was no significant difference between the four selected hearing aids in terms of prescribed gain values using the prescriptive formulas (p > 0.05).
Conclusion: The DSLm[I/O] formula prescribes higher gain in the 12-channel BTE hearing aids from Oticon, Phonak and Siemens companies at all input intensities and frequencies for moderately severe flat and mild sloping to severe hearing losses compared to the NAL-NL2 formula and manufacturer-specific formulas (Voice Aligned Compression (VAC), Adaptive Phonak, Connexx Fit and audiogram+).
|
topic |
National acoustic laboratories-non linear2 desired sensation level multi-stage [input/output] gain frequency intensity levels |
url |
https://avr.tums.ac.ir/index.php/avr/article/view/902 |
work_keys_str_mv |
AT shahinshyekhaghaei thecomparisonofgainsprescribedfordigitalbehindtheearhearingaidsusingthemanufacturerspecificandconventionalprescriptiveformulas AT seyyedjalalsameni thecomparisonofgainsprescribedfordigitalbehindtheearhearingaidsusingthemanufacturerspecificandconventionalprescriptiveformulas AT narimanrahbar thecomparisonofgainsprescribedfordigitalbehindtheearhearingaidsusingthemanufacturerspecificandconventionalprescriptiveformulas AT shahinshyekhaghaei comparisonofgainsprescribedfordigitalbehindtheearhearingaidsusingthemanufacturerspecificandconventionalprescriptiveformulas AT seyyedjalalsameni comparisonofgainsprescribedfordigitalbehindtheearhearingaidsusingthemanufacturerspecificandconventionalprescriptiveformulas AT narimanrahbar comparisonofgainsprescribedfordigitalbehindtheearhearingaidsusingthemanufacturerspecificandconventionalprescriptiveformulas |
_version_ |
1717757399061757952 |