A case of 25 gauge vitrectomy for malignant glaucoma with microphthalmos

Masami Nakajima, Yusuke Hara, Yoshio Yamazaki Department of Ophthalmology, Division of Visual Science, Nihon University School of Medicine, Tokyo, Japan Abstract: We report the first case report of pars plana lensectomy (PPL) and pars plana vitrectomy using a 25 gauge vitrectomy system for microphth...

Full description

Bibliographic Details
Main Authors: Nakajima M, Hara Y, Yamazaki Y
Format: Article
Language:English
Published: Dove Medical Press 2013-05-01
Series:Clinical Ophthalmology
Online Access:http://www.dovepress.com/a-case-of-25-gauge-vitrectomy-for-malignant-glaucoma-with-microphthalm-a13221
id doaj-69da3a5e69e14f91a6196ae2a53c06c9
record_format Article
spelling doaj-69da3a5e69e14f91a6196ae2a53c06c92020-11-24T22:56:09ZengDove Medical PressClinical Ophthalmology1177-54671177-54832013-05-012013default10271029A case of 25 gauge vitrectomy for malignant glaucoma with microphthalmosNakajima MHara YYamazaki YMasami Nakajima, Yusuke Hara, Yoshio Yamazaki Department of Ophthalmology, Division of Visual Science, Nihon University School of Medicine, Tokyo, Japan Abstract: We report the first case report of pars plana lensectomy (PPL) and pars plana vitrectomy using a 25 gauge vitrectomy system for microphthalmos. Results: A 45-year-old woman reported repeated pain in her left eye, despite the use of medications. Ultrasound biomicroscopy revealed a narrow angle and thickened sclera. The lens and the iris showed anterior displacement with a flattening of the ciliary body. The axial length was 15.16 mm in the right eye and 15.04 mm in the left eye. She was diagnosed with a malignant glaucoma with microphthalmos. The patient underwent PPL and pars plana vitrectomy, using a 25 gauge vitrectomy system. The intraocular pressure was well controlled after surgery without medication. Conclusion: We considered the PPL and 25 gauge vitrectomy effective in microphthalmos when performed safely. Keywords: microphthalmos, aqueous misdirection, malignant glaucoma, ultrasound biomicroscopy, 25 gauge vitrectomyhttp://www.dovepress.com/a-case-of-25-gauge-vitrectomy-for-malignant-glaucoma-with-microphthalm-a13221
collection DOAJ
language English
format Article
sources DOAJ
author Nakajima M
Hara Y
Yamazaki Y
spellingShingle Nakajima M
Hara Y
Yamazaki Y
A case of 25 gauge vitrectomy for malignant glaucoma with microphthalmos
Clinical Ophthalmology
author_facet Nakajima M
Hara Y
Yamazaki Y
author_sort Nakajima M
title A case of 25 gauge vitrectomy for malignant glaucoma with microphthalmos
title_short A case of 25 gauge vitrectomy for malignant glaucoma with microphthalmos
title_full A case of 25 gauge vitrectomy for malignant glaucoma with microphthalmos
title_fullStr A case of 25 gauge vitrectomy for malignant glaucoma with microphthalmos
title_full_unstemmed A case of 25 gauge vitrectomy for malignant glaucoma with microphthalmos
title_sort case of 25 gauge vitrectomy for malignant glaucoma with microphthalmos
publisher Dove Medical Press
series Clinical Ophthalmology
issn 1177-5467
1177-5483
publishDate 2013-05-01
description Masami Nakajima, Yusuke Hara, Yoshio Yamazaki Department of Ophthalmology, Division of Visual Science, Nihon University School of Medicine, Tokyo, Japan Abstract: We report the first case report of pars plana lensectomy (PPL) and pars plana vitrectomy using a 25 gauge vitrectomy system for microphthalmos. Results: A 45-year-old woman reported repeated pain in her left eye, despite the use of medications. Ultrasound biomicroscopy revealed a narrow angle and thickened sclera. The lens and the iris showed anterior displacement with a flattening of the ciliary body. The axial length was 15.16 mm in the right eye and 15.04 mm in the left eye. She was diagnosed with a malignant glaucoma with microphthalmos. The patient underwent PPL and pars plana vitrectomy, using a 25 gauge vitrectomy system. The intraocular pressure was well controlled after surgery without medication. Conclusion: We considered the PPL and 25 gauge vitrectomy effective in microphthalmos when performed safely. Keywords: microphthalmos, aqueous misdirection, malignant glaucoma, ultrasound biomicroscopy, 25 gauge vitrectomy
url http://www.dovepress.com/a-case-of-25-gauge-vitrectomy-for-malignant-glaucoma-with-microphthalm-a13221
work_keys_str_mv AT nakajimam acaseof25gaugevitrectomyformalignantglaucomawithmicrophthalmos
AT haray acaseof25gaugevitrectomyformalignantglaucomawithmicrophthalmos
AT yamazakiy acaseof25gaugevitrectomyformalignantglaucomawithmicrophthalmos
AT nakajimam caseof25gaugevitrectomyformalignantglaucomawithmicrophthalmos
AT haray caseof25gaugevitrectomyformalignantglaucomawithmicrophthalmos
AT yamazakiy caseof25gaugevitrectomyformalignantglaucomawithmicrophthalmos
_version_ 1725654551128702976