Osteonecrosis with the use of polymethylmethacrylate cement for hip replacement: thermal-induced damage evidenced in vivo by decreased osteocyte viability

Thermal damage to host bone is a possible source of compromise of fixation in patients undergoing cemented total hip replacement (THR). Data on the subject to date are derived from mathematical modelling powered by animal studies. The aim of this study was to assess the effect of cement thickness on...

Full description

Bibliographic Details
Main Authors: MR Whitehouse, NS Atwal, M Pabbruwe, AW Blom, GC Bannister
Format: Article
Language:English
Published: AO Research Institute Davos 2014-01-01
Series:European Cells & Materials
Online Access:http://www.ecmjournal.org/papers/vol027/pdf/v027a05.pdf
id doaj-69d5e25cd3f2463eb85686adede417bc
record_format Article
spelling doaj-69d5e25cd3f2463eb85686adede417bc2020-11-24T23:30:18Zeng AO Research Institute DavosEuropean Cells & Materials1473-22622014-01-0127506310.22203/eCM.v027a05Osteonecrosis with the use of polymethylmethacrylate cement for hip replacement: thermal-induced damage evidenced in vivo by decreased osteocyte viabilityMR Whitehouse0NS AtwalM PabbruweAW BlomGC BannisterMusculoskeletal Research Unit, Avon Orthopaedic Centre (Lower Level), Southmead Hospital, Westbury-on-Trym, Bristol, BS10 5NB, UKThermal damage to host bone is a possible source of compromise of fixation in patients undergoing cemented total hip replacement (THR). Data on the subject to date are derived from mathematical modelling powered by animal studies. The aim of this study was to assess the effect of cement thickness on osteocyte viability in a population of patients undergoing cemented THR. An in vivo model was designed and validated by means of a finite element analysis. During standard hip joint replacement in 14 patients, the femoral necks were exposed before final resection to the heat of a curing cement mantle equivalent to 2.5 (Group 1) or 5 mm (Group 2) in vivo in the cemented acetabulum. Matched controls were collected for each patient. Osteocyte counts and viability were assessed by means of haematoxylin and eosin (H&E) stain and lactate dehydrogenase (LDH) assay. Ex vivo experiments were performed to determine the extent of thermal insult. H&E staining proved unreliable for assessing thermal insult in the short term. The LDH assay was reliable and demonstrated a significant reduction in osteocyte viability to a depth of 2.19 mm in group 1 and 9.19 mm in group 2. There was a significant difference between the groups at all depths. The ex vivo experiments revealed thermoclines indicating that host bone in the population undergoing cemented THR is more sensitive to the thermal insult delivered by curing polymethylmethacrylate cement than previously believed. This thermal insult may weaken the fixation between bone and cement and contribute towards aseptic loosening, the commonest cause of failure of THRs.http://www.ecmjournal.org/papers/vol027/pdf/v027a05.pdf
collection DOAJ
language English
format Article
sources DOAJ
author MR Whitehouse
NS Atwal
M Pabbruwe
AW Blom
GC Bannister
spellingShingle MR Whitehouse
NS Atwal
M Pabbruwe
AW Blom
GC Bannister
Osteonecrosis with the use of polymethylmethacrylate cement for hip replacement: thermal-induced damage evidenced in vivo by decreased osteocyte viability
European Cells & Materials
author_facet MR Whitehouse
NS Atwal
M Pabbruwe
AW Blom
GC Bannister
author_sort MR Whitehouse
title Osteonecrosis with the use of polymethylmethacrylate cement for hip replacement: thermal-induced damage evidenced in vivo by decreased osteocyte viability
title_short Osteonecrosis with the use of polymethylmethacrylate cement for hip replacement: thermal-induced damage evidenced in vivo by decreased osteocyte viability
title_full Osteonecrosis with the use of polymethylmethacrylate cement for hip replacement: thermal-induced damage evidenced in vivo by decreased osteocyte viability
title_fullStr Osteonecrosis with the use of polymethylmethacrylate cement for hip replacement: thermal-induced damage evidenced in vivo by decreased osteocyte viability
title_full_unstemmed Osteonecrosis with the use of polymethylmethacrylate cement for hip replacement: thermal-induced damage evidenced in vivo by decreased osteocyte viability
title_sort osteonecrosis with the use of polymethylmethacrylate cement for hip replacement: thermal-induced damage evidenced in vivo by decreased osteocyte viability
publisher AO Research Institute Davos
series European Cells & Materials
issn 1473-2262
publishDate 2014-01-01
description Thermal damage to host bone is a possible source of compromise of fixation in patients undergoing cemented total hip replacement (THR). Data on the subject to date are derived from mathematical modelling powered by animal studies. The aim of this study was to assess the effect of cement thickness on osteocyte viability in a population of patients undergoing cemented THR. An in vivo model was designed and validated by means of a finite element analysis. During standard hip joint replacement in 14 patients, the femoral necks were exposed before final resection to the heat of a curing cement mantle equivalent to 2.5 (Group 1) or 5 mm (Group 2) in vivo in the cemented acetabulum. Matched controls were collected for each patient. Osteocyte counts and viability were assessed by means of haematoxylin and eosin (H&E) stain and lactate dehydrogenase (LDH) assay. Ex vivo experiments were performed to determine the extent of thermal insult. H&E staining proved unreliable for assessing thermal insult in the short term. The LDH assay was reliable and demonstrated a significant reduction in osteocyte viability to a depth of 2.19 mm in group 1 and 9.19 mm in group 2. There was a significant difference between the groups at all depths. The ex vivo experiments revealed thermoclines indicating that host bone in the population undergoing cemented THR is more sensitive to the thermal insult delivered by curing polymethylmethacrylate cement than previously believed. This thermal insult may weaken the fixation between bone and cement and contribute towards aseptic loosening, the commonest cause of failure of THRs.
url http://www.ecmjournal.org/papers/vol027/pdf/v027a05.pdf
work_keys_str_mv AT mrwhitehouse osteonecrosiswiththeuseofpolymethylmethacrylatecementforhipreplacementthermalinduceddamageevidencedinvivobydecreasedosteocyteviability
AT nsatwal osteonecrosiswiththeuseofpolymethylmethacrylatecementforhipreplacementthermalinduceddamageevidencedinvivobydecreasedosteocyteviability
AT mpabbruwe osteonecrosiswiththeuseofpolymethylmethacrylatecementforhipreplacementthermalinduceddamageevidencedinvivobydecreasedosteocyteviability
AT awblom osteonecrosiswiththeuseofpolymethylmethacrylatecementforhipreplacementthermalinduceddamageevidencedinvivobydecreasedosteocyteviability
AT gcbannister osteonecrosiswiththeuseofpolymethylmethacrylatecementforhipreplacementthermalinduceddamageevidencedinvivobydecreasedosteocyteviability
_version_ 1725541865088876544