THE INVESTIGATION OF THE INTERACTION OF THE IMPLANTABLE ROTARY BLOOD PUMP AND THE LEFT VENTRICLE ON THE MOCK CIRCULATION SYSTEM
We analyzed the dynamics of the interaction of rotary pump, connected to the scheme «the left ventricle – aor- ta», and left ventricle in norms and heart failure, using data obtained on the mock circulatory system. Adverse pumping states such as suction and regurgitation can be detected. These limit...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | Russian |
Published: |
Federal Research Center of Transplantology and Artificial Organs named after V.I.Shumakov
2010-06-01
|
Series: | Vestnik Transplantologii i Iskusstvennyh Organov |
Subjects: | |
Online Access: | https://journal.transpl.ru/vtio/article/view/332 |
id |
doaj-69c5dadacfa54fc4abb72ec24eb6756a |
---|---|
record_format |
Article |
spelling |
doaj-69c5dadacfa54fc4abb72ec24eb6756a2021-07-29T09:08:28ZrusFederal Research Center of Transplantology and Artificial Organs named after V.I.Shumakov Vestnik Transplantologii i Iskusstvennyh Organov1995-11912010-06-011239410010.15825/1995-1191-2010-3-94-100275THE INVESTIGATION OF THE INTERACTION OF THE IMPLANTABLE ROTARY BLOOD PUMP AND THE LEFT VENTRICLE ON THE MOCK CIRCULATION SYSTEME. G. Konysheva0G. P. Itkin1K. N. Dozorov2V. L. Kudinov3D. V. Shumakov4Academician V.I. Shumakov Federal Research Center of Transplantology and Artificial Organs, MoscowAcademician V.I. Shumakov Federal Research Center of Transplantology and Artificial Organs, MoscowAcademician V.I. Shumakov Federal Research Center of Transplantology and Artificial Organs, MoscowAcademician V.I. Shumakov Federal Research Center of Transplantology and Artificial Organs, MoscowAcademician V.I. Shumakov Federal Research Center of Transplantology and Artificial Organs, MoscowWe analyzed the dynamics of the interaction of rotary pump, connected to the scheme «the left ventricle – aor- ta», and left ventricle in norms and heart failure, using data obtained on the mock circulatory system. Adverse pumping states such as suction and regurgitation can be detected. These limits depend on the degree of cardiac failure, which confirms the need to control the speed of rotation of the impeller in the range of the cardiac failure from pathology to normal. It has been shown that the pulsating pressure at the inlet of the pump modulates the flow of the pump, making it a pulsating, what positively affects on the dynamics of cardiac output.https://journal.transpl.ru/vtio/article/view/332assisted circulationrotary blood pumpcardiac failuremock circulationnonpulsatile pumpimplantable centrifugal and axial pumpimpeller rate of rotation. |
collection |
DOAJ |
language |
Russian |
format |
Article |
sources |
DOAJ |
author |
E. G. Konysheva G. P. Itkin K. N. Dozorov V. L. Kudinov D. V. Shumakov |
spellingShingle |
E. G. Konysheva G. P. Itkin K. N. Dozorov V. L. Kudinov D. V. Shumakov THE INVESTIGATION OF THE INTERACTION OF THE IMPLANTABLE ROTARY BLOOD PUMP AND THE LEFT VENTRICLE ON THE MOCK CIRCULATION SYSTEM Vestnik Transplantologii i Iskusstvennyh Organov assisted circulation rotary blood pump cardiac failure mock circulation nonpulsatile pump implantable centrifugal and axial pump impeller rate of rotation. |
author_facet |
E. G. Konysheva G. P. Itkin K. N. Dozorov V. L. Kudinov D. V. Shumakov |
author_sort |
E. G. Konysheva |
title |
THE INVESTIGATION OF THE INTERACTION OF THE IMPLANTABLE ROTARY BLOOD PUMP AND THE LEFT VENTRICLE ON THE MOCK CIRCULATION SYSTEM |
title_short |
THE INVESTIGATION OF THE INTERACTION OF THE IMPLANTABLE ROTARY BLOOD PUMP AND THE LEFT VENTRICLE ON THE MOCK CIRCULATION SYSTEM |
title_full |
THE INVESTIGATION OF THE INTERACTION OF THE IMPLANTABLE ROTARY BLOOD PUMP AND THE LEFT VENTRICLE ON THE MOCK CIRCULATION SYSTEM |
title_fullStr |
THE INVESTIGATION OF THE INTERACTION OF THE IMPLANTABLE ROTARY BLOOD PUMP AND THE LEFT VENTRICLE ON THE MOCK CIRCULATION SYSTEM |
title_full_unstemmed |
THE INVESTIGATION OF THE INTERACTION OF THE IMPLANTABLE ROTARY BLOOD PUMP AND THE LEFT VENTRICLE ON THE MOCK CIRCULATION SYSTEM |
title_sort |
investigation of the interaction of the implantable rotary blood pump and the left ventricle on the mock circulation system |
publisher |
Federal Research Center of Transplantology and Artificial Organs named after V.I.Shumakov |
series |
Vestnik Transplantologii i Iskusstvennyh Organov |
issn |
1995-1191 |
publishDate |
2010-06-01 |
description |
We analyzed the dynamics of the interaction of rotary pump, connected to the scheme «the left ventricle – aor- ta», and left ventricle in norms and heart failure, using data obtained on the mock circulatory system. Adverse pumping states such as suction and regurgitation can be detected. These limits depend on the degree of cardiac failure, which confirms the need to control the speed of rotation of the impeller in the range of the cardiac failure from pathology to normal. It has been shown that the pulsating pressure at the inlet of the pump modulates the flow of the pump, making it a pulsating, what positively affects on the dynamics of cardiac output. |
topic |
assisted circulation rotary blood pump cardiac failure mock circulation nonpulsatile pump implantable centrifugal and axial pump impeller rate of rotation. |
url |
https://journal.transpl.ru/vtio/article/view/332 |
work_keys_str_mv |
AT egkonysheva theinvestigationoftheinteractionoftheimplantablerotarybloodpumpandtheleftventricleonthemockcirculationsystem AT gpitkin theinvestigationoftheinteractionoftheimplantablerotarybloodpumpandtheleftventricleonthemockcirculationsystem AT kndozorov theinvestigationoftheinteractionoftheimplantablerotarybloodpumpandtheleftventricleonthemockcirculationsystem AT vlkudinov theinvestigationoftheinteractionoftheimplantablerotarybloodpumpandtheleftventricleonthemockcirculationsystem AT dvshumakov theinvestigationoftheinteractionoftheimplantablerotarybloodpumpandtheleftventricleonthemockcirculationsystem AT egkonysheva investigationoftheinteractionoftheimplantablerotarybloodpumpandtheleftventricleonthemockcirculationsystem AT gpitkin investigationoftheinteractionoftheimplantablerotarybloodpumpandtheleftventricleonthemockcirculationsystem AT kndozorov investigationoftheinteractionoftheimplantablerotarybloodpumpandtheleftventricleonthemockcirculationsystem AT vlkudinov investigationoftheinteractionoftheimplantablerotarybloodpumpandtheleftventricleonthemockcirculationsystem AT dvshumakov investigationoftheinteractionoftheimplantablerotarybloodpumpandtheleftventricleonthemockcirculationsystem |
_version_ |
1721249277282353152 |