Tolerability of the Oscar 2 ambulatory blood pressure monitor among research participants: a cross-sectional repeated measures study

<p>Abstract</p> <p>Background</p> <p>Ambulatory blood pressure monitoring (ABPM) is increasingly used to measure blood pressure (BP) in research studies. We examined ease of use, comfort, degree of disturbance, reported adverse effects, factors associated with poor tole...

Full description

Bibliographic Details
Main Authors: Hinderliter Alan L, Lingley Kara, Viera Anthony J
Format: Article
Language:English
Published: BMC 2011-04-01
Series:BMC Medical Research Methodology
Online Access:http://www.biomedcentral.com/1471-2288/11/59
id doaj-699adeaed213453fb4df30cc70d47db8
record_format Article
spelling doaj-699adeaed213453fb4df30cc70d47db82020-11-24T23:18:02ZengBMCBMC Medical Research Methodology1471-22882011-04-011115910.1186/1471-2288-11-59Tolerability of the Oscar 2 ambulatory blood pressure monitor among research participants: a cross-sectional repeated measures studyHinderliter Alan LLingley KaraViera Anthony J<p>Abstract</p> <p>Background</p> <p>Ambulatory blood pressure monitoring (ABPM) is increasingly used to measure blood pressure (BP) in research studies. We examined ease of use, comfort, degree of disturbance, reported adverse effects, factors associated with poor tolerability, and association of poor tolerability with data acquisition of 24-hour ABPM using the Oscar 2 monitor in the research setting.</p> <p>Methods</p> <p>Sixty adults participating in a research study of people with a history of borderline clinic BP reported on their experience with ABPM on two occasions one week apart. Poor tolerability was operationalized as an overall score at or above the 75th percentile using responses to questions adapted from a previously developed questionnaire. In addition to descriptive statistics (means for responses to Likert-scaled "0 to 10" questions and proportions for Yes/No questions), we examined reproducibility of poor tolerability as well as associations with poor tolerability and whether poor tolerability was associated with removal of the monitor or inadequate number of BP measurements.</p> <p>Results</p> <p>The mean ambulatory BP of participants by an initial ABPM session was 148/87 mm Hg. After wearing the monitor the first time, the degree to which the monitor was felt to be cumbersome ranged from a mean of 3.0 to 3.8, depending on whether at work, home, driving, or other times. The most bother was interference with normal sleeping pattern (mean 4.2). Wearers found the monitor straightforward to use (mean 7.5). Nearly 67% reported that the monitor woke them after falling asleep, and 8.6% removed it at some point during the night. Reported adverse effects included pain (32%), skin irritation (37%), and bruising (7%). Those categorized as having poor tolerability (kappa = 0.5 between sessions, p = 0.0003) were more likely to report being in fair/poor health (75% vs 22%, p = 0.01) and have elevated 24-hour BP average (systolic: 28% vs 17%, p = 0.56; diastolic: 30% vs 17%, p = 0.37). They were also more likely to remove the monitor and have inadequate numbers of measurements.</p> <p>Conclusions</p> <p>The Oscar 2 ABPM device is straightforward to use but can interfere with sleep. Commonly reported adverse effects include pain, skin irritation, and bruising. Those who tolerate the monitor poorly are more likely to report being in fair or poor health and to remove it, particularly at night.</p> http://www.biomedcentral.com/1471-2288/11/59
collection DOAJ
language English
format Article
sources DOAJ
author Hinderliter Alan L
Lingley Kara
Viera Anthony J
spellingShingle Hinderliter Alan L
Lingley Kara
Viera Anthony J
Tolerability of the Oscar 2 ambulatory blood pressure monitor among research participants: a cross-sectional repeated measures study
BMC Medical Research Methodology
author_facet Hinderliter Alan L
Lingley Kara
Viera Anthony J
author_sort Hinderliter Alan L
title Tolerability of the Oscar 2 ambulatory blood pressure monitor among research participants: a cross-sectional repeated measures study
title_short Tolerability of the Oscar 2 ambulatory blood pressure monitor among research participants: a cross-sectional repeated measures study
title_full Tolerability of the Oscar 2 ambulatory blood pressure monitor among research participants: a cross-sectional repeated measures study
title_fullStr Tolerability of the Oscar 2 ambulatory blood pressure monitor among research participants: a cross-sectional repeated measures study
title_full_unstemmed Tolerability of the Oscar 2 ambulatory blood pressure monitor among research participants: a cross-sectional repeated measures study
title_sort tolerability of the oscar 2 ambulatory blood pressure monitor among research participants: a cross-sectional repeated measures study
publisher BMC
series BMC Medical Research Methodology
issn 1471-2288
publishDate 2011-04-01
description <p>Abstract</p> <p>Background</p> <p>Ambulatory blood pressure monitoring (ABPM) is increasingly used to measure blood pressure (BP) in research studies. We examined ease of use, comfort, degree of disturbance, reported adverse effects, factors associated with poor tolerability, and association of poor tolerability with data acquisition of 24-hour ABPM using the Oscar 2 monitor in the research setting.</p> <p>Methods</p> <p>Sixty adults participating in a research study of people with a history of borderline clinic BP reported on their experience with ABPM on two occasions one week apart. Poor tolerability was operationalized as an overall score at or above the 75th percentile using responses to questions adapted from a previously developed questionnaire. In addition to descriptive statistics (means for responses to Likert-scaled "0 to 10" questions and proportions for Yes/No questions), we examined reproducibility of poor tolerability as well as associations with poor tolerability and whether poor tolerability was associated with removal of the monitor or inadequate number of BP measurements.</p> <p>Results</p> <p>The mean ambulatory BP of participants by an initial ABPM session was 148/87 mm Hg. After wearing the monitor the first time, the degree to which the monitor was felt to be cumbersome ranged from a mean of 3.0 to 3.8, depending on whether at work, home, driving, or other times. The most bother was interference with normal sleeping pattern (mean 4.2). Wearers found the monitor straightforward to use (mean 7.5). Nearly 67% reported that the monitor woke them after falling asleep, and 8.6% removed it at some point during the night. Reported adverse effects included pain (32%), skin irritation (37%), and bruising (7%). Those categorized as having poor tolerability (kappa = 0.5 between sessions, p = 0.0003) were more likely to report being in fair/poor health (75% vs 22%, p = 0.01) and have elevated 24-hour BP average (systolic: 28% vs 17%, p = 0.56; diastolic: 30% vs 17%, p = 0.37). They were also more likely to remove the monitor and have inadequate numbers of measurements.</p> <p>Conclusions</p> <p>The Oscar 2 ABPM device is straightforward to use but can interfere with sleep. Commonly reported adverse effects include pain, skin irritation, and bruising. Those who tolerate the monitor poorly are more likely to report being in fair or poor health and to remove it, particularly at night.</p>
url http://www.biomedcentral.com/1471-2288/11/59
work_keys_str_mv AT hinderliteralanl tolerabilityoftheoscar2ambulatorybloodpressuremonitoramongresearchparticipantsacrosssectionalrepeatedmeasuresstudy
AT lingleykara tolerabilityoftheoscar2ambulatorybloodpressuremonitoramongresearchparticipantsacrosssectionalrepeatedmeasuresstudy
AT vieraanthonyj tolerabilityoftheoscar2ambulatorybloodpressuremonitoramongresearchparticipantsacrosssectionalrepeatedmeasuresstudy
_version_ 1725582124984041472