Erythrocyte Sedimentation Rate Measurement Using as a Rapid Alternative to the Westergren Method

Introduction: Erythrocyte sedimentation rate (ESR) remains as one of the most reliable tests in clinical practices. Yet its use is time consuming and requires a large blood sample. The aim of this study was assessing a faster and reliable method of ESR estimation. Methods: An ESR estimation metho...

Full description

Bibliographic Details
Main Authors: Reza Hashemi, Alireza Majidi, Hassan Motamed, Afshin Amini, Fares Najari, Ali Tabatabaey
Format: Article
Language:English
Published: Shahid Beheshti University of Medical Sciences 2018-12-01
Series:Archives of Academic Emergency Medicine
Subjects:
Online Access:https://journals.sbmu.ac.ir/aaem/index.php/AAEM/article/view/265
id doaj-6996be0d52964b81b81c6d8a3f35452d
record_format Article
spelling doaj-6996be0d52964b81b81c6d8a3f35452d2020-11-25T03:12:33ZengShahid Beheshti University of Medical SciencesArchives of Academic Emergency Medicine2645-49042018-12-013210.22037/aaem.v3i2.265Erythrocyte Sedimentation Rate Measurement Using as a Rapid Alternative to the Westergren MethodReza Hashemi0Alireza Majidi1Hassan Motamed2Afshin Amini3Fares Najari4Ali Tabatabaey5Department of Internal Medicine, Shohadaye Tajrish Hospital, Shahid Beheshti University of Medical Sciences, Tehran, IranDepartment of Emergency Medicine, Shohadaye Tajrish Hospital, Shahid Beheshti University of Medical Sciences, Tehran, IranDepartment of Emergency Medicine, Ahvaz Jundishapour University of Medical Sciences, Ahvaz, IranDepartment of Emergency Medicine, Imam Hossein Hospital, Shahid Beheshti University of Medical Sciences, Tehran, IranDepartment of Forensic Medicine, Shahid Beheshti University of Medical Sciences, Tehran, IranDepartment of Emergency Medicine, Shahid Beheshti Hospital, Qom University of Medical Sciences, Qom, IranIntroduction: Erythrocyte sedimentation rate (ESR) remains as one of the most reliable tests in clinical practices. Yet its use is time consuming and requires a large blood sample. The aim of this study was assessing a faster and reliable method of ESR estimation. Methods: An ESR estimation method was described and performed on 108 patients using capillary tube (micro ESR) and capillary peripheral blood. Micro ESR results at different intervals were measured and compared with Westergren ESR (conventional ESR) estimation by Pearson and Spearman’s coefficients. A regression equation was derived to predict conventional ESR values based on micro ESR results. The agreement of two measurements was demonstrated using the Bland-Altman plot. Results: Micro ESR results at 20 minutes showed the earliest close correlation with conventional ESR results at one hour (0.99). The presented regression equation was able to closely predict ESR values (r2 = 0.974) and the Bland-Altman plot showed an acceptable agreement between converted and conventional ESR measurements. Conclusion: Using capillary tube and capillary blood sample (micro ESR) appears to be a faster, cheaper, more reliable, and precise tool for ESR measurement in the ED. The results have acceptable correlation with conventional ESR, especially at 20 minutes of measurement.https://journals.sbmu.ac.ir/aaem/index.php/AAEM/article/view/265Blood Sedimentationmethodserythrocytescapillary tubingemergency medicine
collection DOAJ
language English
format Article
sources DOAJ
author Reza Hashemi
Alireza Majidi
Hassan Motamed
Afshin Amini
Fares Najari
Ali Tabatabaey
spellingShingle Reza Hashemi
Alireza Majidi
Hassan Motamed
Afshin Amini
Fares Najari
Ali Tabatabaey
Erythrocyte Sedimentation Rate Measurement Using as a Rapid Alternative to the Westergren Method
Archives of Academic Emergency Medicine
Blood Sedimentation
methods
erythrocytes
capillary tubing
emergency medicine
author_facet Reza Hashemi
Alireza Majidi
Hassan Motamed
Afshin Amini
Fares Najari
Ali Tabatabaey
author_sort Reza Hashemi
title Erythrocyte Sedimentation Rate Measurement Using as a Rapid Alternative to the Westergren Method
title_short Erythrocyte Sedimentation Rate Measurement Using as a Rapid Alternative to the Westergren Method
title_full Erythrocyte Sedimentation Rate Measurement Using as a Rapid Alternative to the Westergren Method
title_fullStr Erythrocyte Sedimentation Rate Measurement Using as a Rapid Alternative to the Westergren Method
title_full_unstemmed Erythrocyte Sedimentation Rate Measurement Using as a Rapid Alternative to the Westergren Method
title_sort erythrocyte sedimentation rate measurement using as a rapid alternative to the westergren method
publisher Shahid Beheshti University of Medical Sciences
series Archives of Academic Emergency Medicine
issn 2645-4904
publishDate 2018-12-01
description Introduction: Erythrocyte sedimentation rate (ESR) remains as one of the most reliable tests in clinical practices. Yet its use is time consuming and requires a large blood sample. The aim of this study was assessing a faster and reliable method of ESR estimation. Methods: An ESR estimation method was described and performed on 108 patients using capillary tube (micro ESR) and capillary peripheral blood. Micro ESR results at different intervals were measured and compared with Westergren ESR (conventional ESR) estimation by Pearson and Spearman’s coefficients. A regression equation was derived to predict conventional ESR values based on micro ESR results. The agreement of two measurements was demonstrated using the Bland-Altman plot. Results: Micro ESR results at 20 minutes showed the earliest close correlation with conventional ESR results at one hour (0.99). The presented regression equation was able to closely predict ESR values (r2 = 0.974) and the Bland-Altman plot showed an acceptable agreement between converted and conventional ESR measurements. Conclusion: Using capillary tube and capillary blood sample (micro ESR) appears to be a faster, cheaper, more reliable, and precise tool for ESR measurement in the ED. The results have acceptable correlation with conventional ESR, especially at 20 minutes of measurement.
topic Blood Sedimentation
methods
erythrocytes
capillary tubing
emergency medicine
url https://journals.sbmu.ac.ir/aaem/index.php/AAEM/article/view/265
work_keys_str_mv AT rezahashemi erythrocytesedimentationratemeasurementusingasarapidalternativetothewestergrenmethod
AT alirezamajidi erythrocytesedimentationratemeasurementusingasarapidalternativetothewestergrenmethod
AT hassanmotamed erythrocytesedimentationratemeasurementusingasarapidalternativetothewestergrenmethod
AT afshinamini erythrocytesedimentationratemeasurementusingasarapidalternativetothewestergrenmethod
AT faresnajari erythrocytesedimentationratemeasurementusingasarapidalternativetothewestergrenmethod
AT alitabatabaey erythrocytesedimentationratemeasurementusingasarapidalternativetothewestergrenmethod
_version_ 1724649896405893120